AVIRE MRL DCP Manuel utilisateur

MRL DCP
Installation Guide
Ref No MU-875X0AV10A-GB Version 1
AC-2CD00-100-F-20-000
PRODUCT DESCRIPTION
The Machine-Room-Less (MRL) DCP is installed inside the landing controller panel and provides an
information gateway between all compatible connected devices in the elevator shaft and our online
monitoring platform the Avire Hub.
The MRL DCP has an in-built network signal strength scanner to measure the level of signal in its intended
installation location.
Use the MRL DCP as a two-way data link to:
- congure and monitor devices via MK CANBus using the Avire Hub
- remotely test elevators by connecting Lift HAWK
- monitor Panachrome+ light curtains
- update display layouts
- connect EN81-28:2018 compliant emergency communication
ITEMS REQUIRED FOR INSTALLATION
In the Box - MRL DCP
+ MRL DCP
+ P-3.5 H-2V connector (x1)
+ P-3.5 H-3V connector (x1)
+ P-3.5 H-4V connector (x1)
+ P-3.5 H-5V connector (x1)
+ Manual
In the Box - Battery Backup
+ Battery Backup
+ P-3.5 H-3V connector (x1)
+ P-5 BL2 connector (x1)
+ Wiring
Not Included
+ Screwdriver
+ DIN rail (check Lift Controller
for location to x MRL DCP &
Battery Backup)

ELEVATOR SAFETY
Note: All Health & Safety protocols must be followed and all necessary precautions
must be taken before installation.
SETTING UP THE MRL DCP
Avire SIM cards come activated and ready to be installed.
If a non-Avire SIM card is used please activate this before installation, checking with
the SIM provider on how to do this.
1. Insert the SIM card into connector J4 pressing it until it clicks.
2. Connect the antenna on the MRL DCP to J2
and make sure it is completely screwed in.
NOTE: Only use antennas authorised by Avire.
1
*Please refer to pages 11 and 12 for the full picture and connector information
J4*
J2*
You can check the status of the power supply, battery, connection, coverage or
Subscriber Line Interface Circuit (SLIC) at any time by referring to the LED Indicators
(page 13)
3. Connect the power supply (between 10V DC to 30V DC) to J1 using
the 3-pin connector supplied with the unit or connect the device
to the Battery Backup (supplied separately, please refer to page
14 for set up).
4. Verify that the RUN LED ( ) ashes green (this will take a
maximum of 60 seconds). If the SIM LED ( )ashes red, make
sure the SIM is inserted correctly and the SIM PIN is unlocked on
non-Avire SIMs (please refer to page 3, “SIM card unlocking”).
J1*

+Once nished return SW1 dipswitch 1 back to OFF.
7. If a non-Avire SIM card is used, APN settings must be set prior to conguring it
on the Avire Hub (please refer to “Setting Parameters on non-Avire SIM cards” on
page 3). If the SIM LED is red, please refer to “SIM Card unlocking” on page 3.
8. Once the device is set-up and connected, please add it to the Avire Hub online
platform for elevator and device monitoring options (http://hub.avire-global.com/).
Please use the “Help” section for tutorials on how to use the Avire Hub.
2
6. If required, connect additional products to the CANBus via J7 (pin1= Gnd, pin2= CAN L,
pin3= CAN H, pin4= Vcc)
*Please refer to pages 11 and 12 for the full picture and connector information
J7*
5. Check the signal strength by using the built-in network
signal strength scanner. To use this function:
+Turn SW1 dipswitch 1 to ON (check dipswitch 4 is also ON)
+LEDs on the front of the DCP unit will show the network
signal level SW1*

SIM CARD UNLOCKING
Important Note: An Avire SIM card doesn’t have a SIM PIN code, so if the SIM LED is
ashing red please make sure it has been inserted correctly. The SIM PIN code for
other network providers may vary; if there is one it is usually found on the outer
plastic case of the SIM card.
If the SIM LED is ashing red, you may need to add the SIM PIN code to the DCP or
delete it. In this case, follow either of these steps:
3
SETTING PARAMETERS ON NON AVIRE SIMS
OPTION 1
Super settings allow quick and easy conguration of APN settings, depending on the
country and network provider. Using the tables below and on page 4 as an example,
if the country of installation is UK (4), the network provider is EE (3) and the type of
connection is Avire Hub (1), the following text will be sent:
Pin1234, P091 431.
Where Pin1234 is the DCP PIN code, P091 is the command to congure super settings
and 431 is the code for the chosen settings.
The DCP’s default settings are set to 000.
Digit 1 Digit 2 Digit 3
Country Network Type of connection
Digit 1 0-6 7 8
Continent Europe Americas Australasia
OPTION 1 (RECOMMENDED)
You can program the PIN code of the SIM card into the DCP using an analogue phone
plugged into to the J5 connection (please see page 12 for more details).
Enter DCP conguration mode and wait for the DCP response:
Enter SIM card PIN parameter:
is the PIN code given by the service provider.
At this point, the SIM card LED (middle LED) will stop ashing red. If it does not, make
sure the SIM is correctly inserted and you have entered the correct PIN.
OPTION 2
Disable the blocking PIN code using a conventional mobile phone. Plug the SIM into a
dierent mobile device and delete SIM PIN code in the device settings.

