AXIOMTEK NA-806D Manuel

NA-806D
Hardware Installation Guide
For service person only

ii
Disclaimers
The information in this manual has been carefully checked and is believed to be accurate.
AXIOMTEK Co., Ltd. assumes no responsibility for any infringements of patents or other
rights of third parties, which may result from its use.
AXIOMTEK assumes no responsibility for any inaccuracies that may be contained in this
document. AXIOMTEK makes no commitment to update or to keep current the information
contained in this manual.
AXIOMTEK reserves the right to make improvements to this document and/or product at
any time and without notice.
No part of this document may be reproduced, stored in a retrieval system, or transmitted,
in any form or by any means, electronic, mechanical, photocopying, recording, or
otherwise, without the prior written permission ofAXIOMTEK Co., Ltd.
©Copyright 2006 by AXIOMTEK Co., Ltd.
All rights reserved.
Version A Nov. 2006
Printed in Taiwan

iii
Safety Approvals
CE Marking
FCC Class A
FCC Compliance
This equipment has been tested and complies with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. If not installed and used
in accordance with proper instructions, this equipment might generate or radiate radio
frequency energy and cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measurers:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Shielded interface cables must be used in order to comply with emission limits.

iv
Safety Precautions
Before getting started, read the following important cautions.
1. Be sure to ground yourself to prevent static charge when installing the internal
components. Use a grounding wrist strap and place all electronic components in any
static-shielded devices. Most electronic components are sensitive to static electrical
charge.
2. Disconnect the power cords from the NA-806D before making any installation. Be
sure both the system and the external devices are turned OFF. Sudden surge of
power could ruin sensitive components. Make sure the NA-806D is properly
grounded.
3. Do not open the system’s top cover. If opening the cover for maintenance is a must,
only a trained technician is allowed to do so. Integrated circuits on computer boards
are sensitive to static electricity. To avoid damaging chips from electrostatic discharge,
observe the following precautions:
9Before handling a board or integrated circuit, touch an unpainted portion of the
system unit chassis for a few seconds. This will help to discharge any static
electricity on your body.
9When handling boards and components, wear a wrist-grounding strap, available
from most electronic component stores.
Trademarks Acknowledgments
AXIOMTEK is a trademark of AXIOMTEK Co., Ltd.
Other brand names and trademarks are the properties of their respective owners.

v
Table of Contents
Disclaimers...................................................................................ii
FCC Compliance.........................................................................iii
C h a p t e r 1........................................................................................1
1.1 General Description....................................................1
1.2 Standard Features......................................................3
1.3 System Specifications.................................................3
1.3.1 Hardware............................................................3
1.4 Dimensions.................................................................5
1.5 Front Panel Outlets.....................................................6
1.6 Rear Panel Outlets.....................................................8
C h a p t e r 2 .....................................................................................9
2.1 Preinstallation Checklist .............................................9
2.2 Setting up the appliance.............................................9
2.2.1 Removing and Replacing the Top Cover...........9
2.2.2 Installing a memory module (DIMM)..................9
2.2.3 Installing a ATA 66/100/133 hard drive............ 10
2.2.4 Connectors & Jumpers ................................... 10
2.2.5 Installing Display Interface...............................11
2.2.6 Installing Serial Port Interface..........................11
2.2.7 Installing Keyboard and PS/2 Mouse
Connectors....................................................................... 14
2.2.8 Installing USB Connector (Optional)............... 14
2.2.9 Enabling LAN by-pass feature........................ 15
C h a p t e r 3..................................................................................... 16
3.1 BIOS Introduction .................................................... 16
3.2 BIOS Setup.............................................................. 16

vi
3.3 Standard CMOS Setup............................................ 17
3.4 Advanced BIOS Features........................................ 20
3.5 Advanced Chipset Features.................................... 23
3.6 Integrated Peripherals ............................................. 27
3.7 Power Management Setup...................................... 29
3.8 PNP/PCI Configuration............................................ 31
3.9 PC Health Status ..................................................... 33
3.10 Load Optimized Defaults......................................... 34
3.11 Set Supervisor/User Password................................ 35
3.12 Save & Exit Setup.................................................... 37
3.13 Quit Without Saving................................................. 38
A p p e n d i x A............................................................................... 39

NA-806D Hardware Installation Guide
Introduction 1
C h a p t e r 1
Introduction
This chapter contains the general information and the detailed specifications of
the NA-806D Network Appliance server. Chapter 1 includes the following
sections:
General Description Mechanical Dimensions
Features I/O Outlets
System Specifications
1.1 General Description
NA-806D Front View (1U Rack mount type)
The NA-806D server is designed for network software solution providers those
have data secure, voice over IP, video streaming, network bandwidth controller
and another networking appliance requirements across this stable and reliable
multiple LAN device.
It has 1U (rackmount or wall mount or desktop) with FAN less design form
factor. There can be deployed up to four LAN ports combinations for customer

