FCC Compliance
This equipment complies with relevant portions of Parts 2, 73, & 74 of the FCC rules
governing LPTV operation.
Disclaimer
Information provided by Anywave Communication Technologies is believed to be accurate
and complete; however, no liability can be assumed for its use.
The manufacturer makes no representations or warranties, either expressed or implied, by or
with respect to anything in this manual, and shall not be liable for any implied warranties of
fitness for a particular purpose or for any indirect, special, or consequential damages.
Information in this document is subject to change without notice and does not represent a
commitment on the part of the manufacturer.
USE OF THIS PRODUCT IN A MANNER OTHER THAN DESCRIBED IN THIS
MANUAL MAY RESULT IN DAMAGE TO THE EQUIPMENT AND/OR PERSONAL
INJURY.
PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE ATTEMPTING TO
INSTALL THE EQUIPMENT. CONTACT ANYWAVE WITH ANY QUESTIONS OR
CONCERNS YOU MAY HAVE.
Anywave Communication Technologies Inc.
300 Knightsbridge Parkway, Suite 150, Lincolnshire, IL 60069
Tel: (847) 415-2258
Fax: (847) 415-2112
http://www.anywavecom.com/en/

ACT-5X+ Exciter User Manual
Version 1.1 5/8/2015 Page 3 of 33
Unpacking
Carefully unpack the equipment and perform a visual inspection to determine if any apparent
damage has occurred during shipment. Please notify the delivery carrier and Anywave
immediately if shipment damage has occurred. Retain all original shipping materials.
Please locate and reference the Packing Check List to verify you have received all
components of your system. Retain the Packing Check List for future reference.
Also, please identify and remove all packing materials and supports (foam pads, etc.) prior to
initial turn on of the equipment.
Returns and Exchanges
Written approval and a Return Authorization Number (RAN) are required from Anywave for
all equipment returns. Please direct all return inquiries to the Anywave Service Department at
[email protected], providing the Sales Order number and Serial Number(s) of
the equipment. Complete details regarding the nature and circumstances of your return must
be included in your RAN request. Proper handling and return shipping instructions will be
provided with an approved RAN number.
Technical Support
Technical support and troubleshooting assistance for Anywave Transmitters is available
through the Anywave Service Department during normal business hours (8:00 AM - 5:00 PM
CST) at (847) 415-2258.Email questions to support_us@anywavecom.com.
Note: For all service and support requests, you will need to provide the Serial Number of the
equipment with your Sales Order number. For future reference, please record that information
here:________________________________________

ACT-5X+ Exciter User Manual
Version 1.1 5/8/2015 Page 4 of 33
WARNING
THE VOLTAGES, CURRENTS, AND RF ENERGY IN THIS EQUIPMENT ARE
DANGEROUS. PERSONNEL MUST AT ALL TIMES OBSERVE ALL SAFETY
WARNINGS, INSTRUCTIONS, AND REGULATIONS.
IN THE CASE OF EMERGENCY, ENSURE THAT ALL POWER HAS BEEN
DISCONNECTED.
ALWAYS DISCONNECT POWER BEFORE REMOVING COVERS,
ENCLOSURES, OR SHIELDS. DO NOT PERFROM SERVICE ON THE
EQUIPMENT WHEN ALONE OR FATIGUED. KNOW YOUR EQUIPMENT AND
DO NOT TAKE RISKS.
This manual is provided as a general guide for trained and qualified personnel well aware of
the dangers inherent in handling potentially hazardous electrical transmission equipment.
The installation, operation, maintenance and service of this equipment involves risks both to
personnel and equipment, and must ONLY be performed by qualified personnel exercising
due care. Anywave Communication Technologies, Inc. shall not be responsible for injury or
damage resulting from improper handling or from the use of improperly trained or
inexperienced personnel performing such tasks.
All local building and electrical codes as well as fire protection standards must be observed in
the installation and operation of the equipment.

ACT-5X+ Exciter User Manual
Version 1.1 5/8/2015 Page 5 of 33
Contents
1 Product Appearance ..........................................................................................6
1.1 Front Panel.....................................................................................................6
1.2 Back Panel .....................................................................................................7
2 Operation Specifications...................................................................................8
3 Menu...............................................................................................................11
3.1 Initialization.................................................................................................11
3.2 Query Mode.................................................................................................11
3.3 User Menu....................................................................................................13
3.4 Advanced Menu ...........................................................................................19
3.4 Web Interface...............................................................................................23
4 Connections.....................................................................................................26
4.1 Connect the Transmitter...............................................................................26
4.2 Start ADPC function ....................................................................................26
4.3 Connections for TSoIP (option)...................................................................27
5 Troubleshooting ..............................................................................................29
5.1 TS Input (Exciter Mode)..............................................................................29
5.2 Tuner Input (Translator Mode) ....................................................................29
5.3 GPS (option) ................................................................................................30
5.4 ADPC...........................................................................................................30
5.5 Other Problems ............................................................................................31

ACT-5X+ Exciter User Manual
Version 1.1 5/8/2015 Page 6 of 33
1 Product Appearance
1.1 Front Panel
LCD:
40×2 LCD with power saving backlight
6 Buttons:
Left, Right, Up, Down, OK, ESC
6 LEDs:
When in Exciter mode:
LED_TS1: Green light on indicates TS1 is selected and the input TS signal is OK
LED_TS2: Green light on indicates TS2 is selected and the input TS signal is OK
LED_TSErr: Red light on indicates the selected input signal has error (Refer to Chapter 5)
When in Translator mode:
LED_ TS1: Green light on indicates the synchronization of input RF signal is OK
LED_TS2: Green light on indicates the equalization of input RF signal is OK
LED_TSErr: Red light on indicates there is synchronization error or equalization error
In both Exciter and Translator mode:
LED_ GPS: Green light on indicates GPS connected and locked
LED_ RFON: Green light on indicates system ready and RF on
LED_ SysErr: A flashing red LED indicates the presence of a system error (Refer to Chapter 5)
A solid red LED indicates the unit is in "Local (LCL)" control mode, and when this
LED is off, this indicates that the unit is in "Remote (RMT)" control mode
1 BNC connector:
RFMON: RF monitoring port of after filter feedback signal.

