HARDWARE MANUAL
8:20 AM 04-10-00
QZ. ABC
1
DEF
23
GHI
4
JKL MNO
56
PR
7
TUV WXY
89
- P
0
IN OUT
CLEAR
ALPHA
ENTER
BACK
PACE
Data Collection Terminal

2
FCC Warning:
Note: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 1 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. The equipment
generates, uses, and can radiate radio frequency energy. If not installed and
used in accordance with the instruction manual, it may cause interference with
the radio and television reception in a residential area, in which case the user
will be required to correct the interference at his or her own expense.
If this equipment causes interference, try to correct the problem by:
Reorienting the receiving antenna.
Relocating the terminal with respect to the receiver with which it inter-
feres.
Plugging the terminal into a different AC outlet, and putting the terminal
and receiver on different branch circuits.
FCC Compliance: (on hardware equipped with modem)
This equipment complies with Part 68 of FCC Rules. Upon request, furnish the
following information to the telephone company (telco).
Manufacturer: Acroprint Time Recorder Co., Inc.
Model: Badger II Terminal
FCC registration number: 4G3USA-21602-DT-E
Ringer equivalence: 0.7B
USOC modular telephone jack: R-J11
Lithium Battery Caution:
This circuit board on this terminal is populated with a lithium battery to protect
data or programs stored in the Random Access Memory (RAM). Do not, under
any circumstances, attempt to replace the lithium battery in the terminal.
Failure to comply may invalidate your warranty. Battery replacement should be
done by qualified personnel wearing the proper eye protection.
CAUTION: Danger of explosion if battery is incorrectly replaced. Replace
only with the same or equivalent type recommended by the manufacturer.
Discard used batteries according to the manufacturers instruction.
Declaration Of Conformity According To EMC Directive 89/336/EEC
We declare under our sole responsibility that the magnetic stripe and/or bar
code reading and/or data recording equipment Badger II 01-0119-000/003/
00 /007 to which this declaration relates are in conformity with the following
standards: EN 022:1987, EN 0082-1, IEC 801-2, IEC 801-3, IEC 801-4,
IEC 801- . I, the undersigned, hereby declare that the equipment specified
above conforms to the above directive and standards.
Raleigh, North Carolina USA
October 7, 2002 W. Glenn Robbins
All Rights Reserved. © COPYRIGHT 1996
Acroprint Time Recorder Company

3
Table of Contents
1. Introduction ................................................................. 4
Basic hardware and variations ................................................ 4
General specifications............................................................. 5
2. Setup ............................................................................ 6
Site requirements .................................................................... 6
Unpackin and inspection ...................................................... 6
Mountin ................................................................................ 7
Power up ................................................................................. 7
3. Operator interface ....................................................... 8
ADCT Keypad ........................................................................ 8
DataLo Keypad ..................................................................... 8
Card reader ............................................................................. 9
4. Ports and connections ............................................. 10
Acroprint Data Collection Terminal setup instructions ........ 10
Ethernet port ......................................................................... 13
RS-232 Serial port ................................................................ 14
RS-232 Serial printer cables ................................................... 15
Local Area Network: RS-485 serial port .............................. 16
RS-485 Serial cables............................................................. 17
Modem port .......................................................................... 18
Modem cables ....................................................................... 19
Wand port ............................................................................. 20
Wand and Y-Cable ................................................................ 21
Parallel port........................................................................... 22
Parallel cable......................................................................... 23
5. Companion products ................................................ 24
Printer ................................................................................... 24
Readers ................................................................................. 24
Power Supplies ..................................................................... 25
External Relay Box, External Buzzer ................................... 25
Cables ................................................................................... 26
Cables, Converter, Bad e Racks........................................... 27
Table of Contents

