Allegion interflex IF-4076-0 Manuel utilisateur

IF-4076-0
Access Manager
Controller
00-4076-04xx

Table of contents
© 2021 Interflex Datensysteme GmbH IF-4076-0 Access Manager 2
Table of contents
1 General information.......................................................................................................................... 3
1.1 Short description ......................................................................................................................... 3
1.2 Scope of delivery ........................................................................................................................ 3
1.3 Target group ............................................................................................................................... 3
1.4 Intended use ............................................................................................................................... 4
1.5 Safety.......................................................................................................................................... 4
1.6 Abbreviations .............................................................................................................................. 4
1.7 Cable lengths and cable types.................................................................................................... 5
2 System overview............................................................................................................................... 5
2.1 Access manager overview .......................................................................................................... 6
2.2 IF-4070 controller overview......................................................................................................... 9
3 Installing the access manager......................................................................................................... 11
4 Connecting the access manager..................................................................................................... 11
4.1 Cable routing............................................................................................................................... 11
4.2 Wiring components ..................................................................................................................... 12
4.3 Connecting the controller ............................................................................................................ 16
5 Initial operation ................................................................................................................................. 17
5.1 Connecting the controller to the network .................................................................................... 17
5.2 Checking and setting network parameters.................................................................................. 19
5.3 Configuring the interfaces and the booking memory .................................................................. 20
5.4 Listing the configuration data of slave terminals ......................................................................... 22
5.5 Restarting the controller.............................................................................................................. 23
6 Updating the software ...................................................................................................................... 25
7 Upgrading the controller.................................................................................................................. 25
8 Technical specifications .................................................................................................................. 26
8.1 General ....................................................................................................................................... 26
8.2 IF-4070........................................................................................................................................ 26
9 Disposal............................................................................................................................................. 27
10 EU Declaration of Conformity.......................................................................................................... 27

1 General information
© 2021 Interflex Datensysteme GmbH IF-4076-0 Access Manager 3
1 General information
1.1 Short description
The IF-4076-0 access manager in metal housing with an integrated
IF-4070 controller is used to accommodate up to 16 I/O controller
boards and serves as a link between the host system and a maximum
of 16 terminals (slaves) of the IF-7xx/IF-8xx series.
1.2 Scope of delivery
The package contains:
nHousing with integrated IF-4070 controller, supporting plate for I/O controller boards and power
n
n
n
n
n
supply unit
Cable gland, M20 x 1.5
Strain relief plates with screw nuts
Split ferrite
Accessory bag with screws, screw anchors and a key for the bolt lock
95-10436 product Info
Check the completeness and condition of the goods upon receipt and report any damage caused
during transport immediately.
1.3 Target group
This document is solely intended for experts and people trained in electrical engineering.
Only perform the actions described in this document if you belong to this target group. Interflex
Datensysteme GmbH is not liable for any damages caused by improper installation or initial
operation.

1 General information
© 2021 Interflex Datensysteme GmbH IF-4076-0 Access Manager 4
1.4 Intended use
The access manager in a wall-mounted housing is used to transmit recorded data from the readers to the
access control system and to control doors.
Any other use is not in accordance with the intended purpose and therefore not permitted. Modifications
to the device are not permitted.
1.5 Safety
WARNING
Danger to life due to electric shock
People can be seriously hurt or killed through physical contact with live parts (e.g. 230V~).
uMake sure that you cannot touch live lines during installation.
uSwitch off the power supply of the devices.
uPlease observe the applicable safety regulations and take all precautionary measures to ensure safe
installation.
NOTICE
Property damage due to transient overvoltages
Transient overvoltages (surges, bursts) in the energy supply network can lead to malfunctions and
failures.
uUse suitable mains filters that are professionally installed and operated.
NOTICE
Damage due to electrostatic discharge (ESD)
Electrical components and modules can be damaged by only slight, hardly noticeable electrostatic
discharge (ESD) without this becoming immediately obvious. ESD damages result in malfunctions and
even failure of the product.
uMake sure that effective protective measures against electrostatic discharge are in place when
working on the open device.
1.6 Abbreviations
AC Alternating Current
BLE Bluetooth Low Energy
CIDR Classless Inter-Domain Routing
DC Direct Current
DIP switch Switch in IC design, connections in two rows (Dual In-line Package)
EMC Electromagnetic Compatibility

