Aura Cebilon Platinum Manuel

REVERSE OSMOSIS SYSTEM
Cebilon Platinum with pump
Operating and maintenance instructions
Before installing and using the system, please read these instructions carefully.
EN

a
1
We thank you for choosing our reverse osmosis system.
Our Cebilon Platinum reverse osmosis system is available in 2 versions.
· Cebilon Platinum reverse osmosis system
· Cebilon Platinum reverse osmosis system with pump
We recommend that you have the installation carried out by qualied personnel.
Tap water
Water without solid particles
Water without solid particles and chlorine
Clean water
Waste water
2
Water leakage system
1
Regulator
3
Low pressure switch*
4 5 -μm sediment lter
5 Pressure pump*
6 Activated carbon granulate lter
7 1-μm sediment lter
8
4-way shut -o valve
9
Membrane
10
Downstream activated carbon lter
11 High pressure switch*
12 Flow rate restrictor
13
Clean water tank valve
14
Clean water tank
15 Tap
16 Pressure pump adapter (24 VDC)*
* Available for the model with
pressure pump
Fig. 2: Diagram of the reverse osmosis system
THE SYSTEM COMPONENTS
15
11
12
10
9
16
8
5
13
14 7 6
2
1
3
4
Mains water inlet
(Tap water)
Waste water

2
D
ischarge outlet
Outer layer
Waste water
I
nlet
Clean water
Tube
Welded area
The 5-μm sediment lter removes the materials and particles oating in
the water. The activated carbon granulate lter (GAC) lters out organic
materials and unwanted odors. The 1-μm sediment lter removes the rest
of the particles to ensure the correct functioning of the membrane.
The membrane is where the phenomenon of reverse osmosis occurs.
This component consists of a partially permeable material which is wound
in a spiral around the clean water (permeate) collecting pipe. Water that
cannot penetrate the partially permeable membrane is discharged
through the waste water pipe.
Fig. 3: Membrane structure
COMPONENT FUNCTIONS

3
APPLICATION
In order to generate a suitable outlet pressure for the clean water and to
store it under ideal disinfection conditions, the clean water tank has an
inner surface which is covered with a plastic material suitable for
foodstus. With the clean water tank valve you can open and close the
water inlet to the clean water tank.
The downstream activated carbon filter enriches the clean water by
adding minerals. Thereby, the lter regulates pH value of the water before
its consumption.
The flow rate restrictor generates the pressure on the membrane required
for the operation of the system. It is located in the waste water tube.
The mineral-enriched clean water with a regulated pH value can be taken
from the tap.
The l ow pressure switch* stops the pressure pump when the water
supply is turned o or the pressure is less than 0.2 bar (3 psi).
The pressure pump* increases the pressure on the water owing through
the 5-µm sediment lter to the value required for reverse osmosis.
The 4-way shut-off valve regulates the water ow. It interrupts the water
ow as soon as the pressure in the clean water tank reaches the inlet
pressure of the membrane.
The high pressure switch* stops the pressure pump as soon as the
pressure in the clean water tank reaches 2.6 bar (38 psi).
The pressure pump adapter* provides the power supply for the
pressure pump. Here the power supply voltage is converted to 24 VDC.
* Available for the model with pressure pump
This system is used to obtain drinking and cooking water from tap water
by subjecting water that has already passed through the municipal waste
water treatment plant to the process of reverse osmosis.
This water must be microbiologically safe with regard to the required
disinfection.

4
Clean water tank capacity 2.2 gallons (approx. 8 liters)
Clean water tank air pressure
0.40 - 0.48 bar (40 - 40 kPa, 6 - 7 psi)
Daily production 34.03 gpd (128.6 l/d)
Inlet of total dissolved solids
(TDS)
Max. 1250 ppm
Waste water rate 85 - 98 %
Pressure pump ow rate*
0.8 - 1.2 l/m
Pump pressure 0.8 - 1.10 bar (551 - 758 kPa,
80 - 110 psi)
Pump power supply* Input: 220 - 240 VAC / 50/60 Hz;
output: 24 VDC / 0.8 (nom.) max.
1.2 A
System dimensions (mm) 270 x 400 x 385
Total weight With pump: 12.5 kg /
without pump: 9.5 kg
* Available for the model with pressure pump
Do not use water for this system that is microbiologically unsafe, that has
not been suciently disinfected before or after operation or that is of
unknown quality.
Cebilon Platinum reverse osmosis system contains components
that need to be replaced regularly in order to eciently lter the dissolved
solids (TDS) from the water. To check the eciency of the system, check
the water in the system regularly.
Therefore, please also replace regularly the components that need to be
replaced. To ensure continuous eciency and performance of the
system, only use components that meet the dened specications for
replacement.
TECHNICAL SPECIFICATIONS

