Bauma BM600 Manuel utilisateur

INSTRUCTION
MANUAL
PRODUCT NAME: DIGITAL DOOR LOCK
Product Applied:BM600/ BM610
Vietnamese English

Digital door lock
Model BM600 / BM610
BM600 BM610
DECLARATION: THE PRODUCT FOLLOWS THE STRATEGY OF SUSTAINABLE
DEVELOPMENT. THE COMPANY RESERVES THE RIGHT TO MODIFY AND
IMPROVE THE PRODUCT WITHOUT PRIOR NOTICE.
Version 1.0

INDEX
Lock operation
Read before using
FAQ
Product features---------------------------------------------------------1
Warnings------------------------------------------------------------------3
Capacity of unlock way and master/user code-----------------------3
Factory default settings--------------------------------------------------4
How to access to menu setting----------------------------------------4
Menu table----------------------------------------------------------------5
Explanation for advance setting----------------------------------------6
How to input fingerprint-------------------------------------------------9
Common faults and exclusions---------------------------------------10

Read before using
Product features
Five way solution
Fingerprint (only BM610), password, key card, mechanical key and APP (Accessory is needed).
Master/ User Fingerprint, Master/ User Password and Master/ User Key card identification
3 master passwords, up to 47 user passwords.
3 master key cards, up to 47 user key cards.
Anti-spy coding function
Dismantle alert function
Privacy function (Back-lock function)
Prevent mischief and hacking
The random number can be added before or after the real user password but the maximum
length is 16 digits.
This feature will prevent the real user password from being exposed.
When the exterior trim is dismantled by force, the lock is suspended 60 seconds with alarm.
When the privacy (back-lock) function is activated, the door cannot be opened from outside
with user fingerprint,
password or key card except with master identification and / or mechanical key.
* For more details, please refer to the product introduction of each model
Under single verification, when entering 6 times a wrong identification by password
or key card, or 12 times by finigerprint, the lock is suspended 300 seconds with
warning alarm sound 10 seconds long. After that the lock will activate again. While
the lock is suspended, the lock is able to be unlocked by mechanical key only.
Under double verfication,when entering 6 times a wrong identification by fingerprint,
password
or key card, the lock is suspended 300 seconds with warning alarm sound 10
seconds long.
After that the lock will activate again. While the lock is suspended, the lock is able to
be unlocked by mechanical key only.
Any correct identification opens the door or master enter menu setting successfully
before the alarm activate,
all error times will be cleared to zero.
3 master fingerprints, up to 97 user fingerprints (only BM610).
1

Read before using
Product features
Alarm for battery replacement time
Anti-panic function
Passage function
Double verification function
When passage function is activated, the door can be opened from outside without
any verification.
The lockset can be unlocked from inside with simple action of pressing down the handle.
Even privacy function is activated or battery is dead, people can still escape easily from the
emergency such as fire etc.
When the power of battery is too low, a warning signal will appear on the screen.
Please replace all batteries immediately.
For double security purpose, user should input two verification information to unlock
under this function.
2

Warnings
Capacity of unlock way and master/user code
* Read and understand all instructions before use.
* If damage is caused by failure to follow this instructions, the warranty does not apply.
* Only use the alkaline batteries.
* Do not expose the product and accessories to rain or water.
* Do not expose the product to corrosive substances to avoid damage to the protectivecover.
* Do not scrape the fingerprint sensor with any sharp objects, otherwise it may cause permanent
damage.
* When cleaning the product, please wipe with a soft cloth.
* If there is a low battery alert, please replace all the batteries in time and make sure they are properly
installed.
3
Fingerprint
(only BM610) 3 master, 97 user
3 master, 47 user
F001-F003 F004-F100
P004-F050
C004-C050
P001-P003
C001-C003
N/A N/A
N/A
N/A
N/A
2
3 master, 47 user,
1 temporary user,
1 single password
Temporary user:
P052
Single password:
P053
Password
Card
Mechanical key
Solution Capacity Master Code User Code Tem.User Code
Read before using

Factory default settings
How to access to menu setting
CAUTION
Settings Factory defaults
Master identification Any fingerprint (only BM610), any password and any key card
Opening mode setting Single Verification
Dismantle alert Turned on
Speaker Enabled
Wrong identification entry limit
6 times for password
6 times for key card
12 times for fingerprint
System language
1. Press “ ”
2. Enter master fingerprint (only BM610)/password/key card
1. You can follow menu setting shown in display screen to complete the setting.
2. Default master identification is any fingerprint, any password or any key card, please modify it after
installation.
3. After access into menu setting, input key “5” for rolling up, “8” for rolling down.
“ ” is enter key and “ ” is return/escape key.
*Importance: First step is to set your own master identification after installation of lock.
English
4
Read before using

Menu table
* Please see in explanation for advance setting
5
Lock operation

Explanation for advance setting
Delete single user
Delete all user
Time setting
In order to prevent misoperation, when there is only one master identification left (e.g.
master’s fingerprint), the operation of deleting single user in fingerprint setting will be
failed. It is the same for other type of master identification (such as master’ password or
master’s card). The last master identification is able to be deleted by initializing the lockset.
In order to prevent misoperation, when there is only one type of master identification left
(e.g. one master’s fingerprint), the operation of deleting all users in the fingerprint setting
will be failed. There must be at least one other type of master identification (such as
master’s password or master’s card) to delete all fingerprint users. It is the same to delete
all user in password and card setting.
1. Enter the menu by master’s fingerprint/password/card.
2. Select “Time Setting” in the “System Setting” menu.
3. Input date, time and weekday to set time of system
Weekday can input 1-7 for Monday – Sunday respectively.
6
Lock operation

Explanation for advance setting
Temporary user setting
1. Enter the menu by master’s fingerprint/password/card.
2. Select “Temporary User” in the “System Setting” menu.
3. Select “Add Temp. User” and input password for the temporary user.
4. Return to “Temporary User” menu, and then select “Date Setting” to set the start date and end date
that allow the temporary user to unlock by password.
(Noted: the start date and the end date cannot be set on the same day. e.g. if you want the
temporary user can unlock by password on Feb. 20th only, you should set the start date on Feb.
20th and end date on Feb. 21st. The temporary user will not be able to unlock the door by password
after 00:00 a.m., Feb. 21st.)
5. Return to “Temporary User” menu, and then select “Time Range 1” to set the start time and end
time that allow the temporary user to unlock by password. There are 3 time ranges and at least one
of them should be set for the temporary user’s password to take effect. If you set all of the time
ranges with different time period, the temporary user can unlock by password at all set time
ranges on each day of set date.
The format of the time range is 00:00 to 23:59.
e.g. start time: 00:00
end time: 23:59
6. Return to “Temporary User” menu, and then select “Week Setting”. Follow below instruction to
complete the week setting:
A. Input number “0” or “1”.
B. “0” means invalid date, “1” means valid date
C. Input 7 digits (“0” or “1” to stand for availability from Monday to Sunday. The 1st digit stands for
Monday, the 2nd digit stands for Tuesday and so on.
e.g. If the week setting is “0111110”, which means the temporary user cannot unlock the lockset on
the whole day of Monday and Sunday, but he/she can unlock the lockset at the setting time from
Tuesday to Saturday.
The setup of the temporary user will be done after complete above 6 steps strictly.
7
Lock operation
Autres manuels pour BM600
1
Ce manuel convient aux modèles suivants
1
Table des matières
Langues :
Autres manuels Bauma Serrure de porte