Bindicator Roto-Bin-Dicator Manuel utilisateur

IOM
LAR180212 Rev. E
Roto-Bin-Dicator®
Single & Double Switch Models
Installation & Operation Manual
StockCheck.com

StockCheck.com

Roto-Bin-Dicator®
Single & Double Switch Models
Installation & Operation Manual
CONTENTS
I. HANDLING & STORAGE ...........................................................................................................................1
Inspection and Handling
Disposal and Recycling
Storage
II. GENERAL SAFETY....................................................................................................................................2
Authorized Personnel
Use
Misuse
III. PRODUCT DESCRIPTION.........................................................................................................................3
TechnicalSpecications
Approvals & Ratings
IV. MECHANICAL INSTALLATION..................................................................................................................4
Mounting Location
Mounting Surface Preparation
Mounting on Side of Bin
Mounting on Top of Bin
V. ELECTRICAL INSTALLATION.................................................................................................................... 5
Wiring for 24V/110V/220V AC Units
Wiring for 24VDC Units
VI. MAINTENANCE .........................................................................................................................................6
Preventative Maintenance
Replacement Parts
StockCheck.com

SAFETY SYMBOLS
WARNING:
IDENTIFIES CONDITIONS OR PROCEDURES, WHICH IF NOT
FOLLOWED, COULD RESULT IN SERIOUS INJURY. RISK OF
ELECTRICAL SHOCK.
CAUTION:
IDENTIFIES CONDITIONS OR PROCEDURES, WHICH IF NOT
FOLLOWED, COULD RESULT IN SERIOUS DAMAGE OR FAILURE
OF THE EQUIPMENT.
StockCheck.com

1
www.bindicator.com
LAR180212 Rev. E
I. HANDLING AND STORAGE
SAVE THESE INSTRUCTIONS
INSPECTION AND HANDLING
Do not dispose of the carton or packing materials.
Each package should be inspected upon receipt for damage that may have occurred due to mishandling during
shipping. If the unit is received damaged, notify the carrier or the factory for instructions. Failure to do so may
void your warranty. If you have any problems or questions, consult the manufacturer Customer Support at
800-778-9242.
DISPOSAL AND RECYCLING
This product can be recycled by specialized companies and must not be disposed of in a municipal collection
site. If you do not have the means to dispose of properly, please contact the manufacturer for return and
disposal instructions or options.
STORAGE
If the Roto-Bin-Dicator®is not scheduled for immediate installation following delivery, the following steps should
be observed:
1. Following inspection, repackage the unit into its original packaging.
2. Select a clean dry site, free of vibration, shock and impact hazards.
3. If storage will be extended longer than 30 days, the unit must be stored at temperatures between 32° and
158° F (0° and 70° C) in non-condensing atmosphere with humidity less than 85%.
CAUTION: DO NOT STORE A NON-POWERED UNIT OUTDOORS FOR A PROLONGED PERIOD.
Roto-Bin-Dicator®
Single & Double Switch Models
StockCheck.com

2
www.bindicator.com
LAR180212 Rev. E
II. GENERAL SAFETY
AUTHORIZED PERSONNEL
Allinstructionsdescribedinthedocumentmustbeperformedbyauthorizedandqualiedservicepersonnel
only. Before installing the unit, please read these instructions and familiarize yourself with the requirements and
functions of the device. The required personal protective equipment must always be worn when servicing this
device.
USE
The device is solely intended for use as described in this manual. Reliable operation is ensured only if the
instrumentisusedaccordingtothespecicationsdescribedinthisdocument.Forsafetyandwarrantyreasons,
useofaccessoryequipmentnotrecommendedbythemanufacturerormodicationofthisdeviceisexplicitly
forbidden.Allservicingofthisequipmentmustbeperformedbyqualiedservicepersonnelonly.Thisdevice
should be mounted in locations where it will not be subject to tampering by unauthorized personnel.
MISUSE
Improper use or installation of this device may cause the following:
• Personalinjuryorharm
• Applicationspecichazardssuchasvesseloverll
• Damagetothedeviceorsystem
If any questions or problems arise during installation of this equipment, please contact the manufacturer
Customer Support at 800-778-9242.
WARNING: ONLY CERTAIN MODELS CAN BE USED IN HAZARDOUS LOCATIONS; SEE NAMEPLATE.
THESE MODELS SHALL ONLY BE USED IN APPLICATIONS COVERED BY THE STATED RATINGS OR
NON-HAZARDOUS LOCATIONS.
StockCheck.com

