ARTECH AR120 DUET Manuel utilisateur

DUET
Operate Instruction
Version1.0.0

DUET Operate Instruction
1
INDEX
1 INTRODUCTION ……………………………………………………………..2
2 APPEARANCE………………………………………… ……………………….3
3 CONTENT ……………………………………………………………………..4
4 SYSTEM REQUIREMENT ….………………………………………………..4
5 INSTALLATION…………………………………………………………………5
6 MAIN MENU …………………….……………………………………………..7
7 SETUP ……………………………….…………………………………………... 8
8 RECORD ……………………………….…………………………………… …14
9 ANSWER MACHINE …………………………...……… ………………….19
10 SERVICE AND WARRANTY …………………………………………….20
11 CONTACT ………………………………………………………………22

DUET Operate Instruction
2
1
2
INTRODUCTION
Thank you for purchasing product.
This device is single line voice logger. It can record all the calls over the phone
including Caller ID, date, time and elapse. You can also enable its answering
machine function; it will record all the messages for you when you are
unavailable.
APPEARANCE

DUET Operate Instruction
3
3
4
1) USB Port
2) DV 5V
3) LINE port
4) PHONE port
5) Play Message
6) Handset Line
7) Volume +
Accessory information
1. AR100
2. Operation Instruction
3. USB Cable
4. DC5V Adaptor
5. 2G SD Memory card
PC Requirement
1. Windows7/Vista/XP/2000
2. Pentium 400 MHz CPU 以上
3. 256 MB RAM
4. 1GB HDD space
5. USB port
8) Volume –
9) Handset
10) SOURCE PHONE
11) SOURCE MICROPHONE
12) SET
13) Microphone
14) DELETE
15) Earphone
16) Fast Forward
17) Recording
18) Fast Reverse
19) Pause
20) Play
21) Stop
22) Page Down
23) Page Up
24) Back
25) Records
26) SD Card
27) LCD Display
28) Answering Machine
29) Speaker

DUET Operate Instruction
4
5
Connection
1.Analog line connection:
a. Switch the SOURCE to PHONE
b. Telecom line to LINE port
c. Phone to PHONE port,
** will be shown on the LCD. See P.9 for set up.

DUET Operate Instruction
5
2.Digital phone Connection (Handset):
a. Switch SOURCE to PHONE
b. Connect handset line to LINE
c. Connect handset to PHONE
** will be shown on the LCD. Voice trigger setup is necessary. See
Page 9 for set up.
3.Microphone connection (Environmental Record):
a. Switch SOURCE to MICAR120
** will be shown on LCD. See Page 8 for set up.
Remark:See Page 11 for initial Time/Date set up.

DUET Operate Instruction
6
6 Main Menu
(A)Standby mode
:Remaining Battery capacity
:Recording display (錄音時閃爍)
:Handset recording mode :Microphone recording mode
Auto:Auto recording mode Manual:Manual recording mode
Trigger:Voice Trigger mode :Loop recording mode
10H:Recording time of remaining capacity Time:System Time
(B)Talk Mode
Type:Incoming 、Outgoing 。
Elapse:Talking time。
Phone number:Incoming/Outgoing phone number 。
7 Setup
(A)Answer Machine
1 .Play Greeting:
Play a greeting message to callers.
2. Record Greeting:

DUET Operate Instruction
7
Record a greeting
3 .Remote Access Code:
Set password for remote access. The default setting is 111。
4 .Number of rings before the unit answers a call:
You can change the number of times the phone rings “Ring Count” before the
unit answers calls. You can select 2 to 7 rings.
※Toll saver- The unit’s answering system answers at the end of the 2nd ring
when new messages have been recorded, or at the end of the 4th ring when
there are no new messages.
5. Enable the Answering System Remotely
If the answering system is off, you can enable it by ringing it on remotely.
Setting range is 5-20 times
6 .Messages Monitor Setting:
When this function is enabled, you may listen to message synchronously.
Default setting is disable
7 .Caller’s Recording Time:
You can change the maximum message recording time allotted to callers. You
can also select “Greeting only” which set the unit to greet callers but not record
messages. The range is 2-5 minutes.
(B).Recording Parameter

DUET Operate Instruction
8
1 .MIC REC Mode :
Switch the SOURCE to MIC, AR120 can record audio from built in
microphone or external microphone.
(1)Manual
Press RECORD to start, STOP to terminate.
(2)Automatic (Voice Trigger)
When voice level is higher than settings, it starts recording automatically.
2. Auto / Manual Rec.
You can set channel recording conditions
(1)Manual Recording
Press RECORD to start, STOP to terminate
(2)Automatic Recording
When line voltage is lower than settings, it starts recording automatically
(3)Voice Trigger
When voice level is higher than settings, it starts recording automatically.

DUET Operate Instruction
9
3 .VOX Trig Level
Adjust voice level in voice trigger conditions. Setting range is 1-10.
4. VOX Silence
Adjust silent time to terminate recording in voice trigger conditions. Setting
Range is 5-99 sec
5. Max REC Duration
Set maximum recording time for single call. Setting range is 10 min ~ ∞
6. Min REC Duration
Set minimum recording time for single call. Setting range is 5 sec ~ ∞
7 .Loop Recording
(1)Enable
When the SD card capacity is insufficient, it will delete the old audio files
automatically and keep recording.
(2)Disable
When the SD card capacity is insufficient, it will not record any more.
8. Storage Capacity Alert
The LCD remaining recordable time symbol will blink when storage capacity
is lower than setting. Setting range is 5-99 hours.
9. Play Announcement
Enable / Disable to play announcement that the call is recorded to caller
10. off Hook Voltage
The system will record the call automatically when the line voltage is lower
than setting. Setting range is 15~30(V).
11. Call out Delay Time
The system will record calls after setting delay time.Setting range is 0~20
sec
(C) .System Setup
Table des matières