Copyright © b-plus technologies GmbH ▪Version V 0.2 ▪Date 2023-12-14 ▪Page 7 of 12
Cold start in the BRICK or DATALynx ATX4 system
NOTICE: It is important to follow the order to avoid data loss.
1 Make sure that the system is in shut-down or power-off state.
2 Insert the xSTORAGE from the front.
3 Close the fasteners correctly.
4 Power on the b-plus system.
✓The LED Status flashes green.
5 Wait until the system has fully booted and the POWER LED is green (10 –50 sec).
6 If the LED does not turn green, repeat from step 1: shut-down, insert the xSTORAGE,
power-on and boot correctly.
See the next instructions if there is a problem:
Make sure that you use the xSTORAGE with the correct connector or adapter in a
compatible b-plus system.
See the description of the compatibility and exchangeability in the related manual
(download portal).
b-plus recommends not to insert more than one xSTORAGE at the same time until
the inserted xSTORAGE is fully in operation.
Hot-remove of the xSTORAGE in the BRICK or DATALynx ATX4 system
1 NOTICE: Data loss by incorrect handling
Make sure the xSTORAGE is not in use before you remove it.
2 Press the LOCK/UNLOCK button to unlock.
✓The LED Status flashes.
3 Wait until all LEDs are off. This can take several minutes, especially when you operate
more than one xSTORAGE.