CLIVET ELFOControl2 Guide rapide

Installation, configuration and use manual
ELFOControl2
M0CZ40B12-10 16-12-2013

Dear Customer,
We congratulate you on choosing an ELFOSystem product, the air conditio-
ning system at annual cycle that offers the possibility in a sole system of
meeting all the heating, conditioning and domestic hot water needs.
Clivet is being working for years to offer systems able to assure the maxi-
mum comfort for long time with high reliability, efficiency , quality and sa-
fety. The target of the company is to offer advanced systems, that assure
the best comfort, reduce the energy consumption, the installation and main-
tenance costs for all the life-cycle of the system.
With this manual, we want to give you information that are useful in all the
phases: from the reception, to the installation and use until the disposal so
that a system so advanced offers the best procedure of installation and use.
Best regards and have a nice reading !
CLIVET Spa

TABLE OF CONTENTS
INSTRUCTIONS FOR USER
Main functions ................................................................................................................................................ pag.5
Display ............................................................................................................................................................ pag.6
Switching on and off the system...................................................................................................................... pag.7
Heating / cooling / automatic mode ................................................................................................................. pag.8
Adjusting date and hour ................................................................................................................................. pag.9
Heat pump ...................................................................................................................................................... pag.10
Domestic hot water ........................................................................................................................................ pag.14
Fresh air: ELFOFresh2.................................................................................................................................... pag.16
"Away from home " management................................................................................................................... pag.18
Area programming ........................................................................................................................................ pag.19
Alarms ............................................................................................................................................................ pag.23
Modification of the program name................................................................................................................... pag.24
System setting ................................................................................................................................................ pag.26
INSTRUCTIONS FOR THE INSTALLER
Elfocontrol2 ..................................................................................................................................................... pag.28
Bus RS485...................................................................................................................................................... pag.30
System diagrams ........................................................................................................................................... pag 31
Electrical connections
Unit for the production of thermal energy ........................................................................................................ pag.33
Unit for fresh air .............................................................................................................................................. pag.37
Terminali ambiente ......................................................................................................................................... pag.39
Ambient terminals .......................................................................................................................................... pag.41
Module of radiant areas ................................................................................................................................. pag.42
Addressing
Keyboard unit .................................................................................................................................................. pag.47
Thermostats ................................................................................................................................................... pag.51
Modules ......................................................................................................................................................... pag.54
Configuration
System component configuration .................................................................................................................... pag.61
Auto-configuration .......................................................................................................................................... pag.67
Status component system .............................................................................................................................. pag.69
Erros: RS485 network ..................................................................................................................................... pag.73
Disposal ......................................................................................................................................................... pag.73
Parameters of the components ....................................................................................................................... pag.74
Modbus TCP / IPfor domotic system .............................................................................................................. pag.75


Page 5
Main functions of the System.
Heat pump for:
• hot and cold water for radiators, radiant panels and fan convectors;
• domestic hot water (DHW).
ELFOFresh for:
• renew air by heating or cooling it;
• control the ambient humidity;
• air-condition in seasons when the heat pump, terminals and radiant
panels or radiators are not necessary;
• renew and filter air without heating or cooling it (ventilation only).
Production of domestic hot water, for which it is possible to set:
• the maximum temperature of water inside the storage tank;
• time bands where water is taken to storage maximum temperature
or kept at a maintenance temperature;
• production only with solar panels;
• production with boiler integrated.
Area Divisions:
• the house can be divided into homogeneous areas depending on
the type of use (day or night area, up to a limit of 12 areas);
• a different hour schedule can be combined with each area, either
from other areas or from day to day of the week;
programs are common to all areas
• in one area, three operation modes can be set, comfort, economic
or off;
for comfort and eco modes, temperature and humidity set points
can be configured together with the type of ventilation;
• an area can be forced in the required operation mode for a certain
period, "stopping" temporarily the ongoing program .
Setpoint:
• each area has a comfort setpoint (optimal comfort, greater
consumption) and an economic set (medium comfort, minimum
consumption);
the economic set is calculated adding (in summer) or subtracting
(in winter) a set value to the comfort set point;
• the set point can be modified manually, any time .
Programs:
• a program can be selected among 7 available and modified
according to the requirements;
• the time schedule sets the operation mode (comfort, economic or
off) for each hour of the day and each day of the week;
• new programs can be added.
Domotic systems connection
MAIN FUNCTIONS
Indications for the use
Keep this manual in an accessible place for the operator.
In case of breakdown or malfunction:
• immediately deactivate the system.
• contact an assistance service centre authorized by the manifac-
turer.
• use original spares parts only
Ask the installer to be prepared on:
• start-up / shutdown;
• set-point and scheduling personalization;
• maintenance;
• what to do / what not to do in case of breakdown.

