Blue Seal G91 Manuel utilisateur

© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
Gas Salamanders
G91
Servi e Manual

© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY
QUALIFIED PERSONS ONLY.
WARNING:
MAKING ALTERATIONS MAY VOID WARRANTIES AND APPROVALS. IMPORTANT:

© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
This manual is designed to take a more in depth look at the G91 Salamanders for the purpose of
making the units more understandable to servi e people.
There are settings explained in this manual that should never require to be adjusted, but for ompleteness
and those spe ial ases where these settings are required to hange, this manual gives a full explanation
as to how, and what effe ts will result.
Section Page Number
1. Specifications..............................................................................................1
. Installation..................................................................................................3
3. Operation....................................................................................................8
3.1 Des ription of Controls
3.2 Operation
3.3 Ra king
3.4 Explanation of Control System
4. Cleaning / Maintenance............................................................................11
5. Trouble-shooting Guide............................................................................1
5.1 Trouble-shooting Table
5.2 Fault Diagnosis
6. Service Procedures...................................................................................15
6.1 A ess
6.2 Repla ement
6.3 Adjustment / Calibration
7. Accessories................................................................................................ 0
8. Exploded Parts Diagrams.......................................................................... 1
8.1 G91 Main Assembly
8.2 G91 Gas Assembly
8.3 G91 Ra king Assembly
9. Service Contacts........................................................................................ 4
Appendix A. Mounting Hole Locations............................................................ 6
Appendix B. Gas Type Conversion................................................................... 7
Contents

© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander

1
1
Specifications
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
Model Numbers Covered in this Specification
G91 Blue Seal Gas Salamander
External Dimensions
Plan
Front
Side

2
1 Specifications
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
Natural Gas LPG
Main burner (Non-UK models) 1.90 mm 1.20 mm
Pilot burner 0.30 mm 0.20 mm
Main burner (UK models) 1.65 mm 1.05 mm
Injector Sizes
Gas Supply (Non-UK models)
Salamander Internal Dimensions
Ra k Size 610mm x 310mm
Branding Plate (a essory) 610mm x 310mm
Cooking Area
G91 41kg
Weight (Net)
Width Depth Height
G91 685 mm 330 mm 230 mm (at front)
Natural Gas LPG
(29,850 BTU) (29,850 BTU)
Supply Pressure 1.13 - 3.40 kPa 2.75 - 3.40 kPa
(4.5” - 13.5 w. .) (11” - 13.5” w. .)
Operating Pressure 1.0 kPa (*) 2.5 kPa (*)
(4.0” w. .) (10.0” w. .)
Gas Conne tion 1/2” BSP Male
Input Rating (N.H.G.C.) 31.5 MJ/hr 31.5 MJ/hr
Regulator Spring Orange Blue
Gas Supply (UK models)
Natural (G20) Propane (G31)
Heat Input (Gross) 8.8 kW 8.8 kW
Gas Rate 0.84 m3/hr 0.63 kg/hr
Supply Pressure 20 mbar 37 mbar
Operating Pressure 15 mbar 37 mbar
Regulator Used Yes No
Gas Conne tion 1/2” BSP Male

Installation
3
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
Installation Requirements
NOTE: It is most important that this salamander is installed correctly and that operation is
correct before use. Installation shall comply with local electrical, gas, health and
safety requirements.
Blue Seal Salamanders are designed to provide years of satisfa tory servi e, and orre t installation is
essential to a hieve the best performan e, effi ien y and trouble-free operation.
This applian e must be installed in a ordan e with National installation odes and in addition, in
a ordan e with relevant National / Lo al odes overing gas and fire safety.
AUSTRALIA: - AS5601 - Gas Installations.
NEW ZEALAND: - NZS5261 - Gas Installation.
UNITED KINGDOM: - Gas Safety (Installation & Use) Regulations 1998.
- BS6173 - Installation of Catering Applian es.
- BS5440 - 1 & 2 Installation Flueing & Ventilation.
IRELAND: - IS 820 - Non - Domesti Gas Installations.
Installations must be carried out by qualified service persons only. Failure to install
equipment to the relevant codes and manufacturer’s specifications shown in this section will
void the warranty.
Components having adjustments protected (e.g. paint sealed) by the manufacturer are only
allowed to be adjusted by an qualified service person. They are not to be adjusted by the
installation person.
Unpacking
• Remove all pa kaging and transit prote tion from the applian e in luding all prote tive plasti
oating from the exterior stainless steel panels.
• Che k equipment and parts for damage. Report any damage immediately to the arrier and
distributor.
• Report any defi ien ies to the distributor who supplied the applian e.
• Che k that the available gas supply is orre t to that shown on the rating plate lo ated on the front
bottom orner of the right hand side panel.
• Che k that the following parts have been supplied with the applian e:
Location
1. Installation must allow for a suffi ient flow of fresh air for the ombustion air supply.
Combustion Air Requirements
Natural Gas 9m³/hr minimum.
LPG / Propane 9m³/hr minimum.
2. Installation must in lude adequate ventilation means, to prevent dangerous build up of ombustion
produ ts.
1 x Salamander Ra k. 1 x Wall Mounting Bra ket, in luding;
1 x Trough Tray. - 2 x 25mm Bla k Plasti Spa ers.
1 x Gas Regulator. - 2 x 3/8” Bolts / Nuts.
1 x Alternate Gas Conversion Kit.

