CEStronics Omega active 247510F Manuel

OMEGA ACTIVE Access Point
247510F
Fitting and Operating
Instructions
Translated fitting and
operating instructions
version 1.24, 08/2012

Preface
2 Access Point
Preface
These Fitting and Operating Instructions will help you fit and
use the Access Point
as intended,
safely, and
advantageously.
Any person who
fits,
operates, or
disposes of
this Access Point must have read and understood the entire
contents of these Fitting and Operating Instructions.
These Fitting and Operating Instructions should be kept near
the Access Point at all times.
Notes on the layout
In these Fitting and Operating Instructions, various elements
are highlighted with defined layout features so you can identify
at a glance whether a passage contains
standard text,
a list, or
individual steps in a sequence of actions.
Notes highlighted with this symbol contain additional
information on the efficient use of the Access Point.

Contents
Access Point 3
Contents
Preface .......................................................................... 2
Notes on the layout ....................................................... 2
For your safety .............................................................. 5
Basic safety instructions................................................. 5
Explanation of the safety notes ....................................... 7
Intended use ................................................................ 8
Remarks ...................................................................... 8
Manufacturer ................................................................ 8
Service ........................................................................ 8
Introduction .................................................................. 9
Description ................................................................... 9
Components of a wireless system...................................11
OMEGA ACTIVE system components ...............................12
Scope of delivery..........................................................13
Unpacking the Access Point ...........................................14
Connections.................................................................15
RF ranges....................................................................16
Fitting the Access Point ............................................... 19
Fitting the additional antenna ..................................... 28
Scope of delivery..........................................................28

Contents
4 Access Point
Trouble shooting ......................................................... 31
Maintenance ................................................................ 34
Spare Parts.................................................................. 34
Disposal....................................................................... 34
Technical data ............................................................. 35
Glossary ...................................................................... 37
Notes on the manufacturer's warranty ........................ 39

For your safety
Access Point 5
For your safety
Basic safety instructions
Observe all warnings and notes in these Fitting and Operating
Instructions. Always keep these Fitting and Operating
Instructions near the Access Point.
To prevent danger to life and limb, the following safety
instructions must be observed:
Danger of explosion
Live parts of the Access Point may cause an explosion. Do not
use the Access Point in potentially explosive atmospheres.
Danger of suffocation
Never allow children to play with packaging material and/or
plastic bags. There is a risk that children pull them over their
head and suffocate.
Danger of poisoning
Always keep the locking cylinder out of the reach of children.
There is a risk that children swallow small parts such as
batteries or screws.
Danger of property damage
To prevent property damage, the following safety instructions
should be observed:
Always have repairs performed by properly qualified
personnel.
Only use accessories and spare parts recommended by
CEStronics.

For your safety
6 Access Point
Only use the proper tools to open the Access Point.
Do not drop the Access Point on the floor, on hard surfaces or
on hard objects.
Use surge arresters to avoid damage to your Access Point
through overvoltage, for example by lightning.
Protect the electronic components of the Access Point against
water and other liquids.
The Access Point contains highly sensitive electronic parts
that may be damaged or destroyed through static charges.
Do not disassemble the Access Point in rooms with built up
static charge. Ensure potential equalization when working on
the Access Point to remove any static charge.
Do not use the Access Point in corrosive atmospheres
(chlorine, ammonia, lime water).
Only use the Access Point in rooms in which the humidity
does not exceed 95 %.
Do not use the Access Point in rooms with a high level of dust
formation.
Do not use the Access Point near sources of heat.
Do not expose the Access Point to temperatures below 0 °C
or above +40 °C.
Danger of malfunctions
Do not cover the housing of the Access Point with any
metallic material.
Satisfy yourself when installing the Access Point that both the
Access Point and all other system components are in perfect
working order. Malfunctions of the Access Point and other
system components may compromise the functioning of the
entire system.
If necessary, use uninterrupted power supply (UPS) systems
to ensure an uninterrupted operation of your locking system.

