Cepex CMC-08-24 Manuel utilisateur

Electrically Operated Advanced
Computerized Irrigation Controller
Installation and Operating Manual
CMC- 08-24
AIN OFF
TEST /
ESET
TIME / DAY
UN
MANUAL
P OG AM
WEEKLY
CYCLIC
STA T
VALVES
DU ATION
VALVE
DU ATIONSTA T
FE TILIZE
SENSO
WATE
BUDGET
PROGRAM
A-B-C
INDEPENDENT
I
WEEKLY /
CYCLIC
EN
ES

Controls the operation of 1 to 24 valves + main valve or pump
Operates 24VAC electric valves
Sensor input
Weekly or cyclic irri ation pro rammin for a roup of valves
Independent weekly or cyclic irri ation pro rammin for
individual valves
Fertilization pro rammin of individual valves
Pro rammin for arden li htin system
Water bud et: optional percenta e modification of irri ation
duration
Irri ation duration from 1 minute up to 9 hours
Irri ation cycle from once daily to once every 30 days
Computerized manual operation of individual valves or valve
roups
Detection of short circuits. Circuit breaker identifies and overrides
a short in a valve, with visual warnin
Memory backup of pro ram for 20 years (batteries unnecessary)
Clock backup with 9V battery (not included)
Controller Features
EN

Installation Preparation
1. Adjusting irrigation controller to valves ..........................................................................................4
2. Manual-Mechanical Operation.....................................................................................................4
Installation and Wiring Instructions ........................................................................................................................................5
1. Controller installation..........................................................................................................6
2. Adding or Replacing 4- alve Module..............................................................................7
3. Connecting solenoid wires.............................................................................................................8
4. Connecting the controller to AC volthge source.........................................................................11
5. Sensor connection......................................................................................................................12
Programming the Irrigation Controller
1. General Information.....................................................................................................................................................................13
2. Setting current time and day of the week.........................................................................................................................14
Programming of valve-group irrigation (A, B, or C).........................................................................................15
1. Programming weekly irrigation...............................................................................................................................16
2. Programming cyclic irrigation...................................................................................................................................................18
3. Selecting valves for group A, B or C ................................................................................................................................19
4. Setting irrigation duration times ..........................................................................................................................20
Programming controller for Individual valve - Independent Program I
1. alve selection for Independent Program I...................................................................................................................21
2. Setting irrigation duration (Independent Program I)..........................................................................22
3. Irrigation by day of the week............................................................................................................................................23
4. Cyclic irrigation programming.......................................................................................................................................25
Advanced Programming
1. Fertilization supplement.............................................................................................................................................26
2. Relating sensor.........................................................................................................................................................................27
3. Garden lighting program.............................................................................................................................................28
4. Water budget..............................................................................................................................................................................29
5. Rain off.......................................................................................................................................................................................30
6. Manual ............................................................................................................................................................................................................31
7. Testing.......................................................................................................................................................................................32
8. RESET.......................................................................................................................................................................................32
CO TE TS
E

CONTENTS
Maintenance
1. Low battery warning.....................................................................................................33
2. No power warning.....................................................................................................................33
3. Filter................................................................................................................................................33
4. Water pressure...........................................................................................................................33
5. Troubleshooting-dete tion and repair................................................................................34
Accessories.........................................................................................................................................35
EN

4
Installation Preparation
1. Adjusting the Irrigation Controller to
the Valves. The irrigation controller is designed
to operate standard electrical valves of up to
24VAC 2.2 W. The valves are not supplied
with the controller.
1. Close the ain water valve.
2. Install valves in the irrigation syste .
A ain electrical valve can be installed at the
entrance to the irrigation syste . The ain
valve will opened auto atically when any valve
is opened, and will close auto atically with
the closing of the last valve.
The ain valve is shown on the display panel
and on the ter inal block by the letter M.
There is no need to progra the ain valve.
2. Mechanical Manual Operation
The irrigation valves ay be opened/closed
unrelated to the operation of the controller.
This ode is useful when irrigation is necessary
i ediately, and there is no ti e for operating
the controller.
The anual operating handle is located under
the solenoid.
1. To open the valve turn the handle counter-
clockwise
2. To close the valve turn the handle
clockwise
* When the electricity is turned on the valve
cannot be closed anually.
* To operate a valve with the controller, the
anually operated handle ust be in a auto
position .
ATTENTION !
Direct water flow according to the
water direction sy bol on the valve.
ATTENTION !
If there is a ain anual valve,
it should be opened anually.
HANDLE
HANDLE
HANDLE
OPEN AUTO
1
2
EN

