Acrel ASL2 Series Manuel utilisateur

542
ASL2XX Series switch drives
Installation of IFU V1.2
Jiangsu Acrel Electric MFG.Co., Ltd.

Declare
All rights reserved, without the written permission of the
Company, any paragraph or chapter in this manual shall not be
copied, copied or disseminated in any form, otherwise all
consequences shall be borne by the violators.
The Company reserves all legal rights.
The Company reserves the right to modifications to the product specifications
described in this manual without notice. Before ordering, please consult the local agent
for the new specifications of this product

catalogue
1. Overview ......................................................................1
2. Product model number ..........................................................1
3. Main technical parameters .....................................................1
4. Installation and wiring .......................................................2
4.1 Profile and installation dimensions ...................................... 2
4.2 Electrical wiring diagram ................................................ 4
5. Use the operation guide .......................................................7
5.1 Definlight definition .................................................... 7
5.1.1 Light light of main module ..........................................7
5.1.2 From the module indicator light .....................................8
5.2 Key-press operation ...................................................... 8
5.2.1 Description of the main module keys .................................8
5.2.2 Description of the keys from the module .............................9
5.3 liquid crystal display .................................................. 10
5.3.2 Information query ..................................................11
5.3.3 Time setting .......................................................12
5.3.4 Timing schedule setting ............................................12
5.3.5 Timed plan view ....................................................13
5.3.6 DI / DO linkage ....................................................15
5.3.7 RS485 communication settings .......................................16
5.3.8 Other Parameters and information ...................................17
6. Functional application .......................................................20
6.1 The heartbeat message ................................................... 20
6.2 General functions ....................................................... 20
6.3 Scene function .......................................................... 20
6.4 Time function ........................................................... 20
7. The Newsletter Guide .........................................................20
7.1 Interface Overview ...................................................... 20
7.1.1 Transmission mode ..................................................20
7.1.2, information frame format ..........................................20
7.2 Introduction to the function code ....................................... 21
7.2.1 Function code 03H: read register ...................................21
7.2.2 Function code 10H: Write the register ..............................22
7.3 Drive parameter address table ........................................... 22
7.3.1 Drive real-time status address table ...............................22
7.3.2 Parameter setting address table ....................................25

7.3.3 Timing address table ...............................................28
7.3.4 Event record address table .........................................33
8. Analysis and troubleshooting of common faults ................................36
9. Notes ........................................................................36

Page 11
1. summary
ASL2XX Series switch driver (hereinafter referred to as module) is the control module of Ankory
ALIBUS intelligent lighting control system. The module is connected with other devices (such as
smart panels, sensors, etc.) to form a complete set of lighting control system, realizing the
intelligent management of large public construction and building lighting systems.
As a driver module, the module directly controls the on-off of the load power supply and realizes
a variety of control functions, such as load switching, event recording, timing switch, delay light
off, scene control, etc.
2. product model
ASL □ - S □ / 16
Table 1: Product Specification Table
product model
functional description
ASL220Z-Sx/16
RS485 communication, fire control linkage 2DI / 2 DO, 30 scheduled
tasks (including astronomical clock), 24 scheduled tasks, LCD
display, 600 switch records, 10 switch records, 12 DIDO records,
split and closed channels (over zero trigger), closing times record,
closing time accumulation, voltage, current measurement, electric
energy statistics
ASL220-Sx/16
RS485 communication, fire control linkage 2DI / 2 DO, 30 scheduled
tasks (including astronomical clock), 24 scheduled tasks, LCD
display, 600 switch records, 10 switch records, 12 DIDO records,
split and closing channels, closing times records, closing time
accumulation
ASL210-Sx/16
RS485 communication, fire linkage 1DI / 1 DO, split and split channel
3. Main technical parameters
Table 2: Technical parameters table
Module type: S represents the
Number of loops: 4 / 8 / 12 / 16 / 20 / 24
Anbranch intelligent lighting
Rated current: 16A
Module version: 210 base edition, 220