4
Basic hardware and variations
The electronic hardware is a new, versatile platform desi ned for
use with various applications. This manual describes, in detail, the
electronic hardware aspects of the terminal you have purchased.
The details concernin terminal firmware and host software are
addressed in the manual which comes with the software.
All terminals are equipped with:
1) a ma netic stripe readin head
2) a 2 row x 20 character per row display
3) a 16-key full travel keypad
4) an RS-232 serial port
5) a wand port for optional bar code wand
6) two control lines for external relay control (door access,
and bell rin er are typical applications)
7) a 25-pin parallel port
The terminal is offered in different hardware variations. Listed
below are the variations by part number and description:
Part # Description
C - Programmable e-prom (DataLog)
01-0120-000 DataLog with LAN (RS-485)
01-0120-002 DataLog with Modem (no LAN)
01-0120-003 DataLog with LAN & Inte nal Visible Ba Code Reade
01-0120-004 DataLog with Modem & Inte nal Visible Ba Code Reade
01-0120-005 DataLog with LAN & Inte nal Inf a ed Ba Code Reade
01-0120-006 DataLog with Modem & Inte nal Inf a ed Ba Code Reade
01-0120-008 DataLog with Ethe net
01-0120-010 DataLog with Ethe net & Inte nal Visible Ba Code Reade
01-0120-012 DataLog with Ethe net & Inf a ed Ba Code Reade
Acrocomm e-prom (Acroprint Data Collection Terminal ADCT)
01-0147-000 Ac op int with LAN (RS-485)
01-0147-002 Ac op int with Modem (no LAN)
01-0147-003 Ac op int with LAN & Inte nal Visible Ba Code Reade
01-0147-004 Ac op int with Modem & Inte nal Visible Ba Code Reade
01-0147-005 Ac op int with LAN & Inte nal Inf a ed Ba Code Reade
01-0147-006 Ac op int with Modem & Inte nal Inf a ed Ba Code Reade
01-0147-008 Ac op int with Ethe net
01-0147-010 Ac op int with Ethe net & Inte nal Visible Ba Code Reade
01-0147-012 Ac op int with Ethe net & Inf a ed Ba Code Reade
Note: The part number of your unit can be found on the serial
number label on the back of the terminal.
1. Introduction
Introduction

5
General specifications
A. Enclosure: 8.7 in. (23 cm) wide x 6.1 in. (16 cm) tall x 2.3
in. (6 cm) deep. Clamshell construction of 0.125 in. (3
mm) thick Polycarbonate/ABS injection molded flame
retardant plastic. Includes reversible mountin bracket and
access door which protects I/O ports.
B. Multilayer main lo ic board with internal round and power
planes.
C. Z-180 Microprocessor.
D. Up to 512 Kbyte confi urable memory. Most common
confi uration is 64K ROM and 128K RAM.
E. Lithium battery backed RAM.
F. Real Time Clock Chip on-board.
G. Ma netic card reader: Track 2 ABA recordin head for readin
standard Credit Card format throu h the slot.
. Display: 2 lines with 20 characters on each line. ADCT is backlit.
I. Keypad: Full travel keys with elastomeric contact pad, 4 rows x
4 columns.
J. Serial Port: RS-232 usin 6 position (4 contact) RJ-11 modular
connection.
K. Serial Port: RS-485 (Local Area Network) usin RJ-11 modular
connection.
L. Parallel port: 25-pin DB connection.
M. Internal Modem: Bell 212A (1200bps) and 103 (300bps) ,
CCITT V.22 bis (2400 bps) and V.22 (1200 bps), asynchro-
nous, licensed for use over public telephone lines.
N. Internal Multi-Frequency Piezo Electric Buzzer.
O. Internal Bar Code Reader: Visible or Infrared Bar Code
readin throu h the slot.
P. Control lines: Two pins of the 6-pin circular DIN connector
can be used with external relay box to control devices such
as door locks and bells.
Q. External Bar Code port: 6-pin DIN connection for external
Bar Code Wand or Bar Code Gun.
R. Power: Wall mount transformer, 9 Volts AC/DC 800 mA
minimum or 10 Volts AC/DC 700 mA minimum, with
female secondary plu size 2.1 x 5.5 mm.
Introduction

