Bosch AMC2-4R4 Manuel utilisateur

Access Modular Controller
AMC2-4R4
en Installation Manual


Table of contents
1Safety Instructions 5
1.1 Important Safety Notes 5
1.2 Safety Precautions 7
1.3 Unpacking 8
2Important Information 9
2.1 Explanation of symbols in this document 9
2.2 Internet 10
3Introduction 11
3.1 Description 11
3.2 Equipment Configuration 13
3.3 Performance Characteristics 15
3.4 System Overview 16
4Installing 19
4.1 Mounting 19
4.2 Unmounting 20
4.3 Opening the Case 21
4.4 Closing the Case 22
4.5 Cabling 23
4.5.1 Conductor data 23
4.6 Grounding and Shielding 25
4.6.1 Grounding for Host Interface 26
4.6.2 Grounding for Extension Interface 27
4.6.3 Grounding for Bus Interfaces 28
4.7 Connecting Power Supply 29
4.8 Ethernet Host Interface 30
4.9 RS-485 Host Interface 31
4.9.1 RS-485 Two Wire Connection 33
4.9.2 RS-485 Four Wire Connection 33
4.10 RS-232 Host Interface 34
4.11 DIL switch selector 35
4.11.1 Host settings 35
4.12 RS-485 for extension modules 37
4.13 RS-485 Interface for Card Readers 38
Access Modular
Controller Table of Contents | en 3
Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |

4.14 Connecting Relay Outputs 41
4.15 Connecting Analog Input Devices 45
4.16 Tamper Protection 48
5Operating 49
5.1 Status Display of the AMC2 49
5.2 Configuring the Ethernet Interface 52
5.3 Resetting the AMC2 53
5.3.1 Resetting the Software 53
5.3.2 Resetting the Device to Factory Default 54
6Technical Data 55
7Appendices 58
7.1 Connecting Diagrams 58
Index 63
4en | Table of Contents Access Modular
Controller
2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH

Safety Instructions
Important Safety Notes
1. Read, follow, and retain instructions - All safety and
operating instructions must be read and followed properly
before putting the unit into operation. Retain instructions
for future reference.
2. Do not ignore warnings - Adhere to all warnings on the unit
and in the operating instructions.
3. Accessories - Use only accessories recommended by the
manufacturer or those sold with the product. Accessories
not recommended by the manufacturer must not be used,
as they may cause hazards.
4. Installation precautions - Do not place this unit on an
unstable stand, tripod, bracket, or mount. The unit may fall,
causing serious injury to persons and damage to the unit.
Mount the unit according to the manufacturer’s
instructions.
5. Service - Do not attempt to service this unit by yourself.
Opening or removing covers may expose you to dangerous
voltages or other hazards. Refer all servicing to qualified
service personnel.
6. Damage which requires service - Disconnect the unit from
the main AC or DC power source and refer servicing to
qualified service personnel under the following conditions:
– If the power supply cord or plug is damaged.
– If liquid has been spilled or an object has fallen into
the unit.
– If the unit has been exposed to water and/or inclement
weather (rain, snow, etc.).
– If the unit does not operate normally when following
the operating instructions. Adjust only those controls
specified in the operating instructions. Improper
1
1.1
Access Modular
Controller Safety Instructions | en 5
Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |

adjustment of other controls may result in damage,
and require extensive work by a qualified technician to
restore the unit to normal operation.
– If the unit has been dropped or the cabinet damaged.
– If the unit exhibits a distinct change in performance
7. Replacement parts - If replacement parts are required, the
service technician must use only replacement parts that are
specified by the manufacturer. Unauthorized replacements
may result in fire, electrical shock or other hazards.
8. Safety check - Upon completion of service or repair work
on the unit, ask the service technician to perform safety
checks to ensure that the unit operates properly
9. Power sources - Operate the unit only from the type of
power source indicated on the label. If unsure of the type
of power supply to use, contact your dealer
– For units intended to operate on battery power, refer
to the operating instructions.
– For units intended to operate with external power
supplies, use only the recommended approved power
supplies corresponding to norm EN/UL 60950.
– For units intended to operate with a limited power
source, this power source must comply with EN/UL
60950. Unsuitable replacements may damage the unit
or cause fire or shock.
– For units intended to operate at 12V DC normal input
voltage is 12V DC. Voltage input must never exceed
15V DC.
10. Lightning - For added protection during electrical storms
external lightning conductors can be installed. This
prevents power surges from damaging the unit.
11. The units should be installed in locations with restricted
access.
6en | Safety Instructions Access Modular
Controller
2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH

