Set Momentary Switching for External Switching Relays
To configure the External Switching Relays to act Momentary ON - which shorts the switching
circuit for 100 miliseconds when the relay is pulse-commanded to be "On" or "Off", and
automatically reverting to open circuit afterwards -, follow this procedure:
power off pedal (battery or external power adapter),
set the Multi Function switch to position "1",
press down and hold the footswitch,
power up the pedal (from battery or external power adapter),
hold the footswitch for 3 more seconds, until the LED's are lit as indicated,
release to footswitch to save this setting
power off pedal.
The External Switching Relays will now act Momentary. With power off, set the Multi Function
switch to the other desired function then close the pedal and start using it.
Very Important! Please note that for switching relays in the state "On" or "Off", the same 100
miliseconds of "momentary closed contact" will occur within the relay, which means you will have to
sync visual indication on the pedal with the desired Channel on the amp. If switching relay's state is
preserved when passing from one pedal state to another, i.e. Relay 1 was commanded "On" when
pedal was in Bypass and must be "On" again when pedal passes to Effect, a new momentary
command CANNOT be logically executed, NOR seen by the amp! This is because for either one of
the "On" or "Off" switching relay state execution, the same "100ms momentary ON" command is
issued in this mode of switching, so, inevitably, the relay logic state in TS8-MS is always alternating
on the next execution. As a consequence, it is up to the amp to acknoledge, interpret and respond to
these external momentary commands. It may be needed to go through a pedal power off before being
able to sync relay's state with amp's channel, for those patterns where relays preserve their "On" or
"Off" state when passing from Bypass to Effect.
Reset to Factory Defaults
If for any reason you would like to revert the pedal to all factory settings, follow this procedure:
power off pedal (battery or external power adapter),
set the Multi Function switch to position "F",
press down and hold the footswitch,
power up the pedal (from battery or external power adapter),
hold the footswitch for at least 3 more seconds, until all LED's are blinking,
release to footswitch to save this setting; power off pedal.
The pedal is now reset to Factory Default settings. With power off, set the Multi Function switch
to the other desired function then close the pedal, power it on again and start using it.