8. If the air conditioner is not used for prolonged periods, disconnect the pipe and plug the window unit.
Connect the power cord to a suitable electric socket (220–240 V). Insert the supplied batteries into the remote control and
make sure the poles match. Select the desired operating mode from the remote control.
HOW TO USE THE APPLIANCE
This appliance can be used for cooling, dehumidifying and ventilating.
When switching between modes, the fan continues to rotate but the compressor stops: the compressor will start after 3
minutes. This delay protects the compressor from potential damage.
Cooling, Fan Dehumidifying
THE DISCHARGE TUBE MUST ALWAYS BE CONNECTED to the appliance: the only exception is when the
appliance is used solely for dehumidification, in which case it is advisable to let the appliance discharge
directly into the environment for maximum efficiency (consult the "Dehumidification Mode" paragraph).
Regularly clean the air filters beneath the easily removable rear grille to keep the air conditioner working efficiently.
OPERATING MODES
1. COOLING MODE (COOL)
Press the MODE button to select Cool mode
The "Cool" LED on the control panel will turn on.
The temperature can be adjusted to between 16 °C and 30 °C.
In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the temperature
setting and, when switched back on again, retains this setting.
In this mode, the fan speed can be adjusted and the Timer and SLEEP functions can be set.
For more silent operation, run the fan at low speed.
Under cooling mode, when the set point is reached, turns off, and internal fan motor(the upper one) keeps operation
continuously at set fan speed; the external fan motor(the lower one)continues the operation at low fan speed
2. DEHUMIDIFICATION MODE (DRY)
Press the MODE button to select Dry.
The temperature is controlled by the PCB and cannot be regulated.
In this mode, whenever the ON/OFF button is pressed, the unit switches off, the appliance saves the settings
and, when switched back on again, retains them.
The fan speed is set to low and cannot be adjusted.