Open the controller door with the attached key .
To get to the connector board, release the lock screws on the left side of the
controller beneath the main cover and open the panel .
RAIN OFF
RESET
TEST
RUN TIME
MANUAL
PROGRAM
WEEKLY
CYCLIC
START
VALVES
DURATION
VALVES
DURATION
START
FERTILIZE
SENSOR
WATER
BUDGET
PROGRA
A-B-C
INDEPENDENT
I
WEEKLY
CYCLIC
5
ATTENTION !
It is recommended to position the controller
in an accessible place and at eye-level
- controller door & key
- lock screws
- panel
Installation and Wiring Instructions
EN

MODULE4MODULE6
MODULE5
MODULE3
6
Installation and Wiring Instructions
1. Controller Installation
Install the controller on the wall or in a controller cabinet by mounting it with three screws
at the designated holes . Use the included plugs to cover these screws.
Place a 9V battery in the appropriate place .
EN

7
Installation and Wiring Instructions
2. Adding or Replacing 4 Valve Module
Attention: Modules may be added or replaced only in the A -800248 Model
In order to add or replace a 4 valve module the following procedures must be performed:
1. Turn selector to Testing mode.
2. Disconnect the AC-24V wire.
3. Wait one minute.
4. Remo e battery.
5. With a "cross-head" screwdri er, open
screws on front of module.
6. Add or replace module by pushing it in or
pulling it out.
7. Fasten screws at front of module.
8. Replace battery in position.
9. Reconnect the AC-24V wire.
The number of al es the controller will
now
operate will appear on the LCD display.
The current time must be set.
THE PROGRAMS INSTALLED IN THE CONTROLLER WILL BE STORED
WHEN DISCONNECTED FROM ELECTRICITY (20 YEARS MEMORY!)
- module
- screws
- connector
EN

8
Installation and Wiring Instructions
3. Connecting Solenoid Wires
General
Two wires, identical in color and polarity, are connected to each solenoid. One wire (either
one) must connect to the desired valve in module. The second wire must be connected to
point COM in module. The distance between the controller and the valves is usually longer
than the solenoid wires. An e tension cable may be used.
Extension wire information
· The e tension cable transmits only 24 volt.
· The cable must have at least two wires more then the number of required valves, One for
Master valve and one for Common.
· To facilitate wiring it is recommended to use different colored wires.
· Minimum diameter of the cable must be 0.5 mm., if the valves are at a distance of more
then100 meter from the controller, a bigger diameter will be needed. Please consult with
your distributor.
· The cable must be installed properly on the wall with nail clips or underground in a protective
pipe.
· If cable joins are requires, use protective connection bo .
· Connection of the e tension cable to the valves must be in a protective bo . (Not included).
It is recommended to have more connection points in the bo then number of valves.
EN

9
Installation and Wiring Instructions
SNSR
INPUT
4321 M F
V1
V2
com
V3
V4
S G24AC
L
VM
VF
com
VL
com
RELAY
COM
COM
EN
Table des matières
Langues :
Autres manuels Cepex Système d'irrigation
Manuels Système d'irrigation populaires d'autres marques

Hunter
Hunter Institutional Series Manuel utilisateur

Cellfast
Cellfast 52-305 Manuel utilisateur

Tyco Fire Product
Tyco Fire Product Star Galaxy SGQR Manuel utilisateur

Tyco Fire Product
Tyco Fire Product CENTRAL A Manuel utilisateur

Oral Care Technologies
Oral Care Technologies Hydro Floss Manuel utilisateur

Reliable
Reliable F1-300 Manuel utilisateur