ATIM TM2D-HP Series Manuel utilisateur

Concerned models:
ACW/LW8-TM2D-HP
ACW/LW8-TM2D-HP-5
ACW/SF8-TM2D-HP
ACW/SF8-TM2D-HP-5
ATIM Cloud Wireless
Digital temperature sensor with contact
probes
TM2D-HP
User Guide

1
ATIM_ACW-TM2D-HP_UG_EN_V1.2
TABLE OF CONTENTS
Document version history........................................................................................................................3
Disclaimer.................................................................................................................................................3
Trademarks and copyright .......................................................................................................................3
Declaration of compliance.......................................................................................................................4
Environmental recommendations ...........................................................................................................4
a. Explosive atmosphere.................................................................................................................................4
b. Environment ...............................................................................................................................................4
c. Radio...........................................................................................................................................................5
Technical specifications ...........................................................................................................................6
Housing ....................................................................................................................................................7
a. Space requirements....................................................................................................................................7
b. Opening the ACW housing..........................................................................................................................8
c. Mounting to a support................................................................................................................................8
d. Identification...............................................................................................................................................9
e. Placement and installation .......................................................................................................................11
Operation...............................................................................................................................................12
a. Periodic mode (shown as ‘Periodical’ in the configuration tool)..............................................................12
b. Energy Saver mode ...................................................................................................................................13
ACW configuration tool..........................................................................................................................14
a. What version of the ACW configuration tool should you use? ................................................................14
b. Configuring the LoRaWAN network pairing mode: ..................................................................................15
c. Configuring the Energy Saver mode .........................................................................................................16
d. Configuring periodic mode .......................................................................................................................17
e. Factory settings.........................................................................................................................................17
Uplink frame formats.............................................................................................................................18
a. Sigfox and LoRaWAN ................................................................................................................................18
b. Example ....................................................................................................................................................18
c. Startup sequence......................................................................................................................................19
Downlink ................................................................................................................................................20
a. Keep-alive frame frequency......................................................................................................................20
b. Mode of operation....................................................................................................................................20
c. Lower threshold........................................................................................................................................20
d. Upper threshold........................................................................................................................................20
e. Temperature sampling period ..................................................................................................................21
f. Temperature offset probe 1 .....................................................................................................................21
g. Pairing with LoRaWAN network ...............................................................................................................21
h. Delta for comfort zone probe 1 ................................................................................................................21

2
ATIM_ACW-TM2D-HP_UG_EN_V1.2
i. Statement period when outside the comfort zone ..................................................................................21
j. Codes reserved for future developments:................................................................................................21
k. Lower threshold probe 2 ..........................................................................................................................22
l. Upper threshold probe 2 ..........................................................................................................................22
m. Temperature offset probe 2 .....................................................................................................................22
n. Delta in confort zone probe 2...................................................................................................................22
Connecting the modem .........................................................................................................................23
Accessing data on the web (Sigfox and LoRa solutions)........................................................................24
a. Viewing probes on the ACW platform ......................................................................................................24
b. Registering the modem on the Sigfox network ........................................................................................25
c. Registering the modem on the LoRaWAN network..................................................................................28
Troubleshooting.....................................................................................................................................29
Technical support...................................................................................................................................29

3
ATIM_ACW-TM2D-HP_UG_EN_V1.2
Document version history
Version
Date
Description
Author
0.1
12/11/2015
Document creation
YL
0.2
25/11/2015
Table of Contents generation
YL
0.3
18/05/2016
Network addition
YL
0.4
02/06/2016
Corrections
YL
0.5
10/06/2016
Corrections
YL
0.6
12/12/2017
Eco-energy and downlink mode addition
CB
0.7
05/03/2018
Visual labels updates (/Cfg ACW/Sigfox)
CB
1.0
26/03/2018
Error codes addition + startup sequences
precision + decoding examples of received frames
CB
1.1
24/10/2019
Upgrade from TM2D to TM2D-HP (batteries
modification + PCB unit visual + USB port)
ER
1.2
09/01/2020
Corrections
MD
Disclaimer
The information contained in this document is subject to change without warning and does not represent a
commitment on the part of ATIM radiocommunications. ATIM radiocommunications provides this document ‘as-is’
with no warranty of any kind, express or implied, including but not limited to implied warranties of merchantability or
fitness for a particular purpose. ATIM radiocommunications may make changes and/or improvements to this manual
or to the product(s) or program(s) described in this manual, at any time.
Trademarks and copyright
ATIM radiocommunications®, ACW ATIM Cloud Wireless® and ARM Advanced Radio Modem® are registered
trademarks of ATIM SARL in France. The other trademarks mentioned in this document are the property of their
respective owners.

4
ATIM_ACW-TM2D-HP_UG_EN_V1.2
Declaration of compliance
All ACW Atim Cloud Wireless® products comply with the regulatory requirements of the R&TTE Directive
(1999/5/EC), article 3:
1 SAFETY (Article 3.1a of the 1999/5/EC Directive)
NF EN60950-1 Ed. 2006/A1:2010/A11:2009/A12:2011 (health)
EN62479: 2010 (power <20mW) or EN62311:2008 (power > 20mW)
2 Electromagnetic compatibility (Article 3.1b of the 1999/5/EC Directive)
EN 301489-3 v1.4.1, EN 301489-1 V1.9.2
3 Efficient use of the radio frequency spectrum (Art.3.2 of the 1999/5/EC Directive)
ETSI EN300 220-2 v2.4.1 and EN300 220-1 v2.4.1
Environmental recommendations
Explosive atmosphere
Except for the ACW-ATEX line specifically intended for this purpose, do not use ACW radio modems in the presence of
flammable gases or fumes. Using the equipment in such an environment constitutes a safety hazard.
Environment
Respect the temperature ranges for storage and operation of all products. Failing to respect these guidelines could
disrupt device operation or damage the equipment. ACW products in IP65 water- and dust-resistant housings may be
placed outdoors but must not be submerged under any circumstances.
Follow the instructions and warnings provided below to ensure your own safety and that of the environment and to
protect your device from any potential damage.

