ADF Web HD67324-B2-E-232-4GB Manuel utilisateur

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 1 of 44
User Manual
Revision 1 200
English
Modbus / CAN – Datalogger
(Order Code: HD67324-B2-E-232-4GB, HD67324-B2-E-485-
4GB,
HD67324-B2-E-CAN-4GB)
for Website information:
www adfweb com?Product=HD67324
for Price information:
www adfweb com?Price=HD67324-B2-E-232-4GB
www adfweb com?Price=HD67324-B2-E-485-4GB
www adfweb com?Price=HD67324-B2-E-CAN-4GB
Benefits and Main Features:
Very easy to configure
Electrical isolation
Temperature range: -40°C/85°C (-40°F/185°F)
For other M-Bus products:
See also the following link:
Converter M-Bus to
www adfweb com?Product=HD67021 (RS232
www adfweb com?Product=HD67022 (RS485
www adfweb com?Product=HD67030 (Ethernet
Extender and Repeater, M-Bus
www adfweb com?Product=HD67032
Gateway M-Bus / Modbus RTU
www adfweb com?Product=HD67029M-232 (on RS232
www adfweb com?Product=HD67029M-485 (on RS485
Gateway M-Bus / Modbus TCP
www adfweb com?Product=HD67044-B2
Gateway M-Bus / CANopen
www adfweb com?Product=HD67051
Gateway M-Bus / PROFIBUS
www adfweb com?Product=HD67053M
Do you have an your customer protocol?
See the following link:
www adfweb com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www adfweb com?Cmd=helpme
User Manual

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 2 of 44
INDEX:
Page
INDEX 2
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
SECURITY ALERT 3
CONNECTION SCHEME 4
CONFIGURATION 7
CHARACTERISTICS 7
POWER SUPPLY 8
FUNCTION MODES 9
LEDS 10
RS232 12
RS485 13
CAN 14
ETHERNET 15
USE OF SW67324 16
NEW CONFIGURATION 17
LOAD CONFIGURATION 18
SAVE CONFIGURATION 19
UPDATE DEVICE 20
SOFTWARE PREFERENCES 23
CONFIGURATION SETTING 24
DOWNLOAD DATA 32
DATE & TIME SETTINGS 34
WEBSERVER INTERFACE 35
MECHANICAL DIMENSIONS 40
ORDERING INFORMATIONS 41
ACCESSORIES 42
DISCLAIMER 43
OTHER REGULATIONS AND STANDARDS 43
WARRANTIES AND TECHNICAL SUPPORT 44
RETURN POLICY 44
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that you
need to check that the following document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code”
that appears at the top right-hand corner of each page of this document
With this “Document Code” go to web page www adfweb com/download/ and
search for the corresponding code on the page Click on the proper “Document
Code” and download the updates
REVISION LIST:
Revision Date Author
Chapter
Description
1 002 07/02/2013
Nt All Added new chapters
1 003 20/05/2013
Fl All Add USB driver location
1 100 23/12/2015
Ff All Added Ethernet version
1 200 22/12/2017
Ff All Added CAN version
WARNING:
ADFweb com reserves the right to change information in this manual about
our product without warning
ADFweb com is not responsible for any error this manual may contain
TRADEMARKS:
All trademarks mentioned in this document belong to their respective owners

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 3 of 44
SECURITY ALERT:
G
ENERAL
I
NFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual When using the device, legal and
safety regulation are required for each individual application The same applies also when using accessories
I
NTENDED
U
SE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i e
independent limit switches, mechanical interlocks, etc )
Q
UALIFIED
P
ERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and
who have appropriate qualifications for their job
R
ESIDUAL
R
ISKS
The device is state-of-the-art and is safe The instruments can represent a potential hazard if they are inappropriately installed and
operated by untrained personnel These instructions refer to residual risks with the following symbol:
This symbol indicates that non-observance of the safety instructions is a danger for people that could lead to serious injury or
death and / or the possibility of damage
CE
CONFORMITY
The declaration is made by our company You can send an email to support@adfweb com or give us a call if you need it

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 4 of 44
CONNECTION SCHEME:
Figure 1a: Connection scheme for HD67324-B2-E-232-xGB

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 5 of 44
Figure 1b: Connection scheme for HD67324-B2-E-485-xGB

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 6 of 44
Figure 1b: Connection scheme for HD67324-B2-E-CAN-xGB

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 7 of 44
CHARACTERISTICS:
The HD67324 is a Modbus / CAN Datalogger
It has the following characteristics:
Electrical isolation for bus (RS232, RS485, CAN, Ethernet) connection;
Mountable on Rail DIN;
Power Supply 8…24V AC or 12…35V DC;
Temperature range -20°C to 70°C
CONFIGURATION:
You need Compositor SW67324 software on your PC in order to perform the following:
Define the parameter of Modbus line;
Set Time and Date;
Manage the Datalogger’s functions;
Update the device

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 8 of 44
POWER SUPPLY:
The devices can be powered at 8…24V AC and 12…35V DC For more details see the two tables below
VAC
VDC
Vmin Vmax Vmin Vmax
8V 24V 12V 35V
Consumption at 24V DC:
Device Consumption [W/VA]
HD67324-B2-E-232/485-xGB 3 5
HD67324-B2-E-CAN-xGB 3 5
HD67324-B2-E-232/485-xGB
HD67324-B2-E-CAN-xGB
Caution: Not reverse the polarity power

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 9 of 44
FUNCTION MODES:
HD67324-B2-E-xxx-xGB
The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’:
The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of
the device
The second, with ‘Dip1 of Dip-Switch A’ at “ON” position, is used for upload the Project
and/or Firmware
For the operations to follow for the updating, see ‘UPDATE DEVICE’ section
According to the functioning mode, the LEDs will have specifics functions, see ‘LEDS’ section

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
Modbus / CAN
-
Datalogger
Document code: MN67324_ENG Revision 1 200 Page 10 of 44
LEDS:
HD67324-B2-E-232-xGB
HD67324-B2-E-485-xGB
The device has got five LEDs that are used to give information of the functioning status
The various meanings of the LEDs are described in the table below
LED Normal Mode Boot Mode
1: Device State (green) Blinks slowly (~1Hz) Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
2: Ethernet communication
(yellow) Blinks when Ethernet request is received Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
3: Modbus communication
(yellow) Blinks when Modbus frame (RS232/RS485) is received Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
4: Modbus error (yellow)
ON: At least one Modbus request hasn’t a correct
response
OFF: No errors are present
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz : update in progress
5: Ethernet Link (green) ON: Ethernet cable connected
OFF: Ethernet cable disconnected
ON: Ethernet cable connected
OFF: Ethernet cable disconnected
Ce manuel convient aux modèles suivants
2
Table des matières