Safety Precautions
Read instructions!
Before working with the AMC2 device, read these instructions
carefully. Make sure you have understood all information
described in this document.
!
Warning!
Risk of electric shock
External power supplies must be installed and put into service
by qualified personnel.
Ensure compliance with the relevant regulations.
Ground the controller.
Disconnect both AC and battery power supply before working
on the controller.
!
Warning!
Risk of fire
Installation of the AMC2 device must comply with any local fire,
health, and safety regulations. A secured door that may be part
of an escape route from an area must be installed with:
Install a fail-safe lock (A), so that the door will be released if
power fails. Ideally, use a magnetic lock.
Install a normally-closed break glass or a manual pull (B) in the
lock supply wiring, so that in an emergency the fail-safe lock
can be immediately powered down.
1.2
Access Modular
Controller Safety Instructions | en 7
Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |

!
Warning!
Risk of explosion of Lithium battery
The battery can explode if it is replaced incorrectly.
Replace only with the same type as recommended by the
manufacturer.
Dispose used batteries according to the battery manufacturer’s
instructions.
Notice!
Risk of damage to equipment
Protect the hardware from electrostatic discharge by observing
ESD instructions before unpacking of touching connectors of
electronics.
Always switch off power of the AMC2 device before modifying
the installation.
Do not connect or disconnect plug connectors, data cables, or
screw connectors while power is on.
Unpacking
Check the packaging for visible damage. If anything has been
damaged during transport, please inform the transport agency.
Unpack the unit carefully. This is an electronic device that must
be handled with care to avoid damage. Do not attempt to put
the unit into operation if components are damaged.
If any parts are missing, inform your customer service
representative or a Bosch Security Systems salesperson. The
shipping carton is the safest transport container for the unit.
Store it and the other packaging material for future use. If the
unit has to be sent back, use the original packaging.
1.3
8en | Safety Instructions Access Modular
Controller
2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH

Important Information
Remarks
This hardware is part of a security system. Access should be
limited to authorized persons only.
Some states do not allow the exclusion or limitation of implied
warranties, or limitation of liability for incidental or
consequential damages, hence the above limitation or exclusion
might not apply to you.
Bosch Security Systems retains all rights not expressly granted.
Nothing in this license constitutes a waiver of Bosch’s rights
under the U.S. Copyright laws or any other federal or state law.
If you have any questions concerning this license, please, write
to:
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany.
Explanation of symbols in this document
Throughout this document, warning messages, important notes,
and helpful tips are presented for the reader. These appear as
follows:
Danger!
Cause of Hazard
Indicates a hazardous situation, which, if not avoided, will result
in death or serious injury.
!
Warning!
Cause of Hazard
Indicates a hazardous situation, which, if not avoided, could
result in death or serious injury.
2
2.1
Access Modular
Controller Important Information | en 9
Bosch Sicherheitssysteme GmbH 2013-08 | AMC2-4R4 |

!
Caution!
Cause of Hazard
Indicates a hazardous situation, which, if not avoided, could
result in minor or moderate injury.
Notice!
Cause of Hazard
Important Notes that must be followed to avoid damage to the
equipment or environment, and to ensure successful operation
and programming.
Tips and shortcuts may also be included in such notes.
Internet
If you are interested in further information on this product or
information on other products, please consult our website at
http://www.boschsecurity.com.
2.2
10 en | Important Information Access Modular
Controller
2013-08 | AMC2-4R4 | Bosch Sicherheitssysteme GmbH
Table des matières
Autres manuels Bosch Contrôleurs d'accès IP