ADC HiGain HRE-819 Manuel utilisateur

HIGAIN OUTDOOR
DOUBLER ENCLOSURE
HRE-819 List 1 and List 2
Product Catalog: 150-819-100-03
CLEI: T1RHEE04 and T1RHEF04

150-819-100-03
ii June 19, 1998 HRE-819
Revision History of This Manual
Copyright
June 19, 1998
© 1998 ADC DSL Systems, Inc. All rights reserved.
Trademark Information
ADC is a registered trademark of ADC Telecommunications, Inc. HiGain is a registered trademark of ADC DSL Systems, Inc.
No right, license, or interest to such trademarks is granted hereunder, and you agree that no such right, license, or interest
shall be asserted by you with respect to such trademark.
Other product names mentioned in this document are used for identification purposes only and may be trademarks or
registered trademarks of their respective companies.
Disclaimer of Liability
Information contained in this document is company private toADC DSL Systems, Inc.,and shall not be modified, used, copied,
reproduced or disclosed in whole or in part without the written consent of ADC.
Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice.
In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further
disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of
liability applies to all products, publications and services during and after the warranty period.
Revision Release Date Revisions Made
01 February 2, 1998 Initial release
02 July 9, 1998 New illustrations, modifications to text.
03 October 14, 2002 ADC rebranding

150-819-100-03 Conventions Used in This Specification
HRE-819 June 19, 1998 iii
CONVENTIONS USED IN THIS SPECIFICATION
Two types of messages, identified by icons, may appear in the text:
INSPECTING SHIPMENT
Upon receipt of the equipment:
•Unpack each container and visually inspect it for signs of damage. If the equipment has been damaged in
transit, immediately report the extent of damage to the transportation company and to ADC. Order
replacement equipment, if necessary.
•Check the packing list to ensure complete and accurate shipment of each listed item. If the shipment is
incomplete or irregular, contact ADC as described in the Warranty. If you must store the equipment for a
prolonged period, store the equipment in its original container.
Notes contain information about special circumstances.
Cautions indicate the possibility of equipment damage or personal injury.

Inspecting Shipment 150-819-100-03
iv June 19, 1998 HRE-819

150-819-100-03 Table of Contents
HRE-819 List 1 and 2 July 9, 1998 v
TABLE OF CONTENTS
Overview ____________________________________________________________________________ 1
Enhanced Features .............................................................................................................................1
Standard Features...............................................................................................................................1
Description.........................................................................................................................................2
Mechanics............................................................................................................................2
Enclosure Base ....................................................................................................................4
Enclosure Housing...............................................................................................................4
Gel-filled Stub - HRE-819 List 1 Only ...............................................................................5
Air-filled Stub - HRE-819 List 2 Only................................................................................5
Pressurization.......................................................................................................................6
Air Bypass Valve ..................................................................................................6
Pressure-relief Valve and Air Stem.......................................................................7
Installation___________________________________________________________________________ 8
Unpacking..........................................................................................................................................8
Installing the Enclosure......................................................................................................................9
Manhole Installation............................................................................................................9
Aerial Installation ..............................................................................................................10
Splicing the Stub Cable....................................................................................................................11
Order Wire .......................................................................................................................................13
Through-Connecting........................................................................................................................14
Installing Doublers and Repeaters ...................................................................................................14
Wiring................................................................................................................................15
General Deployment Rules................................................................................................17
Maintenance ________________________________________________________________________ 18
Protector Extraction .........................................................................................................................18
Protector Installation........................................................................................................................18
Removing and Replacing Broken Cover Bolts................................................................................19
Replacement Parts............................................................................................................................20
Appendix A - Specifications____________________________________________________________ 21
Environment.....................................................................................................................................21
Dimensions.......................................................................................................................................21
Appendix B - Abbreviations ___________________________________________________________ 22
Appendix C - Product Support _________________________________________________________ 23
Bar Code Label and Configuration Number....................................................................................23

Table of Contents 150-819-100-03
vi July 9, 1998 HRE-819 List 1 and 2

150-819-100-03 Overview
HRE-819 List 1 and 2 July 9, 1998 1
OVERVIEW
This document describes the ADC®HiGain®Outdoor Mini and Micro Doubler Enclosures HRE-819 List 1 and
HRE-819List 2. The primaryapplication of the HRE-819 enclosure is to house HiGain Doubler units in a HiGain
repeaterless T1 transmission system. The HRE-819 is either a refurbished or originally manufactured AT&T
outdoor enclosure that has been enhanced to house up to:
•Twelve HiGain full-payload, T1 doublers (HDU-439 or HDU-409) or
•Twelve fractional T1 doublers (HDU-219) or
•Twelve 239 T1 repeaters or
•Twelve of any combination of these units
ENHANCED FEATURES
The HRE-819 has enhanced the standard AT&T 819 enclosure case in the following ways:
•Twelve, double-wide T1 239 slots for doublers or T1 repeaters
•Modified single 30-foot stub (54 pair, four group, quad S-screened)
•Enhanced thermal dissipation capabilities
STANDARD FEATURES
•Rack-mount or pole mount capability
•Primary surge suppression across all ports in every slot
•Support for pressure contactor alarm card
The cap, coil, filter, and type B protector functions are not supported.

