Error Codes
1-1. “S1”: Defective Temperature (Room) Sensor
- Sensor is disconnected, open or cabinet temperature is below -58°F
1-2. “S1_”: Defective Temperature (Room) Sensor
- Sensor is shorted or cabinet temperature is above 149°F
2-1. “d1”: Defective Defrost Sensor
- Sensor is disconnected, open or cabinet temperature is below -58°F
2-2. “d1_”: Defective Defrost Sensor
- Sensor is shorted or cabinet temperature is above 149°F
3. “Df1”: Fail to Defrost
- Defrost time exceeds 50 minutes.
4. “CF1”: Fail to Cool
- Defrost sensor reads 32°F or above after 30 mins compressor
operation.
5. “EHF” (Freezer Only): Cabinet Temperature is High.
- Cabinet temperature is above 45°F for 8 hours after the compressor
starts up.
6. “EHr” (Refrigerator Only): Cabinet Temperature is High.
- Cabinet temperature is above 45°F for 8 hours after the compressor
starts up.
7. “Edr”: Door is open more than an hour.
8. “UFN”: V-FAN is disconnected. (Top Mount Refrigerator Only.)