3
www.bindicator.com
LAR180212 Rev. E
III. PRODUCT DESCRIPTION
Operation centers around the low torque, slow speed synchronous motor. The motor either turns the paddle in the
absence of the bulk material, or turns itself to actuate the micro switch when paddle rotation is stopped by the
bulk material. Constant power to the stalled motor keeps the switch actuated until the paddle is again free to turn.
TECHNICAL SPECIFICATIONS
FUNCTIONAL
Operating Power
24/120/240 VAC; 50/60 Hz, 24 VDC
Power Consumption 5 watts
Motor 1 rpm
Fail-Safe Circuitry Low level fail safe
Switch Rating General Purpose: SPDT 20A @ 125/250/480 VAC.
Pilot Duty: 345 VA, 115 VAC; 690 VA, 230 VAC
Operating Temp -40º F to 113º F (-40º C to 45º C)
PHYSICAL
Drive Shaft Assembly Precision machined shaft with two shielded ball bearings
Shaft Seal Teon®/Viton®Lipseal rated 1/2micron @ 30 psi (2.1 kg/cm2) @ 400º F (204º C)
Housing and Cover
Type 4X/IP66 polyester coated aluminum casting
Mounting Plate 8” outside diameter with 11/4” NPT pipe threaded coupling; standard polyester coated mild steel;
optional 304 stainless steel
Conduit Entry 3/4” NPT or M20 x 1.5
Rigid Shaft and
Paddle Metal parts of all designs are 304 stainless steel
Flex Shaft
Available in neoprene, 155º F (68º C) or silicone, 400º F (204º C) coatings
Shipping Weight Aluminum housing 10 lbs (4.5 kg)
Stainless Steel housing 16 lbs (7.3 kg)
Pollution Degree 2
Installation Category II
Altitude 6,562 ft (2000 m)
APPROVALS & RATINGS
UL (US and Canada):
Ordinary Location Type 4X; IP66
Hazardous Location, Type 4X
Explosion Proof
Dust Ignition Proof
ATEX/IEC/IECex: (Pending)
Dust and Gas Categories; IP66
CE
Electromagnetic Compatibility Directive
Low Voltage Directive
StockCheck.com

4
www.bindicator.com
LAR180212 Rev. E
IV. MECHANICAL INSTALLATION
GUIDELINES
The following precautions should be observed when installing and operating a Roto-Bin-Dicator PRO device:
• Theinstallationandwiringofthisproductmustcomplywithallnational,federal,state,municipaland
local codes that apply.
• Handlecarefullytopreventdamage.
• Donotallowmoisturetoentertheelectronicsenclosure.Conduitshouldslopedownwardfromthe
housing.Installdriploops(ordraintting)andsealconduitwithsiliconerubberproduct.
• Forhorizontallymountedunits,theconduitopeningsmustfacedownward.
The unit must be located at the position where level indication is desired. The unit may be mounted through the
top or side wall of the vessel. To ensure reliable operation, observe the following guidelines when choosing the
mounting location.
• DONOTmounttheRoto-Bin-DicatorPROinanareawherethepaddleorshaftcancontactthevessel.
• DONOTmounttheRoto-Bin-DicatorPROwherethepaddleorshaftaredirectlyintheowofmaterial.
Thematerialshouldbeabletoowontoandawayfromthepaddle.Ifnecessary,useabafetoprotect
thepaddleandshaftfromfallingmaterial(ie.avalanche,massowandin-comingowstream).The
bafeshouldbeplaced6to12inchesabovethepaddle,distancedependonpaddlesize.
WARNING: FOR PRODUCTS MARKED AS TYPE 4X, USE TYPE 4X HUB FITTING; FOR IP66 USE IP66
HUB FITTING.
WARNING: IN ORDER TO MAINTAIN SAFE OPERATION IN HAZARDOUS LOCATIONS, THE
INTEGRITY OF THE ALUMINUM CASTING AND THE EPDM SEALS MUST BE MAINTAINED. THE
USER/INSTALLER MUST AVOID INSTALLATIONS WHERE AGGRESSIVE SUBSTANCES MAY BE
PRESENT AND COULD AFFECT THE PERFORMANCE OF THESE MATERIALS. CARE MUST BE
EXCERCISED WHEN REMOVING AND REPLACING THE COVER, SO NO MARRING, SCRATCHING
OR DAMAGE OCCURS TO THE FLANGES.
CAUTION: WHEN MOUNTING UNITS, NEVER ADJUST THE ORIENTATION BY TURNING THE HOUSING.
USE 2-1/4 IN. WRENCH FOR PROCESS FITTING UNITS, OTHERWISE A STRAP WRENCH SHOULD BE
USED TO TIGHTEN INTO PLACE.
WARNING: FOR UNITS INSTALLED IN HAZAROUS LOCATIONS, TO REDUCE THE RISK OF IGNITION OF
HAZARDOUS ATMOSPHERES, CONDUIT RUNS MUST HAVE A SEALING FITTING CONNECTING WITHIN
18 IN. OF THE ENCLOSURE.
WARNING: REMOVE POWER FROM THE UNIT BEFORE INSTALLING, REMOVING, OR MAKING
ADJUSTMENTS.
StockCheck.com