Installation
4
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
3. This applian e must be mounted onto a non- ombustible wall or tailored stand, using the rear wall
bra ket and spa ing s rews provided.
4. Combustible walls must not protrude past the front of the applian e.
5. This applian e must not be mounted on a ombustible surfa e or metal surfa e, as radiated heat will
ause these surfa es to be ome extremely hot.
6. Caution should be taken as intense heat is emitted at the bottom front of the applian e.
7. Components having adjustments prote ted (e.g. paint sealed) by manufa turer are only allowed to
be adjusted by an authorised servi e agent. They are not to be adjusted by the installation person.
8. The unit should be mounted under an extra tion hood in omplian e with all lo al regulations.
In the event that the unit is not mounted under an extraction hood, the installer must ensure
that all regulations are met and that there is an unobstructed minimum distance of 750mm
from the top surface of the unit to the ceiling, which must be of non-combustible material.
NOTE: Do not obstruct or block the appliances flue. Never directly connect a ventilation
system to the appliance flue outlet.
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
This unit must be installed on a non- ombustible wall or tailored stand with the following learan es;
* We re ommend allowing a learan e of 100mm on either side of the applian e to allow a ess to the
side panels for servi ing purposes.
** Using the wall mounting a essories provided with this applian e.
*** Top learan e to eiling is subje t to all lo al regulation requirements.
Combustible Surface Non-Combustible Surface
Left/Right hand side 100 mm 25 mm (*)
Rear 30 mm (**) 30 mm (**)
Top Clearan e to:
- Extra tion Hood 200 mm
750 mm - Ceiling (***)

Installation
5
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
Wall Mounting (to non-combustible wall only)
1. Fix the wall mounting bra ket to the wall with six s rews, in su h a position that the top of the
bra ket is level and at least 945mm (38”) above any surfa e beneath the unit. This will ensure that
the bottom of the Salamander is at least 600mm (24”) above any surfa e.
2. Fit the two bla k plasti spa ers to the top
rear orners of the unit. Leave them
uns rewed by approximately 5mm.
3. Fit the two adjusting s rews / bolts into the
nutserts at the bottom rear orners of the
unit. These should protrude approximately
30mm from the rear of the Salamander.
4. Lift the Salamander onto the wall bra ket,
lining up the bla k plasti spa ers on the
salamander with the mounting not hes in the
bra ket.
5. Lower the Salamander onto the mounting bra ket.
6. Tighten the bla k spa ers se urely and adjust the
levelling s rews/bolts to ensure that the unit is level.
~ 5mm
~30mm
Fig 1
Fig 2
Fig 3
Fig 4

Installation
6
© Moffat Ltd, January 2007
Revision 1/
Blue Seal Evolution Series Gas Salamander
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON.
1. Blue Seal Salamanders do not require an ele tri al onne tion, as they fun tion totally on the gas
supply only.
2. It is essential that the gas supply is orre t for the Salamander to be installed and that adequate
supply pressure and volume are available. The following he ks should therefore be made before
installation:-
a. Gas Type the applian e has been
supplied for, is shown on a
oloured sti kers lo ated above
the gas onne tion and next to the
rating plate. Che k that this is
orre t for the gas supply the
applian e is being installed for.
The gas onversion pro edure is
detailed in this manual.
b. Supply Pressure required for this
applian e is shown in the
“Spe ifi ations” se tion of this
manual. Che k the gas supply to
ensure adequate supply pressure
exists.
. Input Rate of this applian e is stated on the Rating Plate and in the “Spe ifi ations” se tion of
this manual. The input rate should be he ked against the available supply line apa ity.
Particular note should be taken if the salamander is being added to an existing
installation.
NOTE: It is important that adequately sized piping runs di-
rectly to the connection joint on the appliance with as
few tees and elbows as possible to give maximum
supply volume.
3. Fit the gas regulator supplied, into the gas supply
line as lose to the applian e as possible.
The regulator onne tions are 1/2" BSP female.
The onne tion to the applian e is 1/2" BSP male.
(Refer to the the “Spe ifi ations” se tion for the gas
supply lo ation dimensions).
NOTE: A Manual Isolation Valve must be fitted to the individ-
ual appliance supply line.
4. Ensure the regulator has the orre t olour spring fitted for the gas type, as detailed in the
“Spe ifi ations” table. Opposite gas type repla ement spring is part of the gas onversion kit
supplied.
5. Corre tly lo ate the applian e into its final operating position and using a spirit level, adjust the legs
so that the unit is level and at the orre t height.
Spring Adjusting
Nut
Cap Nut
Regulator Spring
Coloured for gas type;
- Orange - Nat Gas
- Blue - LPG
Rating Plate
Fig 5
Fig 6
Autres manuels pour G91
2
Table des matières
Autres manuels Blue Seal Gril

Blue Seal
Blue Seal Evolution G592 Manuel utilisateur

Blue Seal
Blue Seal Evolution G592 Manuel utilisateur

Blue Seal
Blue Seal G91 Manuel utilisateur

Blue Seal
Blue Seal E91 Manuel utilisateur

Blue Seal
Blue Seal E91 Manuel utilisateur

Blue Seal
Blue Seal Evolution G592 Manuel utilisateur

Blue Seal
Blue Seal Evolution Series Manuel utilisateur

Blue Seal
Blue Seal Evolution G594 Manuel

Blue Seal
Blue Seal Evolution G592 Guide de configuration

Blue Seal
Blue Seal Evolution G592 Manuel utilisateur