4005294 - ID of received sensor
BatOk 110 - Sensor battery lifetime countdown (it starts at 120 and counts down with each internal process)
0.073bar - Uncompensated sensor pressure, bar/psi, gauge/abs set via <Setup Units> (see 2.7.1)
STAT 51h - Sensor operating mode
G1, G2, G3 - Sensor generation
19C - Sensor temperature reading, C/F selected via <Setup Units> (see 2.7.1)
0 - Sensor CRC
ARHML - Sensor mode flags
A –Auto transmit (no LF)
R –Roll switch active (moving)
H –Hardware error
M –Measurement error
L –LF triggered transmission
Pressing and releasing the centre key will cause the Mini Analyser to transmit the configured LF code. The LF settings are configured
via the <LF Setup> page. To enter the <LF Setup> page, hold down the right hand arrow.
The <LF Setup> page is used to configure the LF transmission of the Mini Analyser.
The <LF Setup> page should be set up as shown above. Once this is done, press and hold the left hand arrow key to return to the <RF
Receive> page.
With the <RF Receive> page selected, place the Mini Analyser within 30cm of a TPMS wheel sensor and press and release the centre
button to LF Trigger a wheel sensor and have the data from that wheel sensor displayed on the Mini Analyser’s screen like the one
below.
5250125 - ID of received sensor
BatOk 110 - Sensor battery lifetime countdown (it starts at 120 and counts down with each internal process)
T3= 45.5C - IR Tyre Temperature (single for the IR sensor or PIXEL3 for the 5PX). Rim temperature at point 3
when the 5ChWTS sensor is being used.
AMB=22.1C - Ambient temperature of the IR element. C/F selected via <Setup Units> (see 2.7.1)
5PX - Sensor generation
Pressing the< Up> or < Down> buttons navigate through to other <RF Receive> sub-menus to check other data transmitted from the
triggered sensor.