bioscrypt Veri Series Manuel utilisateur

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 1
Checklist For Unpacking
Veri-Series reader
(V-Smart and V-Station differ
from picture shown)
Wall mounting plate /
Mullion mounting plate
(V-Smart and V-Station differ
from picture shown )
Tools
1/8” security hex
key
Pigtail cable
(not included for V-Station)
Documentation
Veri-Series Setup
Guide
Hardware
(4) #6-32 screws
(4) #6 self-tapping
screws
(4) #4-8 wall
anchors
(14) crimps
(1) plastic Aux port
door
(2) #4-40 screws
Documentation provided with your new fingerprint reader is installed
onto your computer when you install the VeriAdmin software (also
available online at http://www.bioscrypt.com). To view the
documentation you can use Windows Explorer (available from the
Start Menu under Programs) to navigate to C:\Program
Files\Bioscrypt\VeriAdmin\Docs or another location that you
defined during the installation procedure. The documentation is
provided in Adobe® Acrobat® format (PDF). The Adobe Acrobat
reader is available on the CD or on-line at www.adobe.com.

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 2
Other required equipment
PC (optional for V-Station)
One available COM port
(or Ethernet card)
Windows 98, ME, NT4,
2000, or XP
486-compatible
16 MB RAM
30 MB disk space
Power supply
Door controller
Networking cable
RS-232/RS-485 Converter
P/S for converter
CD with VeriAdmin
software and
documentation
User
Documentation
(included on
VeriAdmin CD)

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 3
Introduction
The Veri-Series Setup Guide provides you with general information
on installing your fingerprint reader and using the reader and
associated software. This document is not a substitute for the
more comprehensive documentation provided with your reader
and available on the CD-ROM or installed on your computer with
the VeriAdmin software. Please refer to the Veri-Series Installation
Guide and the Veri-Series Operations Manual for additional
information. If there are any questions about information in this
guide or in the more comprehensive documentation please
contact Bioscrypt Technical Support using the contact
information located in the Warranty and Returns section of this
document.
Please see the Release Announcement document on the CD-
ROM for the latest updates to this and other documentation.

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 4
Learning More About Your New Fingerprint
Reader
Pass/Fail Indicator
Amber – place finger
Off – remove finger
Green – Pass
Red – Fail
Power Indicato
r
Conductive Plastic
RidgeLock™ to aid in
consistent finger
placement
Fingerprint Sensor
ABS Plastic Bod
y
Aux. Port
Internally, your fingerprint reader is powered by hardware and
software developed by Bioscrypt. The “bioscrypt on board™” logo
signifies that Bioscrypt's biometric technology has been integrated
into this product. It provides the assurance that Bioscrypt's high
standards of biometric quality and security reside within the product.

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 5
The V-Smart™ Fingerprint Reader
Pass/Fail Indicator
Amber – place finger
Off – remove finger
Green – Pass
Red – Fail
Conductive Plastic
Fingerprint Sensor
RidgeLock™ to aid in
consistent finger placement
Power Indicato
r
MIFARE®or
iCLASS™ smart
card reader
ABS Plastic Bod
y
Aux. Port

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 6
The V-Station™ Fingerprint Reader
Pass/Fail Indicator
Amber – place finger
Off – remove finger
Green – Pass
Red – Fail
Conductive Plastic
Fingerprint
Sensor
RidgeLock™
Power
Indicator
LCD Backlit
Display
Illuminated
Keypad
Some models:
MIFARE®or
iCLASS™ smart
card reader or
HID Proximity
reade
r
Aux. Port ABS Plastic Body

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 7
The Veri-Series Product Line
The Veri-Series fingerprint readers are used in access control and
other related fields. There are a variety of features common to
the various products, but there are differences as well, as
described below. For more on the operational differences
between the products please see Basic Operation on page 29.
Common Features
The various products in the Veri-Series line have some features
in common such as both RS-232 and RS-485 serial
communications protocol support for connection to a PC,
Wiegand input and output protocol support for connection to
access control equipment, a wide power input range (9-24
Volts DC) except for the V-Smart (9-12 Volts DC) and V-Station
(12.5-24 Volts DC), and a requirement for earth ground
connection to dissipate static electricity (ESD).
Product Specific Differences
V-Prox™: The V-Prox has a built-in HID proximity card reader that
negates the need for external Wiegand input, and provides
one-to-one fingerprint authentication. The V-Prox is capable of
storing up to 4000 fingerprint templates (a “template” is a
mathematical model of the fingerprint that is generated during
enrollment). The device can be mounted on door Mullion or
single-gang electrical box.
V-Flex™: The V-Flex has all the capabilities and features of the
V-Prox described above except that there is no built-in HID
proximity card reader. Therefore the V-Flex requires an
external Wiegand input signal. The V-Flex is designed for

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 8
retrofit applications and for applications where a card
technology other than HID is desired.
V-Pass™: The V-Pass provides one-to-many fingerprint
identification for small user populations (the system is optimized
for user populations up to 100, but can be used for populations
up to 200). The V-Pass provides fingerprint only identification –
no cards or PINs are required to use the system. The V-Pass is
also small enough to be mounted on a door mullion or a
single-gang electrical box.
V-Smart™: The V-Smart supports one-to-one fingerprint
authentication by means of an industry standard MIFARE®-
compatible or iCLASS™ contactless smart card reader. The
fingerprint template is stored on the smart card, not on the
reader, so the user population is unlimited – simply issue a smart
card to each employee.
V-Station™: The newest addition to the Veri-Series product line,
the V-Station contains a backlit LCD display and keypad,
enabling template management and unit configuration
directly from the unit; a PC is not required. Variations of this
product are offered with an HID proximity card reader, a
Smartcard reader (MIFARE or iCLASS), or as a searching unit.
Also, this is the first product to offer Ethernet support. It is
probably the most versatile product in the Veri-Series.
MIFARE® is a registered trademark of Philips Semiconductors
iCLASS™ is a trademark of HID Corporation

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 9
Required Connections
The following table shows required and optional connections
to the various products.
Product Power
Input Wiegand
Input Wiegand
Output Serial
Comm. Earth
Ground
V-Prox *** **
V-Flex *** **
V-Pass ***
V-Smart * ***
V-Station * *** **
*The power input on V-Smart is 9-12 VDC and 12.5-24VDC on V-Station
instead of 9-24 VDC on the other products.
** RS-485 communication is typically used for template distribution to
multiple units.
*** Wiegand output is typically used to send the user information (ID number
and facility code from card) to an access control panel, but this
connection is not strictly required.

Veri-Series Setup Guide
© Copyright 2004 Bioscrypt Inc. All rights reserved. Document #430-00111-17 10
Preparing Wiring
1. Wiring connections to be made:
Wiegand – should be 18-22 AWG (10-7 MWG) wire,
between 3 and 6 conductors depending on which signals
will be carried, shielded cable is recommended, and
typically the conductors are made of stranded wire.
Minimum connections: Data0, Data1, Wiegand Ground
RS-485 – use category 5 shielded cable.
Ethernet – use category 5 shielded cable
Power – should be 18 – 22 AWG (10 – 7 MWG) wire, 2
conductors.
Earth Ground – use a single wire with heaviest gauge
reasonable.
Warning: Do not use Power Ground as a substitute for Earth Ground.
Autres manuels pour Veri Series
1
Table des matières
Autres manuels bioscrypt Contrôleurs d'accès IP