Digit 2 1 2 3 4 5 6
Spain Portugal Italy UK Germany France
0default default default default default default
1AvireSim AvireSim AvireSim AvireSim AvireSim AvireSim
2Telefonica MEO Wind O2 Telekom DE Orange
3Orange NOS TIM EE ABD SFR
4Vodafone Vodafone Vodafone Vodafone Vodafone DE Bouygues Telecom
5Iliad 3 O2 DE Free Mobile
6tre(3) Virgin BASE
71P Swisscom
8Telit Telit Telit BT A1 Telit
9GiGa tmobileAT
Digit 3 0 1 2 3
Type Transparent Gateway Avire Hub P100 P100 + Avire Hub
4
Once all digits are selected, the text
needs to be sent to the SIM card
telephone number along with the PIN
code and command:
OPTION 2
If non-Avire SIMs are used and their settings are not covered in the table, APN settings
need to be set up manually:
P060 (P zero six zero) APN address
P061 (P zero six one) APN username
P062 (P zero six two) APN password
P063 (P zero six three) Type of connection
These parameters must be congured by sending an SMS to the SIM card number.
Examples for various regional providers are shown below:
Carrier P060 P061 P062
Vodafone UK wap.vodafone.co.uk wap wap
O2 Germany surfo2 (blank) (blank)
Orange France Orange.fr orange orange
P063 0 1 2 3
Type Transparent Gateway Avire Hub P100 P100 + Avire Hub
Other APN settings are available on the web and can be easily found through any
search engine.

Example of an SMS (for example if the SIM card is from Vodafone):
Pin1234, P060 wap.vodafone.co.uk, P061 wap, P062 wap, P063 1
Important Note: The default PIN code for DCP is always 1234.
If either P061 and P062 is (blank) with no username and password provided (O2
Germany example) and the DCP is congured to be used with the Avire Hub, then the
text message will be:
Pin1234, P060 surfo2, P063 1
If everything is congured correctly you will receive a text within a few minutes. The
example below shows the set-up of parameters for EE UK.
OBTAINING THE CCID NUMBER
AVIRE SIM CARDS
Avire SIM cards come precongured to be used with our products
immediately after plugging them in. You will need to know the CCID
number to add this information to the Avire Hub.
The CCID Number is shown on the back of the SIM card and on the outer plastic case
of the SIM card (highlighted in red on the picture below).
5
Important Note: A CCID number consists of 19 digits.

NON-AVIRE SIM CARDS
It is also possible to retrieve the CCID number by sending a SMS command to a SIM
card telephone number; separating the command by a comma as shown below:
Pin1234, P005?
You will receive a text back within a few minutes with the CCID number; in this example
the number shown after “P005=” is the CCID number of this SIM card.
6

AVIRE HUB
Please contact your local sales oce for access to the Avire Hub.
The link to the Avire Hub is https://avirehub.avire-global.com
Please use the “Help” section of the Avire Hub for up-to-date installation tutorials.
Enter information relevant to your installation in General data
7
Click on “Installations” in the menu and
then on “Buildings”. in “Buildings” click on
“Create Building”.

8
On the other side of the page please enter the number of elevator group(s) you have in
this installation and how many elevators you have in the group. As an example, if this is
a simplex installation the number of elevator groups will be “1” and the number of
elevators will be “1”. If it is a duplex installation, it will be “1” and “2”, respectively.
You can also add group names to know which installation is which; once all
information has been entered click “Next”.
In the new page, you should be able to see Groups and Elevators; click on “Add
Gateway” under “Gateway” tab and select “DCP”.
A pop-up window will appear where you can enter the SIM information (Note: Avire
SIMs are (+31), but this doesn’t aect costs).
Enter all required information and then click “Apply”.
Note: The Background Call Period is the frequency of test checks and 72hrs is the
maximum period as per guidance from standards.

Once you’re in, please click on the “Read Parameters” button. On the right-hand side
of the page you will see a window with time, date and the word “Connecting” written
in green. Once the DCP is connected to the Avire Hub parameters will appear, meaning
your DCP is ready to be connected to emergency phones and other products within
our Ecosystem.
9
Click “Save” in the left corner under the General data column.
To make sure everything has been set up correctly click on the green DCP button
again. You should see the new buttons “Access” and “Events” appear.
Click on the “Access” button.
Table des matières
Langues :