6
2. Setup
Site requirements
The terminal can be installed in any normal office or controlled
factory environment. However, do not use the terminal under the
followin conditions:
extremely hi h or low temperature
[operating temperature range: 0° to 50° C (32° to 122° F ]
[storage temperature range: -20° to 60° C (-4° to 140° F ]
extremely hi h or low humidity
[operating humidity range : 0 to 90% RH non-condensing]
areas of hi h dust concentration
areas with chemical fume concentration
areas with extreme vibration or when placed on an unstable or
unlevel surface
Unpacking and inspection
Havin opened the shippin carton, carefully remove the con-
tents. Inspect the terminal and accessories for dama e. Report
dama e or shorta es to the company from which the unit was
purchased. Complete the re istration card with all important
information.
(1) Terminal
(1) Power Supply
(4) Mounting Screws (1) Manual
8:20 AM 04-10-00
QZ. ABC
1
DEF
23
GHI
4
JKL MNO
56
PR
7
TUV WXY
89
- P
0
IN OUT
CLEAR
ALPHA
ENTER
BACK
PACE
Setup
HARDWARE MANUAL
8:20 AM 04-10-00
QZ.ABC
1
DEF
23
GHI
4
JKLMNO
56
PR
7
TUVWXY
89
-P
0
IN OUT
CLEAR
ALPHA
ENTER
BACK
PACE
Data Collection Terminal

7
Mounting
Unscrew the access door. With the door off, the main unit can be
slid upward and removed from the mountin bracket. The bracket
can be used for wall mountin , or it can be reversed to tilt the unit
on a desktop.
Power up
Plu in the power cord comin from the wall mount transformer into
the terminal. Reattach the access door and secure the unit to the
reversible bracket. Replace screw on the access door.
NOTE: Other connections are made in the same fashion. Notice
the channels in the bracket available for cable routin . Also, the
bracket has throu h-holes for further securin of cables usin
ties.
Setup

8
3. Operator interface
ADCT Keypad
The terminal has 16 keys for enterin alphabetical and numeric
data as illustrated below.
QZ.
1
ABC
2
DEF
3
GHI
4JKL
5
MNO
6
PRS
7
TUV
8
WXY
9
-SP
0
CLEAR
ENTER
BACK
SPACE
ALPHA
IN OUT
Operator interface
DataLog Keypad
The terminal has 16 keys for enterin data as illustrated below.
123
456
789
0
CLEAR
MENU
MENU
ENTER

9
Optionally, the terminal can also have an internal bar code reader.
The card is swiped throu h in the same fashion, but the Bar Code
should be on the left side of the card when swiped.
NOTE: For throu h-the-slot readin , Bar Code should be located
on card as shown.
Magnetic stripe -
right side
Bar Code - left side
1.00" Min.
0.25" Nominal
Operator interface
Card reader
The terminal has an internal ma netic stripe card reader. The
ma netic stripe on the card should be on the ri ht side when the
card is swiped as shown below.

10
4. Ports and connections
Acroprint Data Collection Terminal setup instructions
Configuring procedure for entering the DATE & TIME:
Swipe the Confi uration Bad e 000000000
(This bad e is provided with each terminal)
Select option 1 for DATE <Press ENTER>
Select the Day, Month, Year DDMMYYYY <Press ENTER>
Select the Time HH:MM <Press ENTER>
(Time is entered in military time, 2:00 pm = 14:00)
Configuring procedure for selecting PORTS:
Swipe the Confi uration Bad e 000000000
(This bad e is provided with each terminal.)
Select option 2 for Ports <press ENTER>
Select option 0 for RS232 <press ENTER>
Select the baud rate 0 for 1200, 1 for 2400, 2 for 4800, 3 for 9600
and 4 for 19,200 baud. <press ENTER>
(For modem terminal only)
Select option 1 for Modem <press ENTER>
Select the Modem baud rate 0 for 1200 and 1 for 2400 baud
<press ENTER>
Select the Answer Window HHMMHHMM for startin and
endin times <press ENTER> (time is in military format, Example:
Clock will not answer durin business hours and only answer between
the hours of 8:00 pm and 6:00 am, then select 20000600.)
Ports and connections
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels Acroprint Contrôleurs d'accès IP