IV
INTRODUCTION TO PANEL
•
Introduction to indicator lamps
Identification Analysis Remark
~
Dynamic and static indication
The lamp is on when scale is in dynamic
state, otherwise, the lamp is off.
→0←
center indication
The lamp is on when the absolute value
of
weight on the scale is less than ±0.2d,
otherwise the lamp is off.
Net Identification of gorses weight and net
weight
The lamp is on in net weight and off in
gross weight
kg
Weight unit
or indicating current unit
Hold
Weight maintenance
The lamp is on when the weight is locked,
otherwise it is off.
Ac
Voltage indication of battery and power
supply The green lamp is on when the voltage of
the adapter and battery is normal, and the red
lamp is on in undervoltage state.
•
Introduction to operation keys
Operationwithout special specification refers to short press on keys.
Each key takes the following functions according to the mesure settings.
Key symbol Normal weighing state Set state
Weight maintenance key
Short press
→
2.1 = 1, keep/cancel.
2.1 = 2, switch between percentage and weight. 2.1
= 5, switch between quantity and weight.
Long key
→
enter setting menu.
Return to the last menu.
Accumulation key
Short key
→
2.1 = 4, include display weight in accu-
mulation value.
Long key
→
2.1 = 3, select scale to sample target
weight.
2.1
=
4, accumulate weight of scale display.
2.1
= 5, count sampling of scale.
No definition.
Unit conversion key
Short key
→
in weighing state, switch weight unit. The
corresponding unit indication lamp is on.
licker bit is on the left.
Skin removal key
Short key
→
net weight turns to gross weight; induction
lamp of net weight “Net” is off.
licker bit is on the right.
Skin removal key
Short key
→
gross weight turns to net weight. Indication
lamp of net weight “Net” is on. Conduct skin removal
operation for multiple times.
Digit flicker position reduces.