5
ATIM_ACW-TM2D-HP_UG_EN_V1.2
General hazard –Failure to follow the instructions presents a risk of equipment damage.
Electrical hazard –Failure to follow the instructions presents a risk of electrocution and physical injury.
Direct-current symbol
WARNING: do not install this equipment near any source of heat or any source of humidity.
WARNING: for your safety, it is essential that this equipment be switched off and disconnected from mains
power before carrying out any technical operation on it.
WARNING: the safe operation of this product is ensured only when it is operated in accordance with its
intended use. Maintenance may only be performed by qualified personnel.
Waste disposal by users in private households within the European Union. This symbol appears on a product or
its packaging to indicate that the product may not be discarded with another household waste. Rather, it is your
responsibility to dispose of this product by bringing it to a designated collection point for the recycling of electrical
and electronic devices. Collection and recycling waste separately at the time you dispose of it helps to conserve
natural resources and ensure a recycling process that respects human health and the environment. For more
information on the recycling center closest to your home, contact your closest local government office, your local
waste management service or the business from which you purchased the product.
Radio
Modems in the ACW line are radio-communication modems that use the ISM (industrial, scientific and
medical) bands, which may be used freely (at no cost and with no authorization required) for industrial,
scientific and medical applications.

6
ATIM_ACW-TM2D-HP_UG_EN_V1.2
Technical specifications
Dimensions
154 x 54 x 54 mm
Antenna
Integrated (¼ wave)
Temperature probes
Numerical
Cables length
2 or 5 meters
Temperature
-20°C to +55°C (operating mode)
-40°C to +70°C (storage)
-55°C to +125°C (probes)
Mounts to
Wall, tube or pole, DIN rail
Housing
IP 65
Power supply
2 battery-packs (14,4 Ah)
Weight
280 g
Frequency
865 –870 MHz
Power
25 mW (14 dBm)
Rate
Sigfox: 100 bps
LoRaWAN: 300 bit/s à 10 Kbit/s
Consumption
Sigfox *:
LoRaWAN:
Tx mode
60 mA
50 mA
Standby mode
7 µA
7 µA
Rx mode
35 mA
18 mA
* For youe information, the ACW-TM2D-HP modem is qualified in U0 class at Sigfox.
Temperature
Range
-55°C │+125°C
Resolution
0.5°C (9 bits)
Precision between -10°C and +85°C
+/- 0,5°C
Precision between -55°C and -10°C
Precision between +85°C and +125°C
+/- 2°C

7
ATIM_ACW-TM2D-HP_UG_EN_V1.2
Housing
a. Space requirements
Maximum cable diameter through cable gland: 7 mm

8
ATIM_ACW-TM2D-HP_UG_EN_V1.2
b. Opening the ACW housing
The housing must be opened to access both the terminal block and the mini-USB
port used to configure the module.
To do this, insert a screwdriver into the slot and tilt it downward to lift the inside
tab (see photo). Then pull on the back panel to separate the two parts of the
housing.
c. Mounting to a support
ACW modems can be mounted on a flat wall, a tube or pole or a DIN rail, depending on the type of installation you
require.
These three types of support frames attach to the rear of the housing.
Mounting on a flat wall (provided):
Mounting on flat wall (provided):
Installation on a tube:
Mounting on a DIN rail:
Opening slot

9
ATIM_ACW-TM2D-HP_UG_EN_V1.2
d. Identification
The Sigfox or LoRaWAN product identifier is visible on the exterior label on the back of the device, on the electronic
card inside and in the status bar in the ACW configuration tool.
For LoRaWAN modems, the communication keys are automatically provided by the network (pairing via ‘Over The Air
Activation’, or OTAA).
Each ATIM ACW product line has a QR Code label visible either on the side or on the front of the product.
ACW-TM1D-HP product label
ACW/XXX-TM2D-HP
Product ID :
Sigfox or LoRaWAN version
Revision n° of the product
(hardware and firmware
technical status)
Sigfox ID or LoRaWAN
DevEUI
Serial number
Datamatrix :
Sigfox ID
or
LoRaWAN DevEUI
Ce manuel convient aux modèles suivants
4
Table des matières
Autres manuels ATIM Régulateurs de température
Manuels Régulateurs de température populaires d'autres marques

Swegon
Swegon LUNAd MB Manuel utilisateur

Lucky Reptile
Lucky Reptile Thermo Control II Manuel utilisateur

SENSORMETRIX
SENSORMETRIX Argon 100 Manuel utilisateur

Fuji Electric
Fuji Electric PXE4 Manuel utilisateur

Yuyao gongyi
Yuyao gongyi XMT-808 series Manuel utilisateur

Selec
Selec TC544C Manuel utilisateur