Code Display text Explanation
18 Control unit Cooling The fan runs to cool the inside of the appliance.
19 Reset In Progress The appliance resets.
20 Auto Filling The appliance fills the installation.
21 Halted The appliance has stopped. It must be reset manually.
22 Forced calibration The forced calibration function is active.
23 Factory test The factory test mode is active.
24 Hydronic balancing The hydronic balancing mode is active.
200 Device Mode The service tool interface controls the functions of the appliance.
254 Unknown The actual state of the appliance is undefined.
Tab.6 AM014 - Sub status
Code Display text Explanation
0 Standby The appliance waits for a process or an action.
1 AntiCycling The appliance waits to restart, because there were too many consecutive
heat demands (anti-short cycle).
2 CloseHydraulicValve An external hydraulic valve is opened, when this option is connected to the
appliance. An external option board must be connected to drive the valve.
3 ClosePump The appliance starts the pump.
4 WaitingForStartCond. The appliance waits for the temperature to meet the start conditions.
10 CloseExtGasValve An external gas valve is opened, when this option is connected to the ap
pliance. An external option board must be connected to drive the valve.
11 StartToGlueGasValve The fan runs faster, before the flue gas valve is opened.
12 CloseFlueGasValve The flue gas valve opens.
13 FanToPrePurge The fan runs faster to pre-purge.
14 WaitForReleaseSignal The appliance waits for the release input to close.
15 BurnerOnCommandToSu A burner start command is sent to the safety core.
16 VpsTest Valve proving test is active.
17 PreIgnition Ignition starts before the gas valve opens.
18 Ignition Ignition is active.
19 FlameCheck The flame detection is active after the ignition.
20 Interpurge The fan runs to purge the heat exchanger after a failed ignition.
30 Normal Int.Setpoint The appliance operates to reach the desired value.
31 Limited Int.Setpoint The appliance operates to reach the reduced internal desired value.
32 NormalPowerControl The appliance operates on the desired power level.
33 GradLevel1PowerCtrl The modulation is stopped due to a faster heat exchanger temperature
change than gradient level 1.
34 GradLevel2PowerCtrl The modulation is set to low load due to a faster heat exchanger tempera
ture change than gradient level 2.
35 GradLevel3PowerCtrl The appliance is in blocking mode due to a faster heat exchanger tempera
ture change than gradient level 3.
36 ProtectFlamePwrCtrl The burner power is increased due to a low ionisation signal.
37 StabilizationTime The appliance is in stabilisation time. Temperatures should stabilise and
temperature protections are switched off.
38 ColdStart The appliance runs at start load to prevent cold start noise.
39 ChResume The appliance resumes central heating after a domestic hot water interrup
tion.
40 SuRemoveBurner Burner demand is removed from safety core.
41 FanToPostPurge The fan runs to purge the heat exchanger after the appliance stopped.
42 OpenExtFlueGasValve External gas valve closes.
43 StopFanToFlueGVRpm The fan runs slower, before the flue gas valve is closed.
44 StopFan The fan has stopped.
45 LimitedPwrOnTflueGas The power of the appliance is decreased to lower the flue gas temperature.
46 AutoFillingInstall. The auto refill device fills the installation. The installation was empty.