BEIER-Electronic SV1-2-10Z Manuel utilisateur

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 1
Instruction Manual
Controller
Typ: SV1-2-10Z
BEIER-Electronic
Winterbacherstr. 52/4, 73614 Schorndorf - Weiler
Telefon 07181/46232, Telefax 07181/45732

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 2
Table of Contents
Table of Contents....................................................................................................... 2
Dangers caused by Electric Power............................................................................. 3
Safety-Technical Indications for the User................................................................... 4
General Description of the Device.............................................................................. 5
Technical Data............................................................................................................ 6
Technical Data............................................................................................................ 7
Technical Data............................................................................................................ 8
Technical Data............................................................................................................ 9
Wiring Diagram......................................................................................................... 10
Wiring Diagram (Min/Max-Mode).............................................................................. 11
Technical Description ............................................................................................... 12
Technical Description ............................................................................................... 13
Technical Description ............................................................................................... 14
Technical Description ............................................................................................... 15
Technical Description ............................................................................................... 16
Technical Description ............................................................................................... 17
Technical Description ............................................................................................... 18
Technical Description ............................................................................................... 19
Technical Description ............................................................................................... 20
Technical Description ............................................................................................... 21
Electrical Equipment................................................................................................. 22

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 3
Dangers caused by Electric Power
Emergency !
In the case of danger caused by electric power,
shut-down the machine immediately by means of
the main switch!
Warning!
Damages on the machine may result therefrom.
Operate the controller only with faultless condition of the electrical
equipment. When damages are recognized: Immediate shut-down of the
controller, switch-off by means of the main switch and have it repaired!
Put controller back to use only, if the faultless condition of the electrical
equipment has been verified by an electrician.
In the case of disturbances in the electrical power supply, the controller must
be switched off immediately!
Only use original fuses with the current intensity specified in the Technical
data sheet!
Connecting cables and leads must be laid so that damages and dangers are
excluded and impossible.
Work on the electrical equipment may only be carried out by electricians or
instructed personnel under the supervision of electricians, according to the
electrical-technical regulations in force.

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 4
Safety-Technical Indications for the User
The following indications are for the purpose of personal safety of the operators, as
well as for the safety of the described products and the connected devices.
Non-observance may result in death, serious injuries of the body or damage to
property!
Warning!
Before opening the device
the mains plug must be disconnected.
•Before setting the device into operation the accordance of the mains voltage of
the controller and the feeding device with the local mains voltage must be verified.
•Set and connect plugs, plug link, slide switch according to technical description!
•The set-up is to be carried out by technically qualified personnel!
•Only inductive loads may be connected to the controller!
•Check the electrical equipment of the controller at least once a week for visible
damages and defaults on the outside!
•Detected defaults as well as changes in the operation behavior must be reported
immediately to the person / dept. in charge. Immediate shut-down and securing of
the controller, if required!
Check the electrical equipment of the controller regularly in accordance with the
respective national regulations.

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 5
General Description of the Device
Power unit
The SV1-2-10Z is a control device for oscillation conveyor drives with electromagnets
and works according to the principle of a frequency converter. This control is setting
standards as regards feeding performances, operating comfort and energy savings.
In spite of its very compact construction design the control device SV1-2-10Z covers
the performance range that is usual with vibration feeding devices. As standard finish
the device is equipped with soft start and soft run-out, which can both be adapted at
any time to the connected oscillation conveyor drive.
By means of the external, potential-free control input 10 - 30V AC or DC, the
SV1-2-10Z can be enabled or disabled.
In applications with frequent switching functions (e.g. level control), the
controller may be not constantly switched via the mains voltage! In this case
the control input must be used, since otherwise the life span of the controller
is limited!
All settings, like e.g. set-point input or frequency input are done by means of menue-
assisted key inputs at the front plate.
A 16-digit LC-Display and a status LED inform at any time about the current state of
the SV1-2-10Z.
The electronic current control prevents a possible overload of the control device and
the conveyor system.
Within the indicated limit values there is no setting required for the mains voltage and
mains frequency.
Power supply
The SV1-2-10Z disposes of a switch-controlled 24V DC power pack. It is used for the
supply the internal time function elements, the connected proximity switches and the
outputs (blast air, control output). The power pack is short circuit-proof and can
supply current of max. 1,5A.
Time function elements
The integrated time function elements have an extensive logic (see page 10+11). A
total of 8 times is available enabling the realisation of different functions. These times
can be set from 0,0 to 25,0 seconds.
The SV1-2-10Z is compatible with control SV1-2-10Z. Furthermore, by means of an
optional Input a 2-Sensor min/max level control is also possible.
By a second, adjustable, set-point value e.g. single counter operations can be dosed
more exactly.

