AmazonBasics B073Q48YGF Manuel utilisateur

B073Q48YGF, B073Q3BSPG
Standby UPS 600VA 360W, 8 Outlets,
Standby UPS 800VA 450W, 12 Outlets
UPS De Respaldo, 600VA 360W, 8 Tomas,
UPS De Respaldo, 800VA 450W, 12 Tomas
Alimentation Sans Interruption (ASI) 600 VA 360 W,
8 Prises,
Alimentation Sans Interruption (ASI) 800 VA 450 W,
12 Prises
K01-1198006-00
800VA
600VA

English ..................................... 3
Español.................................. 13
Français ................................. 22

3
Welcome Guide •English
Standby UPS 600VA 360W, 8 Outlets,
Standby UPS 800VA 450W, 12 Outlets
Contents:
Before getting started, ensure the package contains the following components:
Description
Circuit Breaker
Push to Reset
600VA
Surge Protection
Battery Backup & Surge Protection
600VA
800VA
Surge Protection
Battery Backup & Surge Protection
800VA
Circuit Breaker
Push to Reset

4
Basic Operation
1. Battery and Surge Protected Outlets
The unit has several battery and surge protected outlets (4 for 600VA and 6 for 800VA unit)
to ensure temporary uninterrupted operation of your equipment during a power failure. (Do
not plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump or
other large electrical device into the “Battery and Surge Protected Outlets.” The power
demands of these devices will overload and possibly damage the unit.).
2. Full-Time Surge Protection Outlets
The unit has several surge suppression outlets (4 for 600VA and 6 for 800VA unit) to provide
surge and line noise protection.
3. Power Switch
To turn the UPS on, press the power button for approximately 2 seconds - you will hear a
constant tone (1 second) - and release after a short beep.
To turn the UPS off, press the power button for approximately 2 seconds - you will hear a
constant tone (1 second) - and release after two short beeps.
Quickly press the POWER button twice can turn off or turn on the audible Alarm. The default
setting is for the Alarm On.
To turn the alarm off, press the power button twice. You will hear two short beeps when the
alarm is turned off.
To turn the alarm back on, press the power button twice. You will hear a short beep when the
alarm is turned on.
*When the alarm is turned off, no audible notification when the UPS reaches a (low)
battery state.
4. Power On Indicator (green)
This LED is illuminated when the utility power is normal and the UPS outlets are providing
power, free of surges and spikes. When In the event of a complete power loss, severe
brownout, or over-voltage, the UPS will turn to battery mode and the LED will flash.
Please refer to the following “Definitions for Illumination LED Indicators” for more information.
5. Circuit Breaker
Located on the side of the UPS, the circuit breaker serves to provide overload and fault
protection.
6. USB Port to PC
The USB port allows connection and communication between the USB port on the personal
computer and the UPS unit. The UPS communicates its status to the Power Management
Software.
7. Outlets Designed for AC Adapters
The UPS unit has several widely-spaced outlets (2 for 600VA and 4 for 800VA unit), so AC
power adapters can be plugged into the UPS without overlapping or blocking adjacent outlets.

5
Important Safety Warnings
(SAVE THESE INSTRUCTIONS)
• This manual contains important safety instructions. Please read and follow all instructions
carefully during installation and operation of the unit. Read this manual thoroughly before
attempting to unpack, install, or operate your UPS.
• CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity
controlled indoor area free of conductive contaminants. (Please see specifications for
acceptable temperature and humidity range).
• CAUTION! To reduce the risk of electric shock, do not remove the cover. There are no user
serviceable parts inside.
• CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input
power is disconnected.
• CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker
protection. Do not plug into an outlet that is not grounded. If you need to de-energize this
equipment, turn off and unplug the unit.
• CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source
before installing a computer component.
• CAUTION! Not for use in a computer room as defined in the Standard for the Protection of
Electronic Computer/Data Processing Equipment, ANSI/NFPA 75.
• CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes
maximum branch circuit over current protection in accordance with the National Electric Code,
ANSI/NFPA 70.
• CAUTION! Risk of explosion if battery is replaced by an incorrect type. Batteries shall be
installed by service personnel, and the replacement of batteries with a suitable recommended
type. Dispose of used batteries according to the instructions.
• CAUTION! Do not dispose of batteries in a fire. The batteries may explode.
• CAUTION! Do not open or mutilate batteries. Released electrolyte is harmful to the skin and
eyes. It may be toxic.
• DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! AmazonBasics does not
sell products for life support or medical applications. Do not use in any circumstance that would
affect operation and safety of life support equipment, any medical applications or patient care.
• DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not
use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.

6
• DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric
shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock
or vibration caused during transit and the damp environment can cause the unit to short out.
• WARNING! This product contains chemicals known to State of California to cause cancer and
birth defects or other reproductive harm.
• CAUTION! Not for use in a computer room as defined in Standard for the Protection of
Electronic Computer/Data Processing Equipment, ANS/NFPA 75.
Installing Your UPS System
Unpacking
Inspect the UPS upon receipt. The box should contain the following:
(a) UPS unit (b) User’s manual (c) USB Cable
*Power Management software is available on our website. Please visit amazon.com and go
to the product page for free download.
How To Determine The Power Requirements Of Your Equipment
1. Ensure that the equipment plugged into the UPS does not exceed the UPS unit’s rated capacity
(600VA / 360W for AmazonBasics Standby UPS 600VA, 800VA/450W for AmazonBasics
Standby UPS 800VA). If the rated capacities of the unit are exceeded, an overload condition
may occur and cause the UPS unit to shut down or the circuit breaker to trip.
2. There are many factors that can affect the amount of power that your electronic equipment will
require. For optimal system performance, keep the load below 80% of the unit’s rated capacity.
Hardware Installation Guide
1.
Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to
ensure the battery’s maximum charge capacity, it is recommended that you charge the battery
for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged
into an AC outlet, the battery will automatically charge whenever it’s turned on or turned off.
2. With the UPS unit turned off and unplugged, connect your equipment requiring battery backup
into the battery power supplied outlets. Plug the other peripheral equipment (printer, scanner,
speakers) into the full-time surge protection outlets. Do not plug a laser printer, paper
shredder, copier, space heater, vacuum, sump pump or other large electrical device into
the “Battery and Surge Protected Outlets”. The power demands of these devices will
overload and possibly damage the unit.

