CS1-RL(F) –OPERATION MANUAL(EN)-2013-01-04
In the case of input, the
should set
to display full range of RPM and to get higher
resolution in lower RPM.
●
(Manual range):The decimal point will be
fixed according to the setting of
The meter
will show
(overflow), once the input goes
over the frequency that is relative 99999.
Ex.: RPM of Motor: 7200RPM,Encoder: 1000ppr
as same as above,
The meter setting
:
;
:
:
;
:
The table is between input and display as below,
Freq. Input Display
0Hz
RPM
166.65Hz
RPM
1666.5Hz
RPM
16.665kHz
RPM
16.666kHz
RPM
120kHz
RPM
The input goes down to
16.665kHz
RPM
In the case of input, the
should set
to display full range of RPM.
Time out function
Programmable:
/
In the case of low frequency, the meter can not to
identify that is low frequency and no input until the
next pulse input. Sometimes, it takes a long
period.
The meter builds in a time out function to cut out
the display to be “0”.
There are two modes
/
can be
programmed as below,
●
(Manual): There is a period named
(input time out) can be set from 0.0sec~999.9sec.
The display will be “0”, once the next pulse doesn’t
input during the setting time.
●
(Auto): The display will be “0”, once the next
pulse doesn’t input during the time that gave by
formula of meter’s firmware. Gerenally, the auto
time out is 4 times of 1/ frequency of last input
frequency.
Max / Mini recording
In order to review & trace the drifting PV, the
meters will keep the values of maximum and
minimum in
during power on.
The maximum and minimum can be reset by front
key function. Please refer to the operation on
description as below.
orange LED will be bright during power on, until
Maximum Hold or Minimum Hold for PV
When the
function in
set
to be
(Max. Hold) or
(Mini. Hold), that
the meter will still display the values of PV in
maximum (or minimum) and the relative square
manual reset by front key in
or
Down Key function has been done. The meter will
update immediately new maximum(minimum)
values after press Down Key to reset.
Please paste the sticker
on the right side of
orange square LED to identify the status of display.
Max. ( Mini.) Hold & Reset
Reset the Max
(Mini) Hold by
Down Key
PV(Present value) Hold
When the
set to be
(PV Hold)
function in
, that display will be hold
& kept, and the relative green LED will be bright,
when user press Down Key, until press Down Key
again.
Please paste the sticker
on the
green square LED to identify the status of display.
Reset Data
Hold by
Front Key
Remote display by RS485 command
In past, The meter normally receive 4~20mA or
0~10V from AO card or BCD card of PLC. We
built-in a new solution by RS485 remote display
function which it can save costs of AO and wiring
connecting to PLC simultaneously.
When the
function set to be
, the
LED display no longer relative to the input signal
then the PV screen will show the data from RS485
command.
Low Cut
Settable range from -19999~+29999 counts.
The users can set a value here to cut the display
value to show "0".
●If the setting value is positive, it expressed the
PV will be 0 which it's within the range of
absolute value;
PV< l Setting value l, the display will be 0
EX: Low Cut is set for 0.50, if the display is from
-0.50~+0.50, that will be 0.
point resolution