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4076-0 Access Manager 5
ESD Electrostatic discharge
GND Ground
IEEE Institute of Electrical and Electronics Engineers
NC contact Normally closed contact
NO contact Normally open contact
PoE Power over Ethernet
RFID Radio-Frequency Identification
SH Shield
SSH Secure shell
1.7 Cable lengths and cable types
Cable Function Max. Length Recommended cable type
230 V AC power supply to power supply unit (if not
pre-installed)
NYM 3 x 1.5mm2
Network cabling: RJ45 patch cable, preferably shield
braiding
100m From category 5
Cable to floating status contacts, control cable 100m J-Y(St) Y 2 x 2 x 0.6mm2
J-Y(St) Y 2 x 2 x 0.8mm2
RS485 bus cable to parent or child devices 1200m J-Y(St) Y 2 x 2 x 0.6mm2
J-Y(St) Y 2 x 2 x 0.8mm2
RS485 branch cable to bus cable 100m J-Y(St) Y 2 x 2 x 0.6mm2
J-Y(St) Y 2 x 2 x 0.8mm2
Connecting cable between I/O controller board and
slave terminal
100m J-Y(St) Y 4 x 2 x 0.6mm2
J-Y(St) Y 4 x 2 x 0.8mm2
In long cables, voltage losses can impair the functionality of the connected device. Therefore, do not use
cables longer than specified in the table. Wire the +5 V and GND lines with two cores each for a cable
length > 50 m.
2 System overview
The IF-4076-0 access manager includes the following functions:

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4076-0 Access Manager 6
nOperation in conjunction with a host system for access control or time recording (e.g., IF-6020 or
IF-6040)
nConnection and control of up to 16 slave terminals via I/O controller boards
nRecording of bookings (IN, OUT, absences, access)
nAccess control including door control and monitoring
nStorage of data required for offline operation, e.g. credential numbers, temporal and local permissions
In offline mode, the access manager takes over the functions of the host system. It checks and
acknowledges booking permissions during identification procedures at slave terminals.
2.1 Access manager overview
Electronic assembly units
The I/O controller boards are included in scope of delivery of the slave terminals.
The cables on bus 1 of the IF-4070 controller are fed through a split ferrite (not shown in the
figure).

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4076-0 Access Manager 7
1
2
3
4
5
6
7
8
1IF-4070 controller
2Anti-tamper switch
3Mounting rail for fastening additional power supply units
4Strain relief for voltage feed
5Ground
6Voltage filter with fuse
7Transformer
8Supporting plate for up to 16 I/O controller boards
The anti-tamper switch 2 can be configured in such a way that it is monitored by the host
system and triggers an alarm when the housing is opened.
1. Before opening an access manager that has already been put into operation, deactivate the
alarm
2. Reactivate the alarm after work has been completed
Detailed information on this subject can be found in the documentation of the host system

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4076-0 Access Manager 8
Components
3
6
7
5
8
1
4
2
1Host system 2IF-4070 controller
3Slave Terminal 4Readers
5Control element 6Door opening push-button
7Door contact 8Power supply

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4076-0 Access Manager 9
2.2 IF-4070 controller overview
Connections on the printed circuit board
11 8
1235
7
10
12
13
4
15
14
6
9
1USB connection (for future use)
214-pin screw terminal for floating status contacts
314-pin screw terminal for floating status contacts and relay contacts
414-pin screw terminal for relay contacts
56-pin screw terminal for relay contacts
6Connection for optional rechargeable battery for emergency power supply (IF-4070 only)
7Screw terminal for the connection of the power supply
8RJ45 socket for the connection to the Ethernet network (host system)
9USB connection (for future use or ServiceApp)
10 3x RJ45 sockets with RS485 interfaces for the connection of bus data cables 1, 2, 3
11 RJ45 socket with RS485 interface for the connection to the host system
12 RJ45 socket with RS232 interface for the connection to the host system
13 RJ45 socket with RS232 interface for the connection of a service device
14 3-pin screw terminal for RS232 service cable (same function as socket 13)
15 7-pin screw terminal for RS485 data cable (same function as socket 10)

2 System overview
© 2021 Interflex Datensysteme GmbH IF-4076-0 Access Manager 10
Table des matières
Autres manuels Allegion Contrôleurs d'accès IP