10
User Menu Parameters
50
-10
0,8
-2.0
Hold T + H together for 3 se onds to enter menu
-Use T /H buttons to hoose parameter.
-Use U/D buttons to hange parameter values.
-Hold T + H together for 3 se onds to save hanges.
hhi: high humidity alarm.
Started : set value +10
Delay time: 20 minutes
Notifi ation: Alr 5
Voi e alarm : continuous
hlo: low humidity alarm.
Started : set value -10
Delay time: 20 minutes
Notifi ation: Alr 6
Voi e alarm : intermittently
f)thi: high temperature alarm.
Started : set value + 0,8
Delay time: 2 minutes
Notifi ation: Alr 1/3
Voi e alarm : continuous
f)tlo: low temperature alarm.
Started : set value - 2.0
Delay time: 30 minutes
Notifi ation: Alr 2/4
Voi e alarm : intermittently
tco: temperature calibration value.
CAUTION! tCo is a critical parameter . Changing this can
results in chick looses. Plsease use qualified and
calibrated glass or electronic thermometers for
calibrationpurpose. Check temperature values regularly.
h o: humidity alibration value.
CAUTION! hCo is a critical parameter. Changing this can
results in chick looses. Please use qualified and
calibrated glass or electronic thermometers for
calibration purpose. Check humidity values regularly.
th
18
28
10
off
0.0
0.0
US2: USB onne ted devi e
no : no onne ted devi e
th : se ond sensor onne ted ( room/ alibration)
ıot: iot module onne ted
Notifi ation: Alr 15 (usb onne tion error)
below parameters a tive if Us2 is sele ted “th”
f)rtl: second sensor low temperature alarm.
Started : below 18 C / 65 F
Delay time: no
Notifi ation: Alr 10
Voi e alarm : intermittently
f)rth: second sensor high temperature alarm.
Started : over 28 C / 83 F
Delay time: no
Notifi ation: Alr 9
Voi e alarm : intermittently
rhl: second sensor low humidity alarm.
Started : below 10 RH
Delay time: no
Notifi ation: Alr 14
Voi e alarm : intermittently
rhh: second sensor high humidity alarm.
Started : over 85 RH
Delay time: no
Notifi ation: Alr 13
Voi e alarm : intermittently
rAt: second sensor temperature alarm activation.
On: alarms a tivated
Off: alarms dea tivated
rAt: second sensor humidity alarm activation.
On: alarms a tivated
Off: alarms dea tivated