Beta LaserMike DataPro 500 Manuel

DataPro 500 Operator Guide
Proprietary Statement
Contents
Proprietary Statement................................................................................ 3
European Commission Requirements..................................................... 4
Declaration of Conformity......................................................................... 5
General Safety Information ....................................................................... 6
Intended Use .............................................................................................. 6
Laser Safety Precautions .......................................................................... 6
Labels and Safety Features....................................................................... 7
Introduction................................................................................................ 8
Operation.................................................................................................... 8
Key Switch............................................................................................... 8
Programmable Indicator.......................................................................... 9
Fuses......................................................................................................... 12
Cleaning.................................................................................................... 12
Troubleshooting....................................................................................... 13
General.................................................................................................. 13
Servicing and Returning Your Equipment............................................. 14
Part No. MAN/EN5400-0001 Page 2 of 14 Revision B (Jun 2010)

DataPro 500 Operator Guide
Proprietary Statement
Proprietary Statement
Manufacturer/Distributor
Beta LaserMike, 8001 Technology Blvd., Dayton, OH 45424, USA
About This Manual
This manual contains descriptions, drawings, and specifications for a Beta LaserMike product. Equipment or
products made prior to or subsequent to the publication date of this manual may have parts, features, options, or
configurations that are not covered by this manual. Specifications contained herein are subject to change by Beta
LaserMike without prior notice. Beta LaserMike is not responsible for errors or omissions that may be contained
herein or for incidental or consequential damages in connection with the furnishing or use of this information.
Comments or suggestions for possible improvements to the manual are appreciated. Please email us at
manualfeedback@betalasermike.com.
The information contained in this manual is the property of Beta LaserMike. The information disclosed in this
document is furnished in confidence and upon the condition that individual and corporate intellectual rights, whether
patented or not, will be respected. If this document is supplied on removable media (e.g. CD), an electronic copy
(stored on-site) and one printout is permitted. If this document is supplied in printed form, no part of this document
may be reproduced or scanned without the prior written consent of Beta LaserMike. This document may not be
distributed or circulated to third parties.
Limited Warranty
Beta LaserMike will correct by repair, or at Beta LaserMike‘s option, by replacement, F.O.B Beta LaserMike’s plant,
any defect in workmanship or material in any equipment manufactured by Beta LaserMike which appears under
normal and proper use within twelve months from the date of shipment (eighteen months for OEM’s), provided Beta
LaserMike is given reasonable opportunity to inspect the alleged defective equipment at the place of its use and
under conditions of its use.
EXCLUSIONS: This warranty does not cover products which have been modified, altered, or repaired by any other
party than Beta LaserMike or its authorized agents. Furthermore, any product which has been, or is suspected of
being damaged as a result of negligence, misuse, incorrect handling, servicing, or maintenance; or has been
damaged as a result of excessive current/voltage or temperature; or has had its serial number(s), any other
markings, or parts thereof altered, defaced, or removed will also be excluded from this warranty.
Note:
For information
about servicing
and returning
your equipment,
see the section
at the end of this
manual.
WARRANTY SERVICE AT CUSTOMER SITE: Warranty service performed at the customer’s facility will be free of
charge for parts and labor; however, the customer will be liable for transportation and living expenses of personnel
dispatched to effect such repair. A purchase order or other written confirmation of the acceptance of these charges,
signed by an authorized individual, will be required prior to commencement of repairs. Additional charges may be
assessed the customer if: 1) The equipment is not made available on a timely basis, 2) The equipment is found to
be without fault, and/or 3) It is determined the equipment is not under warranty, whether by expiration of the
warranty or any act which voids the warranty.
OTHER THAN AS SET FORTH HEREIN, BETA LASERMIKE MAKES NO WARRANTIES, EXPRESSED OR
IMPLIED, OF MERCHANTABILITY AS TO THE EQUIPMENT MANUFACTURED BY IT, AND THERE ARE NO
EXPRESSED OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE
THEREOF. Beta LaserMike’s obligation to correct defects in such equipment by repair or replacement in
accordance with the foregoing provisions is in lieu of any other warranties, expressed or implied, and in no event
shall Beta LaserMike be liable for incidental or consequential damages. No service of Beta LaserMike’s equipment
is permitted during the warranty period without the specific written consent of Beta LaserMike.
Part No. MAN/EN5400-0001 Page 3 of 14 Revision B (Jun 2010)

DataPro 500 Operator Guide
European Commission Requirements
European Commission Requirements
This equipment is intended for use in a heavy industrial environment. The equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to other equipment. There is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to other equipment the user is encouraged to try to correct the
interference by one or more of the following measures:
- Re-orientate or relocate the equipment.
- Increase the separation between the pieces of equipment.
- Connect the pieces of equipment on separate mains circuits.
- Ensure that the relevant items of equipment are properly and securely earthed to a common earth point using
adequately sized cable or other means of connection.
Where supplied or specified, shielded interconnection cables must be employed with this equipment to ensure
compliance with the pertinent RF limits. Changes or modifications not expressly approved by the company could
void the user’s authority to operate the equipment.
This product has been rigorously tested to comply with the European EMC (Electromagnetic Compatibility) Directive.
With regard to this, Beta LaserMike recommends that any non-Beta LaserMike peripheral equipment is CE marked
for the Heavy Industrial environment (EN50082-2). Beta LaserMike also recommends that any cables not supplied
by Beta LaserMike, but used for powering Beta LaserMike equipment, be built using good EMC practices (i.e. cables
with braided shield, and connectors with 360°termination of the braid to a metal/metalised shell connector at both
ends). If you have any questions regarding this, contact the Beta LaserMike Service Department.
Part No. MAN/EN5400-0001 Page 4 of 14 Revision B (Jun 2010)