2
project
metric
A SL220Z-Sx/16
ASL220-Sx/16
ASL210-Sx/16
Power
power
consump
tion
rated
voltage
AC220V±10%
power
dissipa
tion
Normal operating condition: 5W
Normal operating
condition: 3W
Remote control
output
Relay with dial rod, rated current 16A
on-off input
Two passive dry contact input
There is no source dry
contact input
Switch output
Two passive often open contact, contact capacity
AC 220V / 1A, DC 30V / 1A
No active often open
contact, contact
capacity AC 220V / 1A, DC
30V / 1A
communication
ALIBUS Agreement, and the Modbus-RTU protocol
way to install
35mm guide rail type installation
service environment
Operating temperature: -10℃ - - + 55℃; Relative humidity: 95% uncovered
Storage temperature
range
-20℃-+70℃
Local operation
interface
Key + LCD monochrome LCD display
Key + dial code switch
certainty of
measurement
Voltage, current level
1
Power level 2
/
Zero trigger
Support the relay
over-zero trigger
/
4. Installation and wiring
4.1 Profile and installation dimensions (mm)
A SL220Z-Sx / 16 Switch Drive (same as ASL220-Sx / 16 switch drive)

3
Figure 1 A SL220Z-Sx / 16 switch drive profile and installation dimensions
Table 3 ASL220Z-Sx / 16 Switswitch Model Description
product model
Number of
loops
Module width
(B)
modulus
ASL220Z-S4/16
4
144mm
8 Mod
ASL220Z-S8/16
8
216mm
12 Mod
ASL220Z-S12/16
12
288mm
16 Mod
ASL220Z-S16/16
16
360mm
20 Module
ASL220Z-S20/16
20
432mm
24 Mod
ASL220Z-S24/16
24
504mm
28 Mod
Installation tip: This module is suitable for 35mm guide rail installation, installation only need
to put the module into the track.
ASL210-Sx / 16 Switch drive
B

4
Figure 2 ASL210-Sx / 16
Table 4 ASL210-Sx / 16
product model
Number of
Module width
modulus
ASL210-S4/16
4
108mm
6 Mod
ASL210-S8/16
8
180mm
10 Module
ASL210-S12/16
12
252mm
14 Mod
ASL210-S16/16
16
324mm
18 Mod
ASL210-S20/16
20
396mm
22 Mod
ASL210-S24/16
24
468mm
26 Mod
Installation tip: This module is suitable for 35mm guide rail installation, installation only need
to put the module into the track.
4.2 Electrical wiring diagram
ASL220Z-Sx / 16 Switch Drive (same as ASL220-Sx / 16 switch drive)

5
Figure 3 ASL220Z-wiring diagram of Sx / 16
Figure 3 shows the wiring diagram of the 4-way switch driver. In practical use, the
4,8,12,16,20,24 switch driver wiring is similar, which are not listed here.
1Lighting circuit switch control port;
2Relay manual operation hole;
Note: The number of the switch loop is sorted from left to right;
3Programming buttons;
4working station indicator;
5Power supply input terminal;
6Display screen, operation / communication indicator, DI / DO indicator;
7Operation keys: MENU menu key, left key, right key, return and turn page;
8ALIBUS Communication interface;
9485 Communication and DI / DO input terminals;

6
10 Voltage measuring terminal; (ASL220Z series switch drivers)
ASL210-Sx / 16 Switch drive
Figure 4 ASL210-Sx / 16
Figure 4 shows the wiring diagram of the 4-way switch driver. In practical use, the
4,8,12,16,20,24 switch driver wiring is similar, and they are not listed here.
1Lighting circuit switch control port;
2Relay manual operation hole;
Note: The number of the switch loop is sorted from left to right;
3Programming buttons;
Ce manuel convient aux modèles suivants
3
Table des matières
Manuels Entraînement CC populaires d'autres marques

Vincent Associates
Vincent Associates UNIBLITZ ED12DSS Manuel utilisateur

EKSMA OPTICS
EKSMA OPTICS DQ-100-4 Manuel de la liste des pièces

Chamberlain Garog
Chamberlain Garog D Series Manuel utilisateur

Parker
Parker PDS Series Manuel utilisateur

Festo
Festo DGC G Series Guide de configuration

Binks
Binks QS-5012-1-CE Manuel utilisateur