ACT-5X+ Exciter User Manual
Version 1.1 5/8/2015 Page 7 of 33
1.2 Back Panel
RF_IN_A: Feedback signal for SNR/IMD displayed and AGC RF feedback option,
sampled after the band-pass filter (-5 to -15dBm)
RF_IN_B: Feedback signal, sampled before the band-pass filter (-5 to -15dBm)
AGC_IN: AGC DC feedback option (0-5VDC)
RF_MON: Loop out of [RF_OUT] for monitoring (10 dB below RF_OUT)
RF_OUT: Main RF signal output (nominal 0 dBm output)
DIO/TOD IN (RS232): Digital IO for remote control
REMOTE 1(RS232): Serial port for remote control
REMOTE2 (RJ45-B): 10M/100M Ethernet for remote control with SNMP support
TSoIP (RJ45-A): TS over IP input connection (use of this input is an option)
10M_IN: 10 MHz input from external GPS receiver
1PPS_IN: 1 PPS input from external GPS receiver
10M OUT: 10 MHz output from the exciter
1PPS OUT: 1 PPS output from the exciter
TS_IN_1A: The first port of TS inputs, DVB-ASI only
TS_IN_1B: The second port of TS inputs, DVB-ASI only
TS_OUT: TS Loop out of ASI input
TUNER_IN: Received RF signal input
GPS ANT External GPS Antenna Connection
TSoIP OUT: Output of the TS over IP converter to be connected to TS IN 1A when TS
over IP option is installed

ACT-5X+ Exciter User Manual
Version 1.1 5/8/2015 Page 8 of 33
2 Operation Specifications
Environment
Operating Temperature: -10 ~ 50 oC
Operating Humidity: ≤95%
Atmospheric Pressure: 86 kPa ~ 106 kPa
Power Supply
Voltage: 88 ~ 264 VAC
Frequency: 50 / 60 Hz
Inputs/Outputs
RF_IN_A /RF_IN_B (AGC RF Feed-Back option via RF IN A)
Connector: BNC female
Impedance: 50 Ω
Level: -30 dBm ~ 0 dBm
Recommended range: -15 dBm ~ -5 dBm
Location: Back Panel
AGC_IN (AGC DC Feed-Back option)
Connector: BNC female
Impedance: 50 Ω
DC Voltage: 0 V ~ 5 V
Location: Back Panel
RF_OUT
Connector: N-type female
Impedance: 50 Ω
Level: -25 dBm ~ +5 dBm
VSWR: > 15 dB
Location: Back Panel
RF_MON (loop out of [RF_OUT])
Connector: BNC female
Impedance: 50 Ω
Level: 10 dB below [RF_OUT]'s output level
Location: Back Panel
10M_IN
Connector: BNC female
Impedance: 50 Ω
Level: AC-coupled, VP-P ≥300 mV
Location: Back Panel

ACT-5X+ Exciter User Manual
Version 1.1 5/8/2015 Page 9 of 33
1PPS IN
Connector: BNC female
Impedance: 50 Ω
Level: 3.3 V-TTL
Input trigger: Positive Transition
Location: Back Panel
10M OUT
Connector: BNC female
Impedance: 50 Ω
Level: 0 dBm
Location: Back Panel
1PPS OUT
Connector: BNC female
Impedance: 50 Ω
Level: 3.3 V-TTL
Location: Back Panel
TS_IN_1A/ TS_IN_1B
Connector: BNC female
Impedance: 75 Ω
Level: See Table 1
Location: Back Panel
TS_OUT
Connector: BNC female
Impedance: 75 Ω
Location: Back Panel
TUNER_IN
Input level range: -80 dBm ~ - 15 dBm
Input connector: BNC female, 50 Ω
TSoIP OUT
Connector: BNC female
Impedance: 75 Ω
Location: Back Panel
GPS ANT
Connector: BNC female
Impedance: 50 Ω
Location: Back Panel
Table 1 ASI Input Specifications
No
Content
Unit
Value
1
Input Level
mv
200
2
Positive Transition (20%~80%)
ps
1200

ACT-5X+ Exciter User Manual
Version 1.1 5/8/2015 Page 10 of 33
3
Negative Transition (20%~80%)
ps
1200
4
Deterministic Jitter
%
10
5
Random Jitter
%
8
Note
1) The electrical interface characteristics are measured under normal conditions. Values may vary.
2) Operating in abnormal conditions may result in damage to the equipment. Long operating hours in
severe environments may reduce the reliability of the entire system, which may cause permanent
damage to equipment. Make sure all electrical interface characteristics and environmental parameters
are within the defined range listed above before operating this equipment.
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Anywave Dictionnaire électronique