For your safety
Access Point 7
Explanation of the safety notes
These Fitting and Operating Instructions include safety notes of
the following types:
CAUTION
CAUTION notes warn against hazards that
may result in slight or medium injuries.
ATTENTION
Notes warn against possible property or
environmental damage.

For your safety
8 Access Point
Intended use
The Access Point serves to transmit data between locking
cylinders and/or wall terminals and the control centre of your
OMEGA ACTIVE system. It is exclusively intended and may only
be used for that purpose.
Any other use is considered to be improper and may result in
property damage or even personal injury.
CEStronics GmbH does not accept any liability for any damage
resulting from improper use.
Remarks
This fitting and operating instructions are only valid for:
CEStronics OMEGA ACTIVE Access Point 247510F
Manufacturer
The manufacturer from the Access Point is:
CEStronicsGmbH
Friedrichstr. 243
42551 Velbert
Tel: +49 (0) 2051-204-0
Fax: +49 (0) 2051-204-105
www.ces.eu
Service
For support in case of service please contact your CEStronics
partner.

Introduction
Access Point 9
Introduction
Description
The Access Point is part of the OMEGA ACTIVE system. It
establishes the connection between the OMEGA ACTIVE locking
devices and the overall control centre via a radio frequency
(RF) link. This overall control centre is a commercial PC.
The Access Point is connected with the control centre via an
RJ45-Ethernet cable (10/100 Mbit). The Access Point is thus
the network interface of the system.
The desired access authorizations are created in the control
centre and transmitted via the Ethernet to the Access Points.
The Access Points then transmit the authorizations over the RF
link to the locking devices.
In return, the log data are retrieved from the cylinders and
then fed back to the control centre via the Ethernet.
The wide range of the Access Points allows a wireless
deployment of locking cylinders and wall terminals. No further
installation work on your doors is required.
If you use OMEGA ACTIVE locking media with a push-button,
you can use the push-button to control the relay contact in the
Access Point. The relay contact is directly controlled with this
button.
A wireless system always comprises a PC, the
OMEGA ACTIVE Client software, a number of Access
Points for data exchange and at least one locking
device.

Introduction
10 Access Point
Other features of the Access Point:
Integrated 868 MHz RF transceiver.
The maximum range for reading locking devices inside of
buildings is 25 m without and 40 m with the optional
additional antenna.
Power supply of the Access Point with the supplied power
pack. No other power supplies are permitted.
Two colour LEDs at the Ethernet connection for visual
signalization of data traffic.
Available accessories for the Access Point:
D-LAN™ adapter (System Powerline, to implement IP
networks using the 230 V power network). This option
makes it possible to transmit the network signal via the
230 V power network using suitable adapters. This means
that no separate network cables must be installed.
PoE (Power over Ethernet) adapter. To reduce the
installation expense and increase the failure prevention you
can supply the Access Point with power via the network
interface. This eliminates the need to use the plug-in power
supply.
Antenna retrofit kit to increase the range for reading locking
devices to a maximum of 40 m.
The stated reading ranges of 25 m, and 40 m
respectively, cannot be guaranteed as the reading
range depends on the local building conditions.
CEStronics recommends to have your building
situation checked by your professional CEStronics
partner.
For further information on the available options,
please contact your CEStronics partner.
Table des matières
Autres manuels CEStronics Point d'accès sans fil
Manuels Point d'accès sans fil populaires d'autres marques

D-Link
D-Link DWL-2100AP - AirPlus Xtreme G Manuel utilisateur

Ubiquiti
Ubiquiti NanoStation NSM2 Manuel utilisateur

Cisco
Cisco Aironet 1550 Series Manuel utilisateur

Aruba
Aruba IAP-335 Manuel utilisateur

Advantek Networks
Advantek Networks AWN-AP-54MR Manuel utilisateur

IP-COM
IP-COM AP355 Manuel utilisateur