5
www.bindicator.com
LAR180212 Rev. E
Mounting Plate
H-20 gasket
8.0” O.D.
6.0” I.D.
11/4” NDT
installation for use with mounting plates
1. On a 7 in. bolt circle, drill and tap or drill 6 equally spaced holes in the bin wall for 1/4 in. bolts or cap
screws. If not tapped, bolt heads should be tack welded to the bin inner wall.
2. Cut a 5 in. diameter hole to pass the paddle through. Contact factory for non-standard wall thickness
greater than 1/4 in.
MOUTING - SIDE OF BIN
1. Conduit opening must face down.
2. Assemble gasket between the mounting plate and the bin wall.
3. Flat washer, customer supplied, is recommended between mounting plate and fastening hardware.
Mounting Plate & Gasket Diagram
MOUNTING - TOP OF BIN
1. Assemble gasket between the mounting plate and the bin.
2. Flat washer, customer supplied, is recommended between mounting plate and fastening hardware.
NOTE:Allextendedunitsshouldhaveshaftguardand/orexcoupling.
NOTE: Extended units with shaft lengths greater than 12 inches require a shaft guard.
NOTE: It is recommended that the shaft guard be braced to bin will at 6 foot intervals.
installation for use without mounting plates
Preferred mount is through half couplings; a full coupling will allow material to collect around the shaft, which
may cause additional drag on the rotating shaft.
StockCheck.com

6
www.bindicator.com
LAR180212 Rev. E
V. ELECTRICAL INSTALLATION
CAUTION: IF THE UNIT WAS SUPPLIED WITH A GASKET, AVOID FOLDING, CUTTING OR TEARING
THE GASKET. DAMAGING THE GASKET CAN ALLOW MOISTURE TO ENTER THE ENCLOSURE AND
DAMAGER THE UNIT
GENERAL SAFETY
When using electrical equipment, you should always follow basic safety precautions, including the following:
• Unitsinstalledinhazardouslocationsmustobserveallgovernmentregulationsregardingequipmentin
hazardous locations.
• Theinstallationandwiringofthisproductmustcomplywithallnational,federal,state,municipal,and
local codes that apply.
• Properlygroundtheenclosuretoanadequateearthground.
• Donotmodifyanyfactorywiring.Connectionsshouldonlybemadetotheterminalsdescribedinthis
section.
• Allconnectionsmustuseconductorswithaninsulationratingof300Vminimum,ratedfor221ºF
(105º C),aminimumammabilityratingofVW-1,andbeofappropriategaugeforthevoltageandcurrent
required(seespecications).
• Donotallowmoisturetoentertheelectronicsenclosure.Conduitshouldslopedownwardfromthe
housing. Install drip loops and seal conduit with silicone rubber product.
DISCONNECT REQUIREMENTS FOR PERMANENTLY INSTALLED EQUIPMENT
A dedicated disconnecting device (circuit breaker) must be provided for the proper installation of the unit. If
independent circuits are used for power input and outputs, individual disconnects are required. Disconnects
must meet the following requirements:
• Locatedincloseproximitytothedevice
• Easilyaccessibletotheoperator
WARNING: FOR PRODUCTS MARKED AS TYPE 4X, USE TYPE 4X HUB FITTING; FOR IP66 USE IP66
HUB FITTING.
WARNING: FOR UNITS INSTALLED IN HAZAROUS LOCATIONS, TO REDUCE THE RISK OF IGNITION OF
HAZARDOUS ATMOSPHERES, CONDUIT RUNS MUST HAVE A SEALING FITTING CONNECTING WITHIN
18 IN. OF THE ENCLOSURE.
WARNING: REMOVE POWER FROM THE UNIT BEFORE INSTALLING, REMOVING, OR MAKING
ADJUSTMENTS.
CAUTION: TO REDUCE THE RISK OF IGNITION IN HAZARDOUS ATMOSPHERES, DISCONNECT THE
EQUIPMENT FROM SUPPLY CURCIUT BEFORE OPENING. KEEP ASSEMBLY TIGHTLY CLOSE WHEN IN
OPERATION.
StockCheck.com
Table des matières
Autres manuels Bindicator Instrument de mesure

Bindicator
Bindicator Pulse Point II Series Manuel utilisateur

Bindicator
Bindicator MP Series Manuel utilisateur
Bindicator
Bindicator SonoTracker Ultrasonic Liquid Level Manuel utilisateur

Bindicator
Bindicator Pulse Point LP-500ST Manuel utilisateur

Bindicator
Bindicator PRD1000 Manuel utilisateur

Bindicator
Bindicator VRF-2000R Series Manuel utilisateur
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur