Clean PH200 Manuel utilisateur

CLEAN PH200/ PH500 pH/ mV/ ORP/ Ion
Versatile Water Analysis Meter
CLEAN INSTRUMENTS CO. LTD
2F No.140, Zhongxiao St., Zhonghe Dist., New Taipei City ,Taiwan
www.cleaninst.com
E-mail: [email protected]

www.cleaninst.com
MODE
ESC
CAL
INFO
MI
SET
ENT
HOLD
MR
PH200
MODE
ESC
CAL
INFO MI
SET ENT
HOLD
MR
PH500
pH/ mV/ ORP/ Ion/ Temp
CLEAN PH200/PH500
Versatile Water Analysis Meter

TABLE OF CONTENTS
01
02
03
04
07
08
08
09
09
09
10
11
12
12
13
13
14
15
15
15
16
16
17
19
20
21
22
23
1 Preface
2 Basic Operation
3 Key Panel
4 Appearance
5.1 Technical Specifications
5.2 Model and Function
5.3 Browse the parameter
5.4 Set UP
5.4.1 pH set up
P01 pH Standard Solution
P02 Manual Temperature setting
P03 Temperature Offset setting
P04 Auto Lock Function setting
P05 Prompt tone setting (optional)
P06 Auto Power Off Setting
P07 Clearing Memory Function
P08 Reverting to Factory Default Setting
5.4.2 ORP set up
5.4.3 Ion set up
P01 Measuring unit setting
P02 Calibration point setting
P03 Ionic valence setting
5.5 Calibration Mode
5.6 Measurement Mode
5.7 Storage of measuring Data
5.8 Browse on Setting Parameters
5.9 Appendix
GENERAL INFORMATION
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

01

02
BNC Temperature
+
-
M
SET
ENT
HOLD
MR
PH200
+
-

03

04
1 Battery power
2 S- Stable. If twinkling, means unstable.
3 CAL – Calibration
4. SET- Setup display
5 HOLD- Auto lock
6 °C °F - Temperature
7 ATC - Automatic Temperature Compensation
8 PH、mV、ORP、Ion、ppm、mg/L- Measurement mode、Unit of Measurement
9 STD - Standard solutions
10 mV - Zero drift、mV indicator or Ion sensor slope
11 % - Uncalibrated meter is 0% and “%”twinkling. When sensor slope is ≤65%, “%”twinkling
Display
4. Appearance
①
②
③④ ⑤
⑥
⑦
⑧
⑧
⑩
⑪
⑨

05
Sensor
Manual Temperature setting
Temperature offset setting
Automatic Temp. Compensation
Prompt tone setting
Electrode slope
Auto lock
Auto off
no stored data
Clear data
Offset
Menu item
Buffer Solution
Buffer kinds
Reset to factory defaults
Save Data
On
Off
No
Yes
Temperature value Over
Temperature value Under
Full Data Storage
Measuring Value Over
Measuring Value Under
Battery
Error
Ion concentration unit selection
Ion calibration Points
Ionic valence
10 of the fourth power: 10000
10 of the fifth power: 100000
Display Character Table
ATC

06
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
One key to switch among pH, mV, ORP, Ion measuring modes.
pH value, mV value, Temperature value with screen display simultaneously, humanized design.
°C °F optional
Four sets with 11 points buffer combination, covering global standards including US, EU, CN, JP.
Two points ORP calibration
Ion concentration measuring range: 0.000-99999mg/L
Large LCD, with high luminance LED backlight.
One key to auto calibration: Zero offset、Electrode offset、ensure the accuracy
One key to browse the setting parameters, including Electrode zero offset, sensor slope and all
set parameters.
Prompt tone after measurement readings stable(Optional)
HOLD Auto Lock function
Temperature offset adjust
200 sets of measuring data storage
Auto power off if no operations in 10 minutes. (Optional)
2*1.5V 7AAA batteries. Long battery life span
CLEAN PH200/PH500 series products with precise and practical design concept: simple operation,
powerful functions, complete measuring parameters, wide measurement range. Four sets with 11
points buffer combination, one key to calibrate and auto buffer recognition. Clear and easy
understandable operation interface, excellent anti-interference, precise measuring, convenient
to operate, combined with the high luminance LED backlight, CLEAN PH200/PH500 is your
professional choice, a reliable partner in Lab, factory, and routine measuring in school.
CLEAN PH200 / PH500 pH/ mV/ ORP/ Ion/ Temp
Versatile Water Analysis Meter

07
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Power supply
B1
B2
B3
B4
Environment
Memory
Dimensions
Weight
-2.00 ~ 20.00 pH
0.01 pH
±0.01 pH
-2000~2000 mV
0.1mV ( -999 ~999mV ), 1 mV ( <-999 mV or >999 mV )
± 1 mV
0.000-99999mg/L, ppm
0.001,0.01,0.1,1 mg/L, ppm
1%+1LSD(1 valence), 2%+1LSD(2 valence), 3%+1LSD(3 valence)
-40.0-125.0℃(-40.0-257.0°F)
0.1°C, 0.1°F
+0.2°C, 0.1°F
2*1.5V 7AAA batteries
1.68, 4.01, 7.00, 10.01 (US)
2.00, 4.01, 7.00, 9.21, 11.00 (EU)
1.68, 4.00, 6.86, 9.18, 12.46 (CN)
1.68,4.01, 6.86, 9.18 (JP)
-5 °C~60 °C;Relative humidity﹤90%
200 sets
94*190*35mm (W*L*H)
250g
pH
ORP
Ion
Temperat
ure
Battery
pH Buffer
Kinds
Others
5.1 Technical Specifications
Transformer 100 ~220V
140*210*35mm (W*L*H)
650g
PH500PH200
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Clean Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur