Avigilon AC-ACMEC-KIT16 Manuel utilisateur

Installation Guide
Avigilon™ 16-Door ACM™ Embedded Controller Kit
AC-ACMEC-KIT16

©2015,Avigilon Corporation. Portions © 2003 - 2014 HID Global Corporation. All rights reserved. AVIGILON, the
AVIGILON logo, ACCESS CONTROL MANAGER and ACM are trademarks of Avigilon Corporation. HID, VertX,
V100, V200 and V300 are registered trademarks of HIDGlobal Corporation. Other product names mentioned
herein may be the trademarks of their respective owners. The absence of the symbols ™ and ® in proximity to
each trademark in this product or its packaging is not a disclaimer of ownership of the related
trademark.20151022
Unless stated explicitly and in writing, no license is granted with respect to any copyright, industrial design,
trademark, patent or other intellectual property rights of Avigilon Corporation or its licensors.
This document has been compiled and published covering the latest product descriptions and specifications.
The contents of this document and the specifications of the products discussed herein are subject to change
without notice. Neither Avigilon Corporation nor any of its affiliated companies guarantees the completeness or
accuracy of the information contained in this document and is not responsible for your use of, or reliance on, the
information. Avigilon Corporation shall not be responsible for any damages (including consequential damages)
caused by reliance on the information presented herein.
Avigilon Corporation
http://www.avigilon.com
220-0457B
Revision: 1 - EN
20151022
2

Regulatory
Prior to installation, it is necessary to find a suitable site indoors (this product should always be installed indoors).
It is assumed that the installer has required certifications and required permits. The Installer must follow electrical
standards and AHJ requirements.
All National and local Electrical codes apply.
lThis equipment is intended to be powered from a limited power source output of a previously certified
power supply.
lChanges or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
Class A Digital Devices
FCC Compliance Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Canada Class A
CE Mark – Europe (EU)
C-Tick – Australia and New Zealand
VCCI – Japan
NCC — Taiwan
SRRC— China
IDA — Singapore
KCC — Korea
UL Recognized Component (UL294 and UL1076)
RoHS compliant
3

Table of Contents
Introduction 5
Package Contents 5
Installation 6
Mounting the Control Panel Case 7
Power Supply Board Overview 9
Setup the FPO250 Power Supply Board 10
Setup the FPO75 Power Supply Board 12
Setup the D8P Power Supply Boards 13
Setup the C8 Power Supply Boards 14
Install the ACM Embedded Controller and V100 Subpanels 16
Configure and Wire Data 18
Configure and Wire Power 21
Power On 25
Accessing ACM Embedded Controller Application for the First Time 26
By Virtual Port 26
By Host Name 26
Checklists 27
Tools Checklist 27
Equipment Checklist 27
4

Introduction
The Access Control Manager (ACM) Embedded Controller from Avigilon is an all-in-one security management
application and controller.
The ACM Embedded Controller is a controller embedded with the ACM Embedded Controller application to
provide a flexible and scalable platform for an economic and high performance access control system.
The controller uses a standard TCP/IP network to connect to a browser interface which links to the ACM
Embedded Controller application. The application allows you to effectively control access at each entry point.
Package Contents
The package contents for the 16-Door ACM Embedded Controller are:
lOne AC-LSP-16DR-HID-LCK LifeSafety Power eight door HID dual voltage integrated power system
(shipped in a separate box)
lOne Avigilon AC-HID-ACMEC V1000 ACM Embedded Controller
lEight AC-HID-VERTX-V100 reader interface modules
l16 AC-HID-READ-ICLASS-SE-R10-AVG card readers
l100 AC-HID-CARD-ICLASS-SE-3000-AVG contactless smart card, 2k bit with two application areas
5Introduction

Installation
Before you install the ACM Embedded Controller, read through this entire document.
Refer to the checklist at the end of this document and gather the required information before proceeding with
these instructions.
CAUTION — The controllers and interface panels are sensitive to Electrostatic Discharges (ESD). Observe
precautions while handling the circuit board assembly by using proper grounding straps and handling
precautions at all times.
Installation 6

Mounting the Control Panel Case
Follow the steps below to mount the control panel case.
1. At the installation site, remove the control panel case from the LifeSafety Power FlexPower box.
2. Find two studs in the wall where the enclosure should be installed.
NOTE: In a finished setup, the enclosure and contents together weighs 22.2kg (49lb).
3. Mount the plywood board onto the wall at the desired location.
NOTE: It is highly recommended that the plywood board is mounted to two studs. If no studs are
available, use appropriate drywall anchors that can support the enclosure.
4. Remove one of the two high voltage knockouts.
5. Attach an appropriate cable gland to the 7/8” diameter high voltage opening.
6. Mount the enclosure to plywood using six wood screws.
High voltage knockouts
Low voltage knockouts
Screwholes
7Mounting the Control Panel Case

7. Setup the high voltage junction box (or equivalent), as required. Attach an appropriate cable gland to the
junction box and feed the five AC wires through (two white, two black, one ground).
2
3
1
KEY: 1 is a sample high voltage junction box, while 2 and 3 are sample cable glands.
CAUTION — Do not connect to the main power supply yet.
8. Remove knockout(s) for low voltage input/output wires, as necessary.
9. Attach an appropriate cable gland to each 1 3/8” diameter low voltage opening.
Mounting the Control Panel Case 8

Power Supply Board Overview
Shown below is an overview of the power supply board.
FPO250
D8P
D8P
C8
C8
FPO75
9Power Supply Board Overview

Setup the FPO250 Power Supply Board
Follow the steps below to setup the FPO250 power supply board:
1. Either:
lFor 120V input, leave JP1 intact.
lFor 230V input, cut JP1.
CAUTION:Failure to cut this jumper when using the FPO with a 230VAC input will result in damage
to the system and will void the warranty.
2. Ensure DC output switch is set to 24V (as shown below).
Setup the FPO250 Power Supply Board 10