Bedford B800 Series Manuel utilisateur

B800 Series
Frequency Inverter
BEDFORD (QUANZHOU) ELECTRONIC CO., LTD

Category
1. Preface ............................................................................................................ 3
2. Notes for safe operation.................................................................................. 3
3. Inspection checkpoints
3.1 Check procedure..................................................................... ……4
3.2 Model explanation.......................................................................... 4
4. Installation
4.1 Exterior size.................................................................................... 5
4.2 Operating environment................................................................... 3
4.3 Notice ............................................................................................. 4
5. Wiring
5.1 Connection diagram ......................................................................... 8
5.2 Notes for operation........................................................................... 9
6. Keyboard Operation
6.1 LCD and operation key .................................................................... 9
6.2 Utility of operation key .................................................................... 10
7. Test run operation........................................................................................... 10
7.1 Master some relevant functions which may let you acquire
more ideal use effects....................................................................... 10
7.2 Keyboard operation mode................................................................ 11
7.3 Keyboard operation for FOR/REV .................................................. 11
7.4 Terminal control mode ..................................................................... 13
7.5 Parameter resume ex-work value..................................................... 13
7.6 Saving condition after parameter modification................................ 14
8. The symbol explanation on LCD ................................................................... 15
9. Parameter and data sheet
9.1 Parameter list.................................................................................... 15
9.2 Parameter explanation...................................................................... 21
10. Fault diagnosis and corrective actions
10.1 Notes for remedy once fault detects................................................. 28
10.2 Troubleshooting................................................................................ 29
10.3 Notes during operation..................................................................... 30
11. BEDFORD- B800-1-200V series standard specification............................. 31
12. BEDFORD- B800-1-400V series standard specification ............................ 32

1. Preface
Thanks for you choose BEDFORD B800 series high functional
frequency inverter, please read this manual carefully before use.
2. Notes for safe operation
Frequency inverter is a latest product for electric and electronic; To
guard your safety, there are signals both “danger” and “notice” in this
manual to remind you safety precaution notices during movement,
installation, operation and check.
!DANGER Misuse may cause casualty.
! NOTICE Misuse may cause damage to inverter or system.
! DANGER
•Please don’t take down, alter! Otherwise, it may cause electric
shock, fire and injure.
•Don’t open the cover during electrify
•Don’t put or insert wire, stick and filament etc. into inverter to
avoid short circuit or electric shock.
•Please don’t splash water or other liquid onto inverter.
! NOTICE
•Please don’t perform a withstand voltage testing to the components
of inverter.
•Absolutely don’t connect output terminal (U, V, W) with AC main
circuit power supply.
•Components CMOS IC on circuit board are easily affected and
damaged by static electricity, please don’t touch it casually.
•Electromotor and inverter should fit to the matched AC power;
Otherwise, it may cause operate abnormality, even burn.

3. Inspection checkpoints
3.1 Check procedure
a) Make sure inverter is same as you purchase.
b) Make sure inverter is in good condition which don’t get
damaged during transportation; if damaged, please don’t
connect with AC main power.
c) Make sure the S/N on warranty is same as inverter.
Please inform our salesperson ASAP if you find the above problems.
3.2 Model explanation
BEDFORD - B800 – 2 001
Motor power: 001-1HP-0.75KW
Voltage: 2 -200V
4-400V
Series No.
Brand

4. Installation
4.1 Exterior Size
400V 1~2HP 3-5HP 7~10HP
200V 1~2HP 3-5HP 7~10HP
H 165mm 214 255
W 120mm 151 180
D 123mm 160 180

