Information about the appliance
Logano G201 - Subject to technical modifications. 5
2 Information about the appliance
These instructions contain important information for the
system operator for the safe operation of the boiler.
2.1 Designated use
The Logano G201 solid fuel boiler is a heating boiler for
coal and wood firing (split log firing) in single and multi-
family houses. In order to ensure proper use, please
observe the details on the rating plate and the specifica-
tions to ensure proper use of this appliance.
2.2 Standards, regulations and direc-
tives
2.3 Operating tips
When operating the heating system observe the follow-
ing:
VThe boiler may only be operated by adults who are
familiar with the instructions and boiler operation.
VMake sure that children are not allowed in the vicinity of
the boiler unsupervised when it is in operation.
VDo not use any fluids for lighting or boosting the boiler.
VAshes should be placed in a steel container with a tight
fitting lid, and moved outdoors. Other waste must not
be placed in this container.
VDo not place or store any flammable objects near the
filling or combustion chamber or at a safety distance of
24 to 48 inches around the boiler.
VDo not place any flammable objects on the boiler.
VOnly clean the surface of the boiler with non-flammable
cleaners.
VDo not store any flammable materials in the boiler room
(e.g. petroleum, oil).
VDo not use any flammable liquids for heating.
VWhile the boiler is operating, do not exceed the rated
output of the boiler (overheating).
VOperate the boiler at a maximum temperature of 194 °F
and check it regularly during operation.
VOperate the boiler with a minimum return temperature
of 131 °F. Ensure that this temperature limit is adhered
to with a suitable set-up.
VThe minimum boiler water temperature must be above
131 °F, because with a lower temperature, steam can
condense. This has negative consequences for the
proper operation of the boiler and its life span.
VThe boiler operator must follow the operating instruc-
tions.
VThe boiler operator may only start up the boiler, take the
boiler out of operation, and clean it. All other work must
be performed by an authorized service company.
VThe service technician is obligated to inform the boiler
operator about the operation and the correct, safe
operation of the boiler.
VIn case of danger of explosion, fire, escaping combus-
tible gases or vapors (e.g. vapors that arise when glu-
ing linoleum, PVC, etc.), do not operate the boiler.
VHeed the flammability of building materials
(Æinstallation and maintenance instructions).
2.4 Air supply
Observe all local codes and standards during
operation! DANGER: Risk of fatal injury from lack of
oxygen in the boiler room!
VMake sure there is adequate fresh-air ven-
tilation by providing air vents to the out-
side.
VPoint out to the system operator that
those air vents must remain open.
WARNING: System damage and risk of
injury in case of incorrect start-up!
Lack of adequate air for combustion can lead
to creosote formation.
VMake sure there is adequate fresh-air ven-
tilation by providing air vents to the out-
side.
VPoint out to the system operator that
those air vents must remain open.
WARNING: Risk of system damage due to
aggressive materials in the ventilation!
During combustion, halogenated hydrocar-
bons that contain chlorine or fluorine com-
pounds cause increased corrosion in the
boiler.
VKeep ventilation free of aggressive materi-
als.
The boiler draws in the required combustion
air from the environment. The boiler may only
be set up and operated in rooms that are per-
manently well-ventilated!