Page 6
Heat pump
1 supply water temperature
2 return water temperature
3 % use of the compressor
4 status
5 components found in the system:
Radiators, Fan coils, Radiant panels,
6 primary pump
DISPLAY
ELFOFresh2: (max. four units installed)
1 supply air temperature
2 return air temperature
3 status of the compressor: on/off
4 ELFOFresh2on / off
5 operation status:
heating / cooling / ventilation off
Production of domestic hot water:
1 upper storage temperature
2 lower storage temperature
3 solar water temperature
4 solar status (active/inactive)
System areas:
• schedule
Switching on and off the system
"Away" function
Return to the main display without saving modifications
(displayed in the subsequent menus)
Return to the previous display without saving modifications
(displayed in the subsequent menus)
Help
Alarms
System settings
Only qualified personnel is allowed to access
Save modifications, return to the previous display
(displayed in the subsequent menus)
1
24
1
2
3
4
5
1
2
3
1
2
3
4
5
6
4
Information displayed:
1 status of the system:
heating / cooling / automatic / off
2 date/hour
3 Domotic control:
green = connected system
gray = system configuration (not connected);
parameter not enabled
4 Outdoor air temperature
3

Page 7
SYSTEM
START-UP AND SWITCH-OFF
1 - The system can be:
• on
• off
• off until day / off until time a
3 - Start up the system
4 - Switch off the system
5 - Switch off the system until day / hour:
at the due time, the system returns to the status
previously set.
6 - Set the SYSTEM START-UP date
go to display n. 8
7 - Set the SYSTEM START-UP date
go to display n. 9
Confirm the modification
2
3
4
5
67
8
9
select 2
select 6
1
select 7

Page 8
SYSTEM
Select:
2 - Heating only
3 - Cooling only
4 - Automatic
switches from heating to
cooling automatically, depending on the outdoor and indoor
temperature detected
mode enabled only if ELFOFresh2, is present
CHANGE MODE
1 - Operation of the system.
Confirm the modification
1
2
3
4
select 1

Page 9
SYSTEM
ADJUSTING DATE AND HOUR
Set date and hour to synchronise the system operation.
Settings:
•Automatic
(do not activate this setting)
•Set date
•Select time zone
•Set hour
•Use H24 format
•Select date format
To exit drag area "3" downwards
1
2
select 1
select 2
select 3
3
select 4
4

Page 10
HEAT PUMP
SET HEAT PUMP OPERATION
Information displayed:
• supply water temperature
• return water temperature
• % capacity of the compressor
• operation status (heating/cooling/off)
• components found in the system (radiators, fan coils and
radiant panels) and relative status (enabled / excluded).
2 - Automatic operation:
The heat pump is used to produce both air-conditioning system
water and domestic hot water.
3 - For domestic hot water only:
The heat pump is used only to produce domestic hot water.
4 - Deactivate the heat pump:
The heat pump is switched off
5 - Distribution:
Displays the components in the system and the water temperature.
The operation of single components of the system can be enabled or
excluded:
select 6, 7 or 8 to Exclude / Enable
Example
6 - Radiators:
Excluded
7 - Radiant panels:
Enabled
8 - Terminals:
Enabled
2
3
4
5
6
1
select 1
select 5
78