4.2 Operating environment
To ensure proper performance and long operation life, Follow the
recommendations below when choosing a location for installing B800
series frequency inverter, Make sure the B800 series frequency inverter
is protected from the following conditions
. Ambient temperature: hanging type, -10~45℃
Tank closed type, -10~40℃.
. Rain, Moisture (For enclosed wall-mounted type)
. Oil fog, salt spray
. Direct sunlight.(Avoid use outdoors)
.Corrosive gases or liquid
. Dust or metallic particles in the air.
. Physical shock, Vibration
. Magnetic noise (Example: welding machine,power devices etc)
.High humidity
. Radioactive materials
. Combustibles: thinners, solvents, etc.
.If few inverters are mounted into cabinet, Please kindly put them on
ventilated position where the good ventilation is available. Further to
mount the cooling fan inside the cabinet to make the ambient
environment under 45℃
. Sufficient mounting space within below stipulation

4.3 Notice
! Notice
•Please don’t hold the front cover when move, the right way is to
hold the heatsink of inverter so as to avoid falling down which
could injury person or damage inverter itself.
•Please mount inverter onto nonflammable materials like metal and
other else; please don’t mount it nearby nonflammable materials
to avoid fire.
•If few inverters are mounted into a controlling cabinet, cooling fan
must be mounted inside cabinet to ensure temperature of cabinet
inside is lower than 45℃to avoid overheat.
• Please cut offAC main power prior to remove keyboard.

5. Wire
5.1 Connection diagram
Note: 1. three phases 380V use R/L, S/N, T as AC main power input terminal, Single
phase 220V only uses R/L and S/N.
2. Braking resistors of single phase 220V/1hp-2hp & three phase 400V/1hp –
2hp are all inbuilt.
3. B800 Series inverter default as keyboard control (F-12=1), it will work after
AC main power input

5.2 Notes for operation
• Parameter F-01 can be set as Max.30000 rpm/Min. of motor rotary,
please use this parameter with care.
• If user wants to operate the RPM of motor higher (F-09/F-10
parameter) than the rated speed of motor, please confirm the
allowable range both motor and machinery.
• The cooling fan of inverter would automatically start to work once
the temperature reach 40℃, Also, it would stop working when its
temperature is under indoor.
• Please attention other relevant parameter settings once braking
resistor used.
• Please don’t check the signal on PCB when inverter is running.
• Parameters have already been set when ex-work, please don’t adjust
it casually.
6.Keyboard Operation
6.1 LCD and operation Key (B800 Series without potentiometer)
(B800-1 Series with potentiometer)

6.2 Utility for operation key
•When inverter ex-work, standard parameters are set as default.
•Press “Enter” key one second, then enter into check/modify
standard parameter group.
•Press or key to check the parameter group from F-01 to F-14
•Press “Enter” key again, which can read parameter value.
•Press or key, modify parameter value.
•Press “Enter” key again, Back to parameter group.
•If press “Enter” key more one second or standby more20 seconds,
Back to initial status prior to standard parameter group modification
•If want to enter into extended menu access(F-15-F-40),set F-14 to
“10”,and press “Enter” key .
7. Test operation
7.1 Master some relevant functions which may help you acquire more
ideal use effects
•Maximum and minimum output frequency F-01&F-02.
The maximum and minimum speed limitations are set according to
actual individual requirements.
•Accelerate and decelerate parameter F-03&F-04.
If linear acceleration time and linear deceleration time too short on
some occasions, which may cause inverter overcurrent and let inverter
trip, which cause motor stop working.
••Stop mode F-05.
When F-05=0, inverter would diminish motor’s speed according to
linear deceleration time.
If F-02≠0, when inverter start, motor would accelerate from mini
frequency we set (F-02), when inverter stops work, the motor linear
decelerate to ‘0’and then stop work.
Ce manuel convient aux modèles suivants
6
Table des matières
Autres manuels Bedford Entraînement CC
Manuels Entraînement CC populaires d'autres marques

Vincent Associates
Vincent Associates UNIBLITZ ED12DSS Manuel utilisateur

EKSMA OPTICS
EKSMA OPTICS DQ-100-4 Manuel de la liste des pièces

Chamberlain Garog
Chamberlain Garog D Series Manuel utilisateur

Parker
Parker PDS Series Manuel utilisateur

Festo
Festo DGC G Series Guide de configuration

Binks
Binks QS-5012-1-CE Manuel utilisateur