DataPro 500 Operator Guide
Declaration of Conformity
DataPro 500 Operator Guide
Declaration of Conformity
Part No. MAN/EN5400-0001 Page 5 of 14 Revision B (Jun 2010)
Declaration of Conformity
Part No. MAN/EN5400-0001 Page 5 of 14 Revision B (Jun 2010)

DataPro 500 Operator Guide
/ General Safety Information
General Safety Information
•Under NO circumstances should the earth safety connections
be broken – internal damage to sensitive electronic components
may occur and at worst electrocution to personnel may result.
•This equipment must be earthed/grounded.
•Relays and associated wiring are rated for SELV levels i.e. 60
Vdc & 30 vac rms. These levels must not be exceeded.
•Maintenance, repairs and electrical connections should be
performed by a suitably qualified person for the country of
installation.
Intended Use
If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Laser Safety Precautions
The laser beam in the optical sensor is very powerful and can permanently damage
eyes not protected by laser safety glasses. To avoid exposing yourself to hazardous
radiation, you must take these precautions:
•Never look into the laser beam. If you must look at the beam,
view it from an angle and in the direction in which the beam is
travelling.
•The beams emitted from the optical sensor are invisible to the
unaided eye. Return the beam shutter to the closed position
when the system is not in use or during setup.
•Ensure that all direct reflections are blocked.
•Remove all rings, watches, or jewelry from your hands when
working on or near the sensor—can cause hazardous
reflections.
•Never install the instrument at eye level.
•Operate the system only with people who have been instructed
in laser safety.
•Post warning signs and lights that are active when laser is
operating.
Part No. MAN/EN5400-0001 Page 6 of 14 Revision B (Jun 2010)

DataPro 500 Operator Guide
Labels and Safety Features
If your country or state has no regulations governing the safe use of lasers, Beta
LaserMike recommends that you follow the guidelines specified by the American
National Standard for the safe use of lasers (ANSI Z136.1–1986). For a copy of this
document write to:
Laser Institute of America
13501 Ingenuity Drive, Suite 128
Orlando, Florida 32826
1-800-345-2737
Labels and Safety Features
This section acquaints you with the advisory and identification labels on the instrument
and the safety features incorporated into the design of the instrument. The following
figure shows the advisory and identification labels on the DataPro 500.
Part No. MAN/EN5400-0001 Page 7 of 14 Revision B (Jun 2010)

DataPro 500 Operator Guide
Introduction
Introduction
The DataPro 500 works in conjunction with LaserSpeed models 4000/8000/9000
speed and length sensors to measure and display the accumulated length and speed
of a product. The length is computed by counting pulses that are transmitted by the
LaserSpeed. The indicator has a front panel LED that can be configured, along with
the LaserSpeed, to indicate status information.
Operation
Key Switch
The DataPro 500 front panel key switch provides laser power and beam shutter
interlock protection. Neither the LaserSpeed’s laser nor the beam shutter will be
activated unless this key is turned to the “I” position. If using a remote interlock, this
key switch works in conjunction with the shutter interlock pins on the rear panel.
Part No. MAN/EN5400-0001 Page 8 of 14 Revision B (Jun 2010)

DataPro 500 Operator Guide
Operation
Programmable Indicator
You can easily configure the DataPro 500 via the pushbuttons on the front panel
monitor. Depending on the application, the monitor is configured with different settings.
This section describes the general operation of the indicator and how to change
settings.
In general, operators do not configure the indicator and are only concerned with
setpoints, if configured as such, and reset.
Part No. MAN/EN5400-0001 Page 9 of 14 Revision B (Jun 2010)

DataPro 500 Operator Guide
Operation
Key Buttons for Users
Parameter Description Notes
PAR Enter programming mode to
enter setpoints* If the unit has been locked out,
only the setpoints will be
accessible
SEL Toggles between length and
speed**
RST Resets the length display and
clears any setpoints**
*The process engineer should have the programming parameters locked out and allow
access to only the setpoints
**This is the default action but can be reconfigured. Refer to the handbook for a
complete reference
Key Parameters for Users
This section only pertains to situations where the indicator is programmed with
setpoints.
The counter should be configured with a lockout code so that only the setpoints are
accessible when pressing the “PAR” key.
Parameter Description Notes
SP-1 The first length setpoint value Sometimes used to signal a
slowdown of the line prior to a
reel/roll change
SP-2 The second length setpoint
value Sometimes used to signal a
reel/roll change
Once the PAR key is pressed, SP-1 will be displayed. To change which digit to edit,
press the SEL key. Use the RST key to increment the actual digit.
Part No. MAN/EN5400-0001 Page 10 of 14 Revision B (Jun 2010)
Table des matières
Autres manuels Beta LaserMike Instrument de mesure
Manuels Instrument de mesure populaires d'autres marques

Endress+Hauser
Endress+Hauser Proline Promag 50 Caractéristiques techniques

Siemens
Siemens SITRANS F Coriolis FCT030 Manuel de la liste des pièces

KLINGER
KLINGER CMF V Series Manuel utilisateur

EXFO
EXFO FTB-2 Manuel d'exploitation et d'entretien

Keysight
Keysight M8290A Manuel utilisateur

ADTEK
ADTEK MW-5 Manuel utilisateur