■TROUBLESHOOTING
◆The solution for digital display code problem:
There are total 2 sensors,one is near Evaporator which can be only seen when open wind channel plate
in freezer chamber,this is evaporator temperature sensor. The other is in Freezer Chamber room,
touching the temperature, which is temperature control capillary tube(the temperature sensor inside the
cabinet).
Considering the Sensor connecting or cutting problem, in order to check the problem easier, we get the
display error to distinguish the problem when we design the product.
When the digital display window shows ‘E1’ that means the circuit of the temperature sensor inside the
cabinet is open circuit or short circuit,
When the digital display window shows ‘E2’ that means the circuit of the defrost sensor(evaporator
temperature sensor) is open circuit or short circuit.
The digital display window shows ‘E3’ that means the temperature sensor inside the cabinet and the
defrost sensor occur both fault.
Both sensors are connected on the main board which realize the connection. So when display shows
Erro problem, we need to check the sensor itself have problem or not,meanwhile, need to check the
connect well or not between the sensors and main board.
Detail method show below:
The testing method of sensor:
Using the multimeter with the ohm switch to measure the resistor of sensor, normally at surrounding 25℃
the resistor should be about 2kohm and every with the temperature decreases 1℃the corresponding
resistor value would increase about 45ohm.If the measured value is not within the normal scope, the
sensor is bad and needs to repair or change.
The solution for “E1”problem
Open the door and put out the drawer