Specifications .................................................................................. 4
1.1 Technical Specification
1.2 Product Dimensions
1.3 Accessories Included with the Unit
1.4 How to determine read model names and serial numbers
2. Installation & Operations Guide ................................................. 8
2.1 Location Requirements
2.2 Installation Requirements
2.3 Electrical Requirements
2.4 Installation Checklist
2.5 How to Remove Machine Panel
2.6 Bin Installation
2.7 Bin S/W Installation
2.8 Water supply & Drain Connections
2.9 Wire
2.10 Final Check
2.11 Test Run
3. Operation ........................................................................................ 18
3.1 Button
3.2 Status Light
3.3 7-Segments
3.4 Operation Cycle
3.5 Safety
3.6 Error Codes
4. Maintenance & Cleaning ............................................................. 22
4.1 Maintenance Period
4.2 Interior Cleaning & Sanitizing Procedure
4.2.1 Cleaning Procedure
4.2.2 Sanitizing Procedure
4.2.3 Product Disassembly
4.3 Level sensor Cleaning
4.4 Exterior Cleaning
4.5 Storage Container and Scoop
4.6 Air Filter
4.7 Condenser
4.8 How to Prepare Unit for LongTerm Storage

Freight Claim Procedure(Important)
23
Inspect Immediately
This product has been carefully inspected and packed in accordance with the
carrier’s packing specifications. Responsibility for safe delivery has been
assumed by the carrier. If loss or damage occurs, you as the consignee must file
a claim with the carrier and hold the container for carrier’s inspection.
Visible Loss or Damage
Any external evidence of loss or damage must be fully described and noted on
your freight bill or express receipt and signed by the carrier’s agent.The claim
should be filed on a form available from the carrier.
Concealed Loss or Damage
Concealed loss or damage should be reported to the carrier and vendor within 24
hours af delivery.
After 24 hours the seller is not responsible for any freight damage incurred.
Keep the product as well as all of the original packaging material in a receiving
area for carrier's inspection.
Warning
Connect to potable water supply only.
Adult Supervision is required for safe use either by children under 8 years of age
or the developmentally disabled.
The warranty does not apply to the following.
Repair or replacement of parts required due to misuse, improper care or storage,
negligence, alteration, use of incompatible supplies or lack of specified maintenance.
Regular maintenance items.
Failures caused by improper or erratic voltages, adverse environmental or water
conditions, improper drainage, interruption in electrical or water supply.
Improper or unauthorized repair.
Any ice machine that has been installed and/or maintained inconsistent with the
instructions provided by Blue Air

1. Specifications
1.1 Technical Specification
300A
Condenser
Air Cooling
Rated Voltage
115V/60Hz/1Ph 220-240V/50Hz/1Ph
220V/60Hz/1Ph
Rated Ampere
8A 6A
6A
Compressor
115 V 37 LRA 6.35RLA 198-254V 18.6LRA 4.04RLA 187-254V 23.4LRA 4.46RLA
Pump
115V 0.53FLA 59.9W 220-230V 0.16FLA 35.9W 220-230V 0.2FLA 41.3W
Fan
115V 0.68FLA 75.2W 220-230V 0.16FLA 35.9W 220-230V 0.29FLA 62.2W
Maximum Breaking
Capacity of Fuse Size
15A -
-
Designed Pressure
HI –580 / LO –320 psig HI – 380 / LO – 195psig
HI – 380 / LO – 195psig
Refrigerant
R-410A 400g (14.1OZ) R-404A 450g (15.8OZ)
R-404A 650g (22.9OZ)
Safety Approval
UL N/A
N/A
Sanitation Approval
ETL N/A
N/A
Energy Star
Certified N/A
N/A
CE
N/A Certified
N/A
KC
N/A N/A
Certified
500A
Condenser
Air Cooling
Rated Voltage
115V/60Hz/1Ph 220-240V/50Hz/1Ph
220V/60Hz/1Ph
Rated Ampere
14A 7A
7A
Compressor
115 V 57 LRA 11.4RLA 198-254V 18.6LRA 4.04RLA 198-254V 30.0LRA 4.35 RLA
Pump
115V 0.53FLA 59.9W 220-230V 0.16FLA 35.9W 220-230V 0.2FLA 41.3W
Fan
115V 0.68FLA 75.2W 220-230V 0.33FLA 56.9W 220-230V 0.29FLA 62.2W
Maximum Breaking
Capacity of Fuse Size
25A -
-
Designed Pressure
HI – 580 / LO –320 psig HI – 380 / LO – 195psig
HI – 380 / LO – 195psig
Refrigerant
R-410A 450g (15.8OZ) R-404A 650g (22.9OZ)
R-404A 600g (21.1OZ)
Safety Approval
UL N/A
N/A
Sanitation Approval
ETL N/A
N/A
Energy Star
Certified N/A
N/A
CE
N/A Certified
N/A
KC
N/A N/A
Certified
45
● Electrical & Refrigerant Data

