Ace UDD-24-48-HC Manuel utilisateur

USER MANUAL
Commercial Kegerator
(Beer Dispenser)
Models: UDD-24-48-HC / UDD-24-60-HC / UDD-24-72-HC
PLEASE READ THE MANUAL THOROUGHLY PRIOR TO
EQUIPMENT INSTALLATION, OPERATION AND MAINTENANCE!

Congratulations!
You have selected one of the finest commercial refrigeration
units made. It is manufactured under strict quality controls with
only the best quality materials available. When properly
maintained your cooler will give you many years of trouble free
service. !

TABLE OF CONTENTS
SAFETY PRECAUTIONS
UNIT INSTALLATION
BEER DISPENSING INSTALLATION & MAINTENANCE
OPERATION
STAINLESS STEEL CARE AND CLEANING
UNIT MAINTENANCE & CONDENSER CLEANING
TROUBLE SHOOTING

SAFETY PRECAUTIONS
Important Safety Note:
It is strongly recommended that any service, maintenance or
repair to be performed by a licensed & authorized technician.
Basic safety precautions should be followed when using commercial
refrigeration equipments or any other electrical appliances, such as:
Unplug the equipment from the electrical outlet before cleaning or
performing any repairs or maintenance.
Always use protective gloves when cleaning the exterior or interior or
touching any interior surfaces or components of the equipment.
Do not touch the cold surfaces inside the refrigerator cooling
compartment with bare damp or wet