CNC-Step T-Rex Series Manuel utilisateur

Quick Start Guide
T-Rex Series
CNC-STEP e.K. ▪Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 2
Support: +49 (0)2831/91021-50
15.01.2015
T-Rex Series
Short Description
This Quick Start Guide will help you with the initial start-up of the machine.
It also includes optional accessory that is connected directly to the machine or control.
For more detailed information please refer to the individual manuals.

Quick Start Guide
T-Rex Series
CNC-STEP e.K. ▪Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 3
Support: +49 (0)2831/91021-50
15.01.2015
CONTENTS
1CONNECTORS AND CABLES ON THE MACHINE.....................................................5
1.1 Connection Panel Machine......................................................................................................5
1.2 Mini XLR Jack.........................................................................................................................6
1.3 Connection Panel Z-axis..........................................................................................................7
1.4 Noga Minimum lubrication system ........................................................................................8
1.4.1 control box with solenoid valve...........................................................................................8
2CONNECTIONS TO THE ZERO-3 STEPPER MOTOR CONTROLLER......................9
2.1 Front side ..................................................................................................................................9
2.2 Back side..................................................................................................................................10
3CONNECTING THE MACHINE TO THE ZERO-3 CONTROL....................................11
4CONNECTION POSSIBILITY OF A 4TH AXIS...........................................................12
5CONNECTION OPTIONS OF OPTIONAL ACCESSORIES.......................................13
5.1 Overview Connection and power supply via Zero-3 control..............................................13
5.2 Milling motors ........................................................................................................................14
5.3 Noga spray cooling with solenoid valve................................................................................14
5.4 Inverter and HF spindles.......................................................................................................15
5.5 Granitograv and laser engraving unit..................................................................................15
6SOFTWARE INSTALLATION.....................................................................................16
6.1 WinPCNC ...............................................................................................................................16
6.1.1 Installation.........................................................................................................................17
6.1.2 Connecting the computer to the Zero-3 control.................................................................17
6.1.3 Configuration.....................................................................................................................18
6.1.4 Determination of the LPT interface (Light and Economy) ...............................................18
6.1.5 Determination of the COM interface (Professional) .........................................................20
6.1.6 Entry of the determined interface / port address in WinPCNC.........................................21
6.1.7 Entry LPT2 port (only Economy)......................................................................................21
6.1.8 check the efficiency...........................................................................................................22
6.1.9 Load and save machine parameters...................................................................................23
6.2 ConstruCam 3D......................................................................................................................24
6.2.1 Installation.........................................................................................................................24
6.2.2 Interaction with WinPCNC ...............................................................................................24

Quick Start Guide
T-Rex Series
CNC-STEP e.K. ▪Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 4
Support: +49 (0)2831/91021-50
15.01.2015
6.3 Other Software .......................................................................................................................25
7CUSTOMER SERVICE ...............................................................................................26

Quick Start Guide
T-Rex Series
CNC-STEP e.K. ▪Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 5
Support: +49 (0)2831/91021-50
15.01.2015
Connection Panel Machine
1Connectors and cables on the machine
1.1 Connection Panel Machine
D-Sub 9pol. ST
Control line ST
D-Sub 15pol. C
Tangential Tools (to Connection Panel Z-axis)
Neutrik 4pol. X
Motor connection cable X-axis
Neutrik 4pol. Y
Motor connection cable Y-axis
Neutrik 4pol. Z
Motor connection cable Z-axis
Hirschmann 7pol.
HF-Spindle (to Connection Panel Z-axis)
230V Plug
230V Socket Connection Panel Z-axis
Touchprobe
Length Sensor

Quick Start Guide
T-Rex Series
CNC-STEP e.K. ▪Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 6
Support: +49 (0)2831/91021-50
15.01.2015
1.2 Mini XLR Jack
The miniXLR jack provides the option of connecting extensions without additional hardware.
For example:
Tool length control, Security housings with door switch
3D Buttons
Note:
Concomitant use of this socket and a 4th axis, such as a rotation axis or tangential knife, the
connectivity is limited because both the miniXLR socket and the reference switch the 4th axis are
found via the PIN15 of the LPT port.
For this combination, we have a solution. To do so, please contact our customer service.
Mini-XLR-jack

Quick Start Guide
T-Rex Series
CNC-STEP e.K. ▪Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 7
Support: +49 (0)2831/91021-50
15.01.2015
Panel Z-axis
1.3 Connection Panel Z-axis
At the Z-axis various connectivity options for optional accessories are available.
Note socket:
This socket can be connected to an external power supply, or alternative directly to the machine
control Zero-3.
Then there is the possibility to turn off the power by software. (see chapter 2.2)
EOT-2
Milling Motor 230V
HF-Spindle
TCM-3
TCT-1
Tangential tools
230V / max. 8A
Connect to Zero-3
Controller !
(see chapter 2.2)

Quick Start Guide
T-Rex Series
CNC-STEP e.K. ▪Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 8
Support: +49 (0)2831/91021-50
15.01.2015
Noga-Minimalmengenschmierung
1.4 Noga Minimum lubrication system
The Noga minimal lubrication system allows the processing of materials which make cooling
necessary. For the operation of a compressor is required with min. 2.5 bar.
1 – Coolant container 2 – control valve
3 – Air connection Z axis 4 – adjustable nozzle
5 – Manual On / Off (with the hex screw you can adjust the amount of air)
1.4.1 control box with solenoid valve
The control box for the Noga system is located on the back of the machine. The system is
automatically switched on and off via software, when connected to the Zero-3 Control.
1 – 230V power supply (at Rel.2 of Zero-3)
2 – Air output to Z axis
3 - silencer
4 – Air connection (min. 2.5 bar)

Quick Start Guide
T-Rex Series
CNC-STEP e.K. ▪Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 9
Support: +49 (0)2831/91021-50
15.01.2015
2Connections to the Zero-3 stepper motor controlle r
2.1 Front side
7 8
1 2 3 4 5 6 9
Front side Overview
1Connector D-Sub 9pol. for motor X1
2Connector D-Sub 9pol. for motor X2 (not use for T-Rex)
3Connector D-Sub 9pol. for motor Y
4Connector D-Sub 9pol. for motor Z
5Connector D-Sub 15pol. for 4th axis (Rotary axis / tangential knife)
6Connector D-Sub 9pol. for Control line ST
7Emergency-stop-button
8Power-button
9Status-LEDs
Zero-3 Front Side

Quick Start Guide
T-Rex Series
CNC-STEP e.K. ▪Siemensstrasse 13-15 ▪ 47608 Geldern ▪ Germany
Page 10
Support: +49 (0)2831/91021-50
15.01.2015
2.2 Back side
5 6
1 2 3 4 7*
Overview back side
1 power supply (115-240V input voltage)
2 LPT1 input
3 LPT2 input
4 LPT2 output (0-10Volt Edition)
5 Socket 1 (115-240V depending on input voltage - switchable via relay 1)
6 Socket 2 (115-240V depending on input voltage - switched via relay 2)
7 Ground (* only High-Z series > 03/2015)
Note on the sockets 1 + 2:
The two sockets are with two relays switchable. Thus, the consumer connected to it can be switched
on and off via software.
This guarantees also that the power supply is interrupted at faults and in emergency case.
The maximum power consumption per outlet may not exceed 8A.
The current consumption of the two sockets together may not exceed 13.5A.
Zero-3 Back Side
Autres manuels pour T-Rex Series
1
Table des matières
Autres manuels CNC-Step Outils électriques