650A
Condenser
Air Cooling
Rated Voltage
208-230V60Hz/1Ph 220-240V/50Hz/1Ph
220V/60Hz/1Ph
Rated Ampere
9A 6A
6A
Compressor
208~230 V 29LRA 6.8 RLA 198 ~ 264 V 24 LRA 5.9RLA 208~230 V 29LRA 5.6 RLA
Pump
115V 0.55FLA 63.5W 230V/50Hz 0.29FLA 61.7W 220V/60Hz 0.28FLA 61.0W
Fan
115V 0.68FLA 75.2W 220-230V 0.33FLA 56.9W 220-230V 0.29FLA 62.2W
Maximum Breaking
Capacity of Fuse Size
15A -
-
Designed Pressure
HI –580 / LO –320 psig HI –580 / LO –320 psig
HI –580 / LO –320 psig
Refrigerant
R-410A 700g (24.6OZ) R-410A 700g (24.6OZ)
R-410A 700g (24.6OZ)
Safety Approval
UL N/A
N/A
Sanitation Approval
ETL N/A
N/A
Energy Star
Certified N/A
N/A
CE
N/A
Certified N/A
KC
N/A N/A
Certified
900A
Condenser
Air Cooling
Rated Voltage
208-230V/60Hz/1Ph 220-240V/50Hz/1Ph
220V/60Hz/1Ph
Rated Ampere
9A 9A
9A
Compressor
208~230V 41LRA 7.6RLA
220V 50LRA 9.4 RLA 208 ~ 230 V 48 LRA 8.8RLA
Pump
115V 0.55FLA 63.5W 230V/50Hz 0.29FLA 61.7W 220V/60Hz 0.28FLA 61.0W
Fan
115V 0.68FLA 75.2W 220-230V 0.33FLA 56.9W 220-230V 0.29FLA 62.2W
Maximum Breaking
Capacity of Fuse Size
15A -
-
Designed Pressure
HI –580 / LO –320 psig HI –580 / LO –320 psig
HI –580 / LO –320 psig
Refrigerant
R-410A 1100g (38.8OZ) R-410A 900g (31.7OZ)
R-410A 1100g (38.8OZ)
Safety Approval
UL N/A
N/A
Sanitation Approval
ETL N/A
N/A
Energy Star
N/A N/A
N/A
CE
N/A
Certified N/A
KC
N/A N/A
Certified
45

No Model Rated Voltage AT 70 °F / WT 50°F
AT 21 °C / WT 10°C
1 300A 115V/60Hz/1Ph 323lbs/day (146 kg/day)
2 300A 220-240V/50Hz/1Ph 303lbs/day (137 kg/day)
3
300A 220V/60Hz/1Ph 337lbs/day (153 kg/day)
4
500A 115V/60Hz/1Ph 517lbs/day (235 kg/day)
5
500A 220-240V/50Hz/1Ph 463lbs/day (210 kg/day)
6
500A 220V/60Hz/1Ph 457lbs/day (208 kg/day)
7
650A 208-230V60Hz/1Ph 625lbs/day (283 kg/day)
8
650A 220-240V/50Hz/1Ph 726lbs/day (329 kg/day)
9
650A 220V/60Hz/1Ph 643lbs/day (292 kg/day)
10
900A 208-230V60Hz/1Ph 890lbs/day (404 kg/day)
11
900A 220-240V/50Hz/1Ph 858lbs/day (389 kg/day)
12
900A 220V/60Hz/1Ph 915lbs/day (415 kg/day)
● Approximate Ice Production
67

1.2 Product Dimensions
● 300A/500A
67
FRONT
TOP
SIDE
REAR

89
● 650A
FRONT
TOP
SIDE
REAR

89
● 900A
FRONT
TOP
SIDE
REAR

10 11
1.3 Accessories Included with the Unit
1.4 How to determine model names and serial numbers
1.4.1 Model names
1.4.2 Serial number
No Name Picture Quantity
1 Bin switch 1
2 M5 Bolt 4
3 Screw M6 2
4 Earth Screw 1
5 User Manual 1
BLMI-900A
daily ice production in pound
a (4 digits) : CIS code for specific model
b (1 digit) : Product group
c (2 digits) : Manufacturing site
(supplier code)
d (1 digit) : Manufacturing year
e (1 digit) : Manufacturing month
f (5 digit) : Serial number (00001 ~ 99999)
BL : Blueair
M : Modular
(U:Undercounter)
I : Crescentice
Air - cooled
a b d e fc
Year 2015 2016 2017 2018 2019 2020
Mark G H J K M N
Month Jan. Feb. Mar. Apr. May. Jun.
Mark 123456
Month Jul. Aug. Sep. Oct. Nov. Dec.
Mark 7 8 9 A B C
Autres manuels pour BLMI-300A
2
Ce manuel convient aux modèles suivants
3
Table des matières
Autres manuels Blueair Machine à glaçons