AKCP SP+ Series Manuel du propriétaire

www.AKCP.com
SP+ Security Features Manual
Copyright © 2017, AKCP

SP+ Security Features Manual
- 2 -
Table of Contents
Introduction ................................................................................................................................................... 3
Services..........................................................................................................................................................4
SSL Certificate..................................................................................................................................5
SNMPv3..........................................................................................................................................................8
Password Checking and Security ............................................................................................................... 9
Password Security options.............................................................................................................10
Lockdown ............................................................................................................................ 11
Password Expiration...........................................................................................................12
Access Control Users and Groups .............................................................................................................13
Server Integration ......................................................................................................................................... 14
VPN to APS....................................................................................................................................................15
Troubleshooting - How to generate a proper .PEM file from a Windows CA..........................................16

SP+ Security Features Manual
- 3 -
Introduction
The security features on the sensorProbe+ units allows users to lock down and secure the unit from
exterior threats. Each option will be covered in detail within this manual.
Services - enable/disable HTTP and HTTPS, and change their ports
SSL Certificate - ensure the identity of the unit for HTTPS and SNMPv3 communication
SNMPv3 - secure SNMP traffic
Password Checking and Security - manage the access to the unit‟s Web UI, set password
expiration and lockdown features
Server Integration - enable/disable controlling the unit via AKCess Pro Server, and the access
control user sync
VPN to APS - connect the SP+ with an APS VPN server securely

SP+ Security Features Manual
- 4 -
Services
You can close or change the ports used to access the unit‟s web interface, disable HTTP and enable
HTTPS only, which can also be set to be used as default.
On the SP+ family, the HTTPS supports TLS v1.1 and v1.2.
The HTTPS cypher suites are not customizable.
Using the “Upload Certificate File” option you can upload an SSL certificate that will be used by the
unit‟s Web UI for HTTPS connection.

SP+ Security Features Manual
- 5 -
SSL Certificate
SSL certificates are generated for DNS host names and not IP addresses. You should set a host
name for the SP+ unit in your local DNS server or DHCP server, and then generate the SSL
certificate for that host name.
Example: spplus.mycompany.org
The unit‟s DNS host name is “spplus”. Wildcard SSL certificates should also work, but this hasn‟t
been tested.
If the name doesn‟t match with the one in the certificate, the browser will still show a security warning.
You can purchase a certificate from a trusted, verified Certificate Authority such as GoDaddy or use
your company‟s own CA if you have one.
Please note that only non-password protected certificate files are supported.
When you select the file for uploading, you‟ll get a warning if the file is not in .PEM format:

SP+ Security Features Manual
- 6 -
The .PEM file is the private key + certificate combined. You can copy them to one file using
Notepad++ if you have 2 separate files, as shown below (it has to be in Unix Line Format and not
Windows):

SP+ Security Features Manual
- 7 -
If you don‟t upload a certificate but enable HTTPS, a built-in certificate will be used. You‟ll get a
browser warning upon opening the Web UI about an incorrect certificate. This is normal and you
should add it as an exception or proceed, depending on your browser:

SP+ Security Features Manual
- 8 -
SNMPv3
SNMPv3 provides important security features:
* Confidentiality - Encryption of packets to prevent snooping by an unauthorized source.
* Integrity - Message integrity to ensure that a packet has not been tampered with in transit.
* Authentication - to verify that the message is from a valid source.
The SSL certificate that you can upload to the unit will be also used for signing the SNMPv3 traffic.
Please note that this feature requires a separate license and has to be activated before using.
More details can be found for setting up and using SNMPv3 in the SP+ Introduction Manual.

SP+ Security Features Manual
- 9 -
Password Checking and Security
You can turn on the password checking for the Web UI to ensure only authenticated users have
access to the unit. You can also specify to show all user names on the login page, or keep them
confidential.
After you enable the password checking, you‟ll need to re-login.
If you don‟t remember the Admin password, you can hold the unit‟s reset button for 7-12 seconds to
be able to log in to the Web UI without a password.
Note 1: The passwords can only be set from the unit‟s Web UI; this option is not available from APS.
Note 2: The default password is “public” for all access levels.
Web UI user access levels and permissions
Admin - full access to all settings, system and notification configurations
Viewer - read-only guest access for every page
User - full access to most settings except for those which are
the system-related such as network
In detail, the User access level provides these permissions in
addition to the Viewer level:
Allow modifying board/sensor settings
Allow add/modify/remove notifications
Allow add/modify/remove heartbeats
Allow open/close the door on the Handle Lock
Allow send configuration to Support
Allow change Graph settings
Allow change the Web UI language

SP+ Security Features Manual
- 10 -
Password Security options
All user account types (Admin, User, Viewer) have adjustable password expiration and lockdown
periods.
The password can be up to 15 characters (a-z, A-Z, 0-9 and special characters).
The IP address of the remote user‟s computer will be logged in the syslog so you can trace back each
login session to its origin.