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 6
Technical Data
Mains voltage 110 - 230V AC +/-10%
Mains frequency 50 / 60Hz +/-1%
Output voltage 0 - 220V (at 230V mains voltage)
Output current per feeding
device max. 2,5 / 6,0A internal selectable.
With heat sink max. 10,0A
Output frequency 10,0 - 150,0Hz (resolution 0,1Hz)
Load max. 2200 VA. Only inductive loads are allowed to
be connect!
Device fuse 6,3A melting fuse (5x20mm)
Control fuse 1A melting fuse
Electronic over-current
disabling At approx.. 3,5 / 14,0A
Control input 10 – 30V AC or DC (potential-free)
Insulation Voltage Input/Output 0,5kV
Input for set-point selection 10 – 30V AC or DC (potential-free)
Insulation Voltage Input/Output 0,5kV
Inputs for proxmity switches 4 inputs: 10-30V DC
Outputs 4 pnp-outputs: 24V DC, max. 0,5A
1 relay-output: 230V, max. 5A
Soft start 1,0 – 5,0 seconds
Soft run-out 0,2 – 5,0 seconds
Time function elements 4 time function elements with adjustable turn-
on/turn-off delay (0,0 – 25,0 seconds)
Display 16 digit LCD and status-LED
Ambient temperature 0 – 40°C
Dimensions Aluminum housing 160 x 160 x 90mm
Type of protection IP54

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 7
Technical Data

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 8
Technical Data
K51
140
110
160
160
F1
F2
X51
X1
X21
X11
X0

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 9
Technical Data
X0 Connection for mains voltage
X1 Connection for feeding device
X11 Connection for external control input
X12 Connection for control output
X13 Connection for set-point selection
X14 Connection for malfunction output
X15 Connection for optional input
X21 Connection for proximity switch
X31 Connector for blast air valve 1
X32 Connector for blast air valve 2
X41 Connection for proximity switch
X42 Connection for proximity switch
X50 Connection for inputs, outputs and time function elements
X51 Bridge -/PE, relay contacts K51
Q1 Main switch
H1 Status-LED
H2 LC-Display
S1 Key ‚Menue‘
S2 Key ‚Cursor‘
S3 Key ‚Minus‘
S4 Key ‚Plus‘
S5 Key ‚Enter‘
S11 DIP-switch for miscellaneous settings (page 15)
S12 DIP-switch for miscellaneous settings (page 15)
S13 DIP-switch for miscellaneous settings (page 15)
F1 Melting fuse 6,3A
F2 Melting fuse 6,3A
F3 Melting fuse 1A

GB Controller SV1-2-10Z
GB_SV1-2-10Z.DOC 1003 BEIER-Electronic 10
Wiring Diagram
Table des matières
Autres manuels BEIER-Electronic Contrôleurs

BEIER-Electronic
BEIER-Electronic SFR-1-D Manuel utilisateur

BEIER-Electronic
BEIER-Electronic UFR-1230-D Manuel utilisateur

BEIER-Electronic
BEIER-Electronic SV3-1-8Z Manuel utilisateur

BEIER-Electronic
BEIER-Electronic SFR-1-HL Manuel utilisateur

BEIER-Electronic
BEIER-Electronic UFR-1230 Manuel utilisateur

BEIER-Electronic
BEIER-Electronic SFR-1 Manuel utilisateur