5
INSTALLATION
The rst lter in the system is the 5 µm sediment lter, in which solid
particles are retained. The water then passes through the activated carbon
granulate lter (GAC). This lter retains organic substances and especially
free chlorine. Furthermore, odors are eliminated. The 1-µm sediment lter
is the last lter before the membrane. This also protects the membrane,
which increases its service life.
The water ltered through the three pre-lters then ows through the
membrane, which forms the basis of the water treatment in the reverse
osmosis system. A large number of small particles are retained here,
which are then discharged through the waste water tube.
The water that has been able to penetrate the membrane rst passes
through the downstream activated carbon lter, which has the function of
a pH regulator, and then to the clean water tank.
To ensure reliable functioning and a long service life of the membrane, the
amount of waste water must always be bigger than the amount of clean
water. The treated clean water in the tank increases the water supply. The
storage capacity of your system is 2.2 gallons, which is approximately
8 liters.
The system is very easy to use and the water pipe system can be easily
installed anywhere. The installation should only be carried out by a
qualied technician.
Cebilon Platinum reverse osmosis system contains components that need
to be replaced regularly to eciently lter the dissolved solids (TDS) from
the water.
Free chlorine can negatively aect the polymer structure of the membrane
within the system.
Please read the operating instructions and pay particular attention to the
chapters about installation, operation, maintenance and warranty conditions.
The operating sequence of the system is shown in Figure 4.
OPERATING PRINCIPLE

6
1- Make sure that the installation is protected against possible freezing.
2- Do not intervene in the waste water system.
3- However, if muddy water (clay etc.) comes out of the pipe, close the
water inlet valve of the system.
4- If you wish to use a water supply system other than the local water
supply system, it must be subjected to a drinking water analysis by the
responsible institutions.
5- If the water used is not tap water, make sure that the water is properly
disinfected.
The ters are considered accessories and are not covered by the warranty.
Clean water
Waste water
Fig. 4: Installation of the reverse osmosis system
WARNING!
Tap water
1- Cebilon reverse osmosis system
2- Water inlet valve
3- Water inlet
4- Waste water outlet
5- Clean water outlet
6- Waste water clamp
7- Tap
7
6
2
1
5
4
3
3

7
d
e
b
Close the water inlet valve.
After the remaining water in the tubes has been drained at the appropriate
points, connect the 3-way adapter to the water inlet. Make sure that there
are no leaks.
First, install the 1/4 " ball valve on the adapter by wrapping it with Teon
tape in a position that allows easy opening and closing of the ball valve
(Fig. 5 a).
Then, connect the water supply hose to the ball valve (Fig. 5 b).
Make sure that the ball valve is closed (Fig. 5 c).
Open the water inlet valve and check the installation for possible leaks
(Fig. 5 d).
Place the system in a suitable place under the sink in an upright position.
Fig. 5: Water connection ttings
WATER CONNECTION
d

8
Install the tap with regard to use and aesthetics.
When drilling through the kitchen worktop or sink, before drilling, make sure
that the dimensions are suitable for installing the washers, nuts and joints
under the kitchen worktop or sink (Fig. 6). Otherwise, there is a risk that you
will carry out the drilling incorrectly.
The tube should be carefully installed between the tap and the clean water
outlet of the system.
Water connection fittings
1 Tap tube
2 Upper tap body
3 Tap handle (open/close)
4 Hub cover
5 Tap body
6 Housing sleeve
7 O-ring of the housing sleeve
8 Mounting piece
9 Plastic mounting piece
10 Plastic mounting washer
11 Washer
12 Compression nut
13 Thread bar
14 1/4" hose
Fig. 6: Tap
INSTALLATION OF THE TAP

9
To install the waste water outlet, drill into the 8 mm diameter hole of the
clamp in the same tube (Fig. 7 b). Connect one end of the 3/8-inch tap to
this clamp and the other end to the 3/8-inch outlet.
Fig. 7: Waste water connection
Fig. 8: Water inlet valve
• Insert the plug of the pressure pump adapter into the 24 VDC power
supply input of the system. Then, connect the adapter to the power
supply.*
• Open the tap for the clean water.
• Close the clean water tank valve.
• By opening the 1/4" ball valve, the tap water is supplied to the
system (Fig. 8). The pump starts working.
• When the water ows, close the tap.
• As soon as pump operation has stopped, check each individual
connection for possible leaks and open the clean water tank valve.
• Since the tank is being lled for the rst time, drain the clean water
at least once.
* Available for the model with pressure pump
CHECKS BEFORE THE START -UP
CONNECTION OF THE WASTE WATE
R
OUTLET
Table des matières
Manuels Système d'eau populaires d'autres marques

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuel utilisateur

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuel utilisateur

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuel utilisateur

Microline
Microline T.F.C.-4 Manuel

Eureka Forbes
Eureka Forbes Aquaguard Select Manuel utilisateur

Cetetherm
Cetetherm AquaEfficiency Manuel utilisateur