Atmos MISSION ONE Manuel utilisateur

© ATMOS Co., Ltd. All rights reserved.
V3.1-20200130

1.General 3
1.1. Diving Safety 3
1.2. Button Function 3
1.3. Power On/Off 4
1.4. Charging 4
1.5. APP Pairing 4
1.6. Unpair 4
1.7. Smart Notification 4
1.8. Sync Log 5
1.9. Firmware Update 5
2. Watch Mode 5
2.1. No Fly Time and Surface Interval 5
2.2. Stopwatch 6
2.3. Enter Water Auto-on 6
2.4. Sunrise & Sunset time 6
3. Scuba Mode 6
3.1. Screen Layout and Alarms 6
3.2. NITROX 9
3.3. Dive Planner 10
3.4. Conservatism 10
3.5. Advanced Setting 10
4. Freedive Mode 11
4.1. Display Layout and Alarms 11
4.2. Time Alarm 13
4.3. Depth Alarm 13
4.4. Stopwatch 13
4.5. Advanced Setting 13
5. Gauge Mode 14
5.1. Display Layout and Alarms 14
5.2. Bottom Timer 15
5.3. Advanced Setting 15
6. GPS and E-Compass 16
6.1. Acquire the GPS signal 16
6.2. Mark Entry/Exit GPS Coordinate 16
6.3. Dive Site Guide 16
6.4. Compass Calibration 17
7. Warranty & Maintenance 17
7.1. Screen Guard 17
7.2. Watch Strap 17
7.3. Storage and Maintenance 17
7.4. Warranty 18
7.5. Specification 19
7.6. FCC Statement 22
2

1.General
1.1. Diving Safety
● All dive gears will fall. It is not whether it will
fall but when it will. Firmware may have bug,
too. Do not use the MISSION ONE as your
only source of information. Have a backup
computer and do dive plan before each dive.
● Diving has risk. Only trained divers should use
the MISSION ONE. Do not use the MISSION
ONE in any dive beyond your certification level.
● MISSION ONE is designed for recreational
diving. Do not use it in commercial diving.
● It is assumed that the diver's ascent rate is
10m/min(33ft/min). Ascending significantly faster
than this will impact decompression calculation.
● Please follow the decompression stops advised
by MISSION ONE. Violation will increase the risk
of decompression sickness, which may lead to
serious injury or death.
● Do not throw, collide, press the MISSION ONE.
Do not expose MISSION ONE under the sunlight
or left it in a car under sunlight.
● Do not bring MISSION ONE into hot spring pool
or sauna.
● After dive, rinse the MISSION ONE thoroughly
with fresh water. Do not use high-pressure spray
in case of damaging the button and sensor. If the
equipment is covered with dirt, soak it in fresh
water and do not use any solvent or detergent.
● Please use the Screen Guard included in the
package. It can be purchased from an authorized
dealer when you need to replace it.
1.2. Button Function
3

1.3. Power On/Off
Power on: Hold button D for 3 sec.
Power off: Hold button D for 3 sec on watch mode.
1.4. Charging
Please make sure the charging point are dry and clean.
It takes 2 hours to fully charge the MISSION ONE.
(Power input : DC 5V/2A)
1.5. APP Pairing
Use ATMOS App to sync dive log.
1. Download ATMOS App:
iOS
https://apple.co/31ouXTE
Android
http://bit.ly/2WAfdNL
2. After logging, go to“Your device”, select “Start
Pairing”.
※ Enable bluetooth of the mobile phone.
※ Android may need to authorize the
connection of the device.
3. MISSION ONE: SETTING → CONNECT →
CONNECT APP: ON
4. ATMOS App: Select the device. Enter the 6 Pin
codes shown on MISSION ONE. Connected!
1.6. Unpair
1. MISSION ONE SETTING → CONNECT →
UNPAIR: YES
2. ATMOS App: Select, or swipe left to delete the
paired MISSION ONE.
3. Your mobile phone: Bluetooth → Forget the
device
1.7. Smart Notification
Smart Notification allows MISSION ONE to show
the message and phone call from the paired
smartphone. (iOS 10, Android)
Enable Smart Notification: MISSION ONE:
SETTING -> CONNECT -> NOTIFICATION: On.
※ If select Call only, MISSION ONE only
notify phone call and SMS.
4

1.8. Sync Log
Sync the dive logs in MISSION ONE to ATMOS
App.
●ATMOS App: Press the sync button on the right
side in the page of Your device.
※ Require stable internet signal.
1.9. Firmware Update
ATMOS regularly releases new firmware
including new feature, bug fix and improvement.
Keep the firmware of your MISSION ONE
updated.
※ Require stable internet signal.
※ If failed to update the firmware via app,
please use USB cable to update.
1. Via USB cable (SUGGESTED):
a. Get firmware update tool from
https://www.atmos.app/support/
(Win10 / Mac)
b. Install, then run the firmware update tool.
c. Connect MISSION ONE to th PC with the
charging cable.
d. Press Update firmware button.
e. MISSION ONE will restart once update is
completed.
2. Via ATMOS App (OTA):
a. Select your device in the ATMOS App.
b. The upgrade button will show if there’s a
new version of firmware.
c. Press Upgrade button.
d. MISSION ONE will restart once update is
completed.
※ If failed to update the firmware via app,
please use USB cable to update.
2. Watch Mode
2.1. No Fly Time and Surface Interval
※ Due to residual nitrogen in body after diving.
Please wait until the No fly time disappears before
taking flight.
※ Avoid moving to an area altitude above 300m
(1000ft).
※ Upper-left: No fly time Icon.
Counting down for 24hr from the
moment exit water in last dive.
※ Upper-right: Surface interval (S.I.)
icon. starts from the moment exit water
in last dive.
5