7
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet).
Make sure the wall branch outlet is protected by a fuse or circuit
breaker and does not service equipment with large electrical demands
(e.g. air conditioner, refrigerator, copier, etc.). The warranty prohibits the
use of extension cords, outlet strips, and surge strips in conjunction
with the UPS.
4. Press the power switch to turn the unit on. The Power On indicator will illuminate green and the
unit will “beep” twice.
5. If an overload is detected, an audible alarm will be sounded and the unit will emit long beep.
To correct this, turn the UPS off and unplug at least one piece of equipment from the battery
power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store the UPS for an extended period of time, cover it and store with the battery fully
charged. While in storage, recharge the battery every three months to ensure battery life.
8. For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be
easily accessible.
9. Do not lay the UPS on its side and please follow the direction as below to mount the UPS to
ensure the battery life.
600VA
800VA
600VA 800VA

8
Denitions For Illuminated LED Indicators
Power ON Alarm
CONDITION
On Off Normal
Flash when
Beeps
Beeps twice every
30 seconds
Utility Failure - Battery Mode
The UPS is providing power to battery and surge
protected outlets from its battery.
Flash when
Beeps
Rapid Beeping
every 1/2 second
Utility Failure - Low Battery
The UPS is providing battery power. Rapid beeping
indicates the unit will run out of power shortly.
On Constant tone
Overload -Occurs when connected equipment
exceeds the listed capacity of the UPS. Turn the
UPS off, unplug at least one piece of equipment from
battery outlets, reset the circuit breaker and turn the
unit on.
Off Constant tone Charge Fault -In line mode, the battery charging
voltage is too high or too low.
Off Constant tone Utility Failure - The frequency is beyond 47-63 Hz.
The UPS will not turn on in line mode.
Technical Specications
Model Standby UPS 600VA Standby UPS 800VA
Capacity 600 VA / 360 W 800 VA / 450 W
Input Voltage on Utility 96V typical - 140V typical
Input Frequency 50/60 ± 3 Hz (Auto-sensing)
Nominal Input Voltage 120 VAC
On-Battery Output Voltage 120 VAC ± 8 %
On-Battery Output Frequency 50 Hz / 60 Hz ± 1 %
Transfer Time 8 ms Typical
Max. Load for UPS Outlets 600 VA / 360 W 800 VA/450 W

9
Model Standby UPS 600VA Standby UPS 800VA
Max. Load for Full-Time Surge
Protection outlets 10 Amps
On-Battery Output Wave Form Simulated Sine Wave
Operating Temperature + 32 °F to 104 °F / 0 °C to 40 °C
Operating Relative Humidity 0 to 95% non-condensing
Size (L x W x H) 10.7 x 3.1 x 6.1 in.
(272 x 80 x 155 mm)
12.2 x 3.1 x 7.0 in.
(310 x 80 x 178 mm)
Net Weight 6.53 lbs (2.96 kg) 9.23 lbs (4.18 kg)
Typical Battery Recharge Time 8 hours typical from total discharge
Typical Battery Life 3 to 6 years, depending on number of discharge/
recharge cycles
Recommended Battery Sealed Maintenance Free Lead Acid Battery
Safety Approvals UL, cUL, FCC Class B, ICES-003: Class B, CEC
System Function Block Diagram
Input
Output
EMI Filter
Battery Inverter
Surge
Suppressor
Charger
AC / DC
Normal Mode
Battery Mode

10
Troubleshooting
Problem Possible Cause Solution
Full-time surge protection
outlets stop providing power
to equipment. Circuit breaker
button is projecting from the
side of the unit.
Circuit breaker has
been tripped due to an
overload.
Turn the UPS off and unplug at
least one piece of equipment.
Wait 10 seconds, reset the
circuit breaker by pressing
the button, and then turn the
UPS on.
The UPS does not perform
expected runtime.
Battery not fully
charged.
Recharge the battery by leaving
the UPS plugged in.
Battery is worn out. Please contact Amazon about
replacement batteries.
The UPS will not turn on.
The on/off switch is
designed to prevent
damage from rapidly
turning it off and on.
Turn the UPS off. Wait
10 seconds and then turn the
UPS on.
The unit is not
connected to an AC
outlet.
The unit must be connected to a
110/120 V 50/60 Hz outlet.
The battery is worn out. Please contact Amazon about
replacement batteries.
Mechanical problem. Please contact Amazon.
The frequency is
outside of the operating
range of 47-63 Hz.
Turn the UPS off. Make sure the
frequency range is within
47-63 Hz. Or you can turn the
UPS on in battery mode.
Ce manuel convient aux modèles suivants
1
Table des matières
Langues :
Autres manuels AmazonBasics UPS
Manuels UPS populaires d'autres marques

Pylontech
Pylontech Victron & Pylontech US5000 Manuel utilisateur

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manuel utilisateur

Mecer
Mecer ME-1000-WTU Manuel utilisateur

Mustek
Mustek PowerMust 530(B) Plus Manuel d'installation et d'exploitation

Emerson
Emerson Liebert NXL series Manuel utilisateur

MAKELSAN
MAKELSAN BOXER SERIES Manuel utilisateur