NA-806B / C Hardware Installation Guide
2 Introduction
selection in the maximum for application. It also can support LAN by-pass
features which can isolate the defective segments.
NA-806D has pretty good enclosure management interface to be implemented
in the factory default. It can support P.O.S.T (Power On Self Test) feature
through hyper-terminal by console port.And clear LED indicators is available
for status tracking by customer.
And it has room space for one 2.5” hard drive deployment. Customer can
implement system log and monitoring functions through this hardware
specification. With its innovative mechanical and electrical design, the
NA-806D provides one mini-PCI expansion slot for VPN encryption /
decryption adapter board and another type of Mini-PCI adapter card enabling.
It cans enhancement network security process performance and off loads the
CPU loading.
The NA-806D is an excellent networking application platform for network
secure in the SOHO (Small Office and Home Office) market.
CPU Board Part List
Model Number Compact Flash Mini PCI DC in jack
SBC8A806B(B)-4EI for NA-806D-R4EI V V V
Barebone Part List
Model Number Form Factor Number of LAN
Ports CPU CF Mini-PCI Fanless
NA-806D-R4EI 1U,
Rackmount 4 x 10/100Mbps
Intel 82551ER * V V V
*Intel 479-pin socket for Celeron M / Pentium M FSB400 processor

NA-806D Hardware Installation Guide
Introduction 3
1.2 Standard Features
zUltra Low Voltage Intel® Celeron® M processor, low power
consumption and high computing power
zSupports four Ethernet ports
zSupports LAN bypass and BIOS redirected to COM port features
zCompletely fanless in 1U type of rack mount or wall mount
system design.
zSupports accelerate IPsec and incorporates security engines
through Mini PCI socket
zSupports RS-232, CF and 2 USB ports
zSuitable for network appliances: VPN, Network Bandwidth
Controller, SSL/TLS, Firewall, etc,.
zOptional Gigabit LAN ports support (w/o LAN by-pass feature)
1.3 System Specifications
1.3.1 Hardware
zForm Factor:
1U Rack mount or wall mount type w/FAN less design
zCapacity:
It is from 0 to 250GB and beyond, depending on the 2.5” HDD
capacity.
zPower Supply:
External power adapter 12V, 5A (60W)
zHard Drive:
Spacing for 1x IDE HDD (2.5”)
zFront Connector:
1 x Console port
zFront Panel LED:
LED for HDDs
LED for LAN Link/activity
LED for Power
zRear Connector:

NA-806B / C Hardware Installation Guide
4 Introduction
4 x RJ-45 ports
1 x Console port
1 x VGA port
2 x USB ports
1 x KB/MS connector
1 X DC-in power connector
zProcessor:
Intel 479-pin socket for Celeron M / Pentium M FSB400 processor;
up to 2.1GHz
zBIOS:
Award 4MB Flash BIOS Plug & Play
zMain Memory:
One DDR266 SODIMM memory can be up to 1GB in the maximum
zIDE Interface:
Support two ATA 66/100/133 EIDE channels (44-pins)
zSerial Port:
One DB9 connector, other one is Pin reserved
zEthernet:
Totally has four LAN port connections are available.
Two ports of them support LAN by-pass feature
zExpansion:
One Mini-PCI slot is for security encryption card or specialize
functions expansion
zCompact-FlashTM:
One IDE interface CompactFlashTM socket for embedded use
zDimensions:
44mm (H) x 322mm (W) x 160mm (D)
zOperation environment:
Air temperature: 0° C – 40°C (50°F – 113°F)
Humidity: 5% – 95%
zStorage environment:
Air temperature: -20° C – 70°C Humidity: 5% – 95%
Table des matières
Autres manuels AXIOMTEK Serveur

AXIOMTEK
AXIOMTEK NA580 series Manuel utilisateur

AXIOMTEK
AXIOMTEK NA362 Manuel utilisateur

AXIOMTEK
AXIOMTEK NA590 Series Manuel utilisateur

AXIOMTEK
AXIOMTEK NA570 Series Manuel utilisateur

AXIOMTEK
AXIOMTEK NA-814 Manuel

AXIOMTEK
AXIOMTEK NA-0043A Manuel

AXIOMTEK
AXIOMTEK NA-100 Instructions de montage

AXIOMTEK
AXIOMTEK AX62140TP-P4 Manuel utilisateur

AXIOMTEK
AXIOMTEK IRU131 Manuel utilisateur

AXIOMTEK
AXIOMTEK NA-550 Series Manuel utilisateur