Overview 150-819-100-03
2 July 9, 1998 HRE-819 List 1 and 2
DESCRIPTION
The HRE-819 List 1 is an AT&T-equivalent 819B1 or 819B2 outdoor enclosure with a gel-filled stub. The
HRE-819 List 2 is an AT&T-equivalent 819A1 or 819A2 outdoor enclosure with an air-filled stub. Figure 1
shows the HRE-819.
Figure 1. HRE-819 Outdoor Doubler Enclosure
Mechanics
The HRE-819 mechanics comply with standard AT&T 819 enclosure cases. The HRE-819 case
(Figure 2 on page 3) is composed of three basic subassemblies:
•An 81-type enclosure base
•A protected 89-type enclosure housing
•Removable access lids
The housing has two separate chambers. Each chamber has six double-wide slots and is accessed by a removable
lid. The HRE-819 family includes two types of lids and four types of bases. Table 1 on page 3 lists the type of
lids and bases and shows which ones are used for the HRE-819 List 1 and the HRE-819 List 2.

150-819-100-03 Overview
HRE-819 List 1 and 2 July 9, 1998 3
.
Figure 2. Enclosure Base and Housing
You can build the gel-filled List 1 unit with two regular-sized lids (a 2-inch deep, AT&T #842301483) or two
deep-dish lids (a 3.5-inch, AT&T 842301491). The List 1 requires an 81B1-1H base since it does not have an air
bypass valve.
You can build the air-filled List 2 unit only with the 2-inch deep lid and either the single-stub base (81A1-1H) or
a dual-stub base (81A1-1H or 81A2-2H). When you use a dual-stub base, the stub access opening adjacent to the
air cutoff valve is plugged.
Table 1. HRE-819 Mechanics
HRE-819 List Number
LID BASE
2-inch AT&T
#842301483 3.5-inch AT&T
#842301491 81B1-1H 81A1-1H 81A1-2H 81A2-2H
HRE-819 List 1, Gel X X X
HRE-819 List 2, Air X X X X
Housing
Housing base
Housing lids

Overview 150-819-100-03
4 July 9, 1998 HRE-819 List 1 and 2
Enclosure Base
The HRE-819 enclosure base is a molded plastic unit. The base contains the airbypass valve, pressure relief valve,
order wire port, stub cable, and mounting hardware.
In the event of damage to the housing, the housing can be detached from the base and replaced. This precludes the
need to blow the splice case and resplice a new unit stub into the main feeder cables. Whenever the base and
housing are separated and then reattached, torque the connecting bolts to 40 inch-pounds in the sequence shown
in Figure 3.
Figure 3. Sequence for Torquing the Base Connecting Bolts
Enclosure Housing
The enclosure housing (Figure 4 on page 5) is a molded plastic unit which has two separate chambers. Each
chamber has six double-wide slots and a slot for the maintenance pressure contactor plug. Each plug-in slot
contains connectors that accommodate both the plug-in unit and its associated protectors.
Seal the housing covers to the housing with a reusable gasket, which forms an airtight seal when the lid bolts are
properly torqued to 40 inch-pounds in the sequence inscribed on the lid (Figure 4 on page 5).
OW13
9
8
5
4
1
2
3
6
7
10
11
14
12
Stub
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels ADC Enceinte

ADC
ADC HIGAIN HRE-712 List 1 Manuel utilisateur

ADC
ADC OmniReach FDH 3000 Manuel utilisateur

ADC
ADC HRE-454 Manuel utilisateur

ADC
ADC TrueNet Rack Mount Fiber Enclosures RMG... Manuel utilisateur

ADC
ADC FRE-765 Manuel utilisateur

ADC
ADC Fiber Optic Wall Box FL1000 Series Instructions d'utilisation et de sécurité

ADC
ADC HiGain HRE-206 List 1 Instructions d'utilisation

ADC
ADC Below Ground HDSLx 8-Slot Repeater Housing Radiator... Manuel utilisateur

ADC
ADC WorldDSL EMS-830T Manuel utilisateur

ADC
ADC HiGain HRE-427 Manuel utilisateur