AGF Professional 1500 Manuel utilisateur

9 Norfolk Court, Coburg North Victoria 3058
Tel: (03) 9355 7100
Fax: (03) 9355 7166
Email: sales@agradefinish.com.au
Web: www.agradefinish.com.au
AGF Professional 1500
INSTALLATION INSTRUCTIONS
450mm
850mm
1500mm
595mm – 1000mm
300mm
600mm

Index
1. Welcome ................................................ 1
2. Safety ..................................................... 2
3. Item check list ........................................ 2
4. Installation.............................................. 3
5. Operation .............................................. 7
6. Maintenance........................................... 8
7. Technical support ................................. 10
8. Warranty............................................... 10
1. Welcome
Congratulations on you purchase of AGF Professional 1500 Rangehood
Please make sure to read through the installation instructions prior to installing the unit as it
contains important information.
Please make sure you follow these installation instruction as they contain vital safety information.
Be sure to keep your proof of purchase as this will be needed for warranty.
This canopy rangehood is an indoor appliance and has been manufactured and tested to comply
with Australian Standard/New Zealand AS/NZS60335.2.31:2004 inc amendment 1 & 2
The Rangehood is marked with the Regulatory Compliance Mark
to show it has been approved
PAGE 1 AGF Professional 1500

2. Safety
Please read this section prior to operating this unit.
If you find the rangehood is damaged in anyway please
do not install and contact A Grade Finish Canopies ASAP on
(03) 9355 7100.
This appliance is not intended for use by young children or infirm persons without adequate
supervision.
There is a fire risk if cleaning is not carried out in accordance with the instructions.
Do Not Flambé under the rangehood
There should be adequate ventilation of the room when the rangehood is used at the same time
with appliances burning gas or other fuels.
You must read the details concerning the method and frequency of cleaning.
The appliance is supplied with an approved power cable. If the supply cord of this equipment is
damaged, it must only be replaced by the manufacturer, its service agent or similarly qualified
person in order to avoid hazard.
Always switch power off prior to installing, servicing or cleaning the appliance.
3. Item Check list
1. AGF PROFESSIONAL 1500 RANGEHOOD BOX
2. 2 x AGF310 ROOF MOUNT FAN
3. 2 x 1000mm OF SOLID 305MM DUCTING
AGF PROFESSIONAL 1500 RANGEHOOD BOX CONTENTS
• 1 x rangehood (including filters)
• 1 x 2 piece telescopic flu
• 1 x top flu mount bracket
• 2 x 5 meter flexible duct
• 2 x joiner
• 1 x 3 way junction
• 2 x flue support bracket
Not included in box
•All fixings • Roof seal kit (Dektite) • Silicone • Double adapter
AGF Professional 1500 PAGE 2

4. Installation
Step 1:
Open box and check there is no damage
to the rangehood (if there is any damage
please contact a grade finish canopies on
(03) 9355 7100). DO NOT INSTALL.
Step 2:
Mark out the centre of where you wish to
install the rangehood. (Refer figure 1)
Step 3:
Mark out the height that you rangehood is to
be installed at. (Refer figure 2)
Step 4:
Hold rangehood up to the marks (step 2 and 3)
and mark the mounting points.
(Refer
figure 3)
Step 5:
Screw fixings into marks for mounting
Step 6:
Hang the rangehood and tighten to fix to the
wall. (Refer figure 4)
PAGE 3 AGF Professional 1500
Figure 4
Figure 3
Figure 2
Figure 1
NOTE: please refer
to height listed in
safety section

4. Installation continued
Step 7:
Cut a hole in the ceiling above the rangehood
to enable the flexible ducting and power
cables to pass through easily.
Be sure not to make the hole bigger than the
flue cover.
The hole will need to be big enough to be
able to pass the power cables though to the
ceiling.
Step 8:
Installing the solid ducts
For this step you will need to mark out where
the ducting is to pass through the roof.
Make sure that when marking out the location
of the ducting it is next to a beam (for support)
With the location of the ducting confirmed cut
the hole out in the roof to enable the ducting
to pass through the roof leaving 250mm
outside the roof.
Screw the ducting into a beam for support.
Install the flue support bracket to the beam
and screw to the duct. (Refer figure 5 / 6)
Repeat for the second duct.
Please leave a minimum gap of 500mm
between the solid ducts. (Refer figure 7)
AGF Professional 1500 PAGE 4
Step 7
Figure 5
BEAM
Figure 6
Figure 7