※ Bottom: Default dive mode (Scuba with air mix/
freedive / gauge)
2.2. Stopwatch
Activate: Hold button C for
2 seconds on watch mode.
▶ Start: Press button B.
▶ Mark: press button B. while
running.
▶ Stop: Press button B.
▶ Reset: Press button B.
when stopped.
▶Exit: Hold button C for 2
seconds.
2.3. Enter Water Auto-on
The default dive mode of auto-on is Scuba Mode.
Default dive mode is changeable in SETTING.
!!!Do not rely on auto-on function. It's important to
check all settings of the dive computer prior to
descent in each dive.
2.4. Sunrise & Sunset time
sunrise| sunset
MISSION ONE shows the sunrise/ sunset time in the
watch mode by pressing button C to scroll the button
information after GPS signal is acquired.
※ How to acquire the GPS signal: 6.1. Acquire the
GPS signal
3. Scuba Mode
3.1. Screen Layout and Alarms
Predive
Upper-left: Compass heading
Left: Ascent rate bar
Mid-left: Water temperature.
Upper-right: NDL (No
decompression limit)
Right: Current depth
Bottom-right: MOD -
(Maximum Operation Depth)
Bottom-right: 21% = AIR /
22-40% = NITROX
※Press button B can access
the advanced setting.
6

During the dive
Upper-left: Compass heading
Left: Ascent rate bar Red =
faster than 10m(33ft)/min.
Left: Water temperature
Upper-right: NDL (No
decompression limit)
Mid: Current depth
Bottom: Dive time
※ Press button C: Scroll to
see current time, maximum
depth and average depth.
※ Press button D: Turning
backlight On/Off.
※ Hold button D: Change
backlight brightness level.
Mark Compass
Heading
Hold button B: Enter mark
compass heading function.
Press button B: Mark heading
degree.
Press button B: Return.
Press button C: Unmark.
※ Because of changes in the
surrounding magnetic field,
it is recommended to
calibrate the compass before
each dive.
Fast Ascent
Alarm appears if ascend too
fast for a period of time.
※ It is recommended to
ascend no faster than
10m(33ft)/min.
7

Time Alarm
Notify when exceed the dive
time limit.
Depth Alarm
Notify when exceed the dive
time limit.
Safety Stop
Safety stop appears when
ascend to 6m(20ft) and the
max depth of the dive is over
10m(33ft).
NDL indicator will be replaced
by a 3mins countdown.
Safety Stop Pause
Ascend above 3m or descend
below 7m during a safety stop.
Safety pause will show and the
countdown will be paused.
Safety Stop Clear
Notify when safety stop is
completed.
NDL below 3mins
Notify every minute when NDL
is shorter than 3 mins.
8

Decompression Stop
Needed
Decompression stops are
mandatory stops that
must be followed in order to
minimize the risk of
decompression illness (DCI).
The“6m” indicates the ceiling
of stop depth.
The “3' " indicates how long
the stop is. (in minute)
※ Please stay close to and
do not exceed the ceiling
depth until finish all deco
stops.
Missed Stop
Alarm appears when ascend
above the deco stop ceiling
depth.
MOD
MOD is the maximum
allowable depth of the current
breathing gas as determined
by
PPO2 limits.
※ Immediately ascend when
seeing MOD alarm.
CNS Alarm
Alarm appears when central
nervous system toxicity loading
percentage is greater than
85%.
※ Immediately ascend when
seeing CNS alarm.
Battery Low
Notify when battery power is
below 20%.
3.2. NITROX
Press button B to enter Advanced setting in scuba
mode. Then find the Air/Nitrox (21-40%)
9

and PPO2 (1.2-1.6) setting.
!!! Always check the oxygen percentage,
PPO2 and corresponded MOD before each
dive.
3.3. Dive Planner
Press button B to enter Advanced setting in scuba mode.
Then find the Dive Plan setting.
Dive Plan
Press button B and button C
to change the plan depth to
see the allowable NDL.
3.4. Conservatism
Press button B to enter Advanced setting in scuba
mode. Then find the CONSERVATISM setting.
!!!Do not change conservatism setting until you
understand the effects.
Conservatism
●HIGH (More conservative)
●NORMAL (Default setting)
●LOW (More NDL than the
NORMAL)
●CUSTOM (Adjust GF low and GF
high)
Adjust GF (Gradient Factor) will affect
decompression calculation. For more
detail, please refer Erik Baker's
(Clearing up the Confusion About Deep
Stops)
3.5. Advanced Setting
On scuba mode prior to a dive, press button B
can enter advanced setting.
!!!Do not change any setting until you
understand the effects.
Advanced Setting:
Conservatism
See 3.4. conservatism
Air/Nitrox
See 3.2. Nitrox
Dive Planner
See 3.3. Dive Planner
10
Autres manuels pour MISSION ONE
1
Table des matières
Autres manuels Atmos Instrument de plongée