3
Small Weather Shield - Installation, Operation & Maintenance Manual Continued
Special Tools Needed:
• 8 mm (5/16 in.) open-end wrench
• 6 mm (1/4 in.) flat-blade screwdriver
• No. 1 Phillips screwdriver
• No. 2 Phillips screwdriver
21 mm and 22 mm open end wrench
(or two adjustable wrenches)
Parts Included:
Table 1: Parts Included in Small Weather Shield Enclosure Kits
Callout Quantity Description
1A 1 Base, enclosure
1B 1 Clear enclosure cover
1C 4 Screw, cover (factory-installed)
5 1 Bearing, seal carrier (factory-installed)
6 1 Seal, lip (factory-installed)
7 1 O-Ring, RoHS (factory-installed)
8 1 Plate, inner (factory-installed)
9 4 Screw, button head Torx, RoHS (factory-installed)
1024Screw, M3 x 0.5 x 8 mm long, Phillips, oval countersink
1124Washer, flat, M4, plain steel, 4.3 mm ID x 9.0 mm OD x 0.8 mm
1221Bracket, Anti-rotation, weather shield
13 1 Bracket, mounting
14 4 Screw, machine, #6-32 x 1/2 in. long, cross-recessed pan head, RoHS
15 4 Nut, #6-32 hex, flanged, serrated tooth, RoHS
16 1 Bracket, valve
17 1 Bearing, plastic, flanged, split, 20 mm ID, RoHS (factory-installed)
18 1 Shaft, valve
19 3 Screw, tapping, hex washer head, type F, RoHS
Figure 2: Parts Included (See Table 1)
20 1 Thermal barrier
23 2 Gland, cable, PG11 to 1/2 in. NPSL
24 1Cap plug, PG11 with O-Ring, RoHS
25 2Nut, hex, single chamfer, PG11
26 1Label (factory-installed)
3021Screw, tapping, hex washer head, type SW, RoHS
3121Shaft, valve, 1 in. diameter
3221Screw, M4 x 0.7 x 60 mm long, Torx.slotted pan head
1. We recommend using a 1/2 in. liquid-tight conduit and 1/2 in. National Pipe Thread (NPT) liquid-tight fittings (purchased
locally) to terminate the control wiring to the weather shield enclosure strain relief conduit fittings.