4. Installation continued
Step 9:
install the flue cover bracket 150mm down
from the ceiling. (Refer figure 8)
Step 10:
Installing the flexible duct to the solid duct
and connecting the 3 way junction.
Install the joiner to the bottom of the solid
ducts and secure with screws leaving about half
of the joiner out the bottom to allow for the
flexible ducts to connect to. (Refer figure 9)
Connect one end of the flexible duct to the
stating pop on the rangehood. Secure this
with some PVC duct tape. (Refer figure 9)
Pass the flexible duct through the hole in
the ceiling and connect to the 3 way joiner.
Secure with PVC duct tape.
Connect the flexible to the solid ducting and
the 3 way joiner and secure with PVC duct
tape.
If you need to install the flexible duct with
a bend do not make the bend to sharp as
this can restrict airflow. (Refer figure 11 as an
example for correct instalment of bend)
Step 11:
Install the rubber dektite over the solid duct.
Do not fix down at this point refer step 13.
(This can be purchased at additional cost via
our online store: www.agradefinish.com.au)
PAGE 5 AGF Professional 1500
Figure 9 Figure 10
Figure 11
Figure 8

4. Installation continued
Step 12:
Install the motor to the ducting. Slid the flange of the
motor to the outside of the ducting and level the unit.
Once level screw to the ducting. (Refer figure 12)
Step 13:
With the motor now fixed pass the power lead from fan
inside the dektite. (Refer figure 13)
Step 14:
Once cable has been placed inside dektite finish screwing
dekite down and silicon all edges.
Step 15:
Connect male plug from rangehood to main power
supply. (Refer figure 14)
Step 16:
Connect female plug from rangehood to male plug of
double adaptor. (Refer figure 14)
Step 17:
Connect both of the fans to the double adaptor
Step 18:
Installing the flue cover
With both flue pieces connected to each other (smaller
piece to the outside) place on top of rangehood.
Slide the inner piece up to ceiling height and screw into
the mounting bracket installed in step 9. (Refer Image
15/16)
With the top half of the flue now secure you will now
need to secure the bottom piece
Screw the bottom piece to the rangehood and also screw
to the top piece for extra support. (Refer figure 17)
Step 19:
Thank you for purchasing an A Grade rangehood.
Enjoy!
AGF Professional 1500 PAGE 6
Figure 12
Figure 13
Figure 14
Figure 15 Figure 16 Figure 17

5. Operation
Rangehood switch
Power on/off
(Fan will not operate without
power being on)
While fan is running press power
button once to engage the 3
minute timer. Once timer has
completed unit will switch off
(lights will still remain on after timer
has completed). Press the power
button second time to switch unit
off and bypass the timer function.
Filter Removal/Installation
When removing filters use both the handles and slide the filter to the back of the unit. Once you
have the filter at the back of the unit this will enable the filter to release from the rangehood.
To Re-install the filters slide the filter to the back of the unit then slide to the front of the rangehood.
PAGE 7 AGF Professional 1500
Fan low speed
Fan medium speed
Fan high speed
Downlight operation
(power does not need to be on
for downlights to operate)
1. Slide filter to back of rangehood 2. Pull filter down and slide filter towards the front
of the rangehood to release from body
3. To reinsert the filter do steps I and 2 in reverse

6. Maintenance
Please ensure that your unit is turned off prior to conducting any cleaning.
Filters should be cleaned every 3 months or more frequently depending on the use.
NEVER turn the filters around. Handles are to be facing down at all times.
NEVER USE CAUSTIC SODA AS THIS WILL DAMAGE FILTERS
Never wipe unit with a wet cloth as water may affect the electrical switches.
We recommend the use of stainless steel cleaning wipes.
When cleaning your roof, cover roof mount fan with plastic if you are going to use chemicals.
Globe Removal
Ensure unit is turned off prior to replacing globes
1. Rotate the inner globe holder in an anti-clockwise direction
2. Pull the globe holder and globe out and disconnect the globe from the lamp lead
3. Once disconnected from the lamp lead, remove the halogen light from its housing
AGF Professional 1500 PAGE 8
Do not exceed 50 Watts
Do not exceed 50 Watts
Do not exceed 50 Watts

6. Maintenance continued
4. Insert a new globe into the housing, making sure the globe fits nice and tight in the housing.
5. Reconnect the globe and holder to lamp lead.
6. Insert back into housing and turn in clockwise direction to lock into place.
7. Technical Support
For all technical support please contact:
A Grade Finish Canopies
on (03) 9355 7100
or via email info@agradefinish.com.au
PAGE 9 AGF Professional 1500
Do not exceed 50 Watts
Do not exceed 50 Watts
Do not exceed 50 Watts
Autres manuels pour Professional 1500
1
Table des matières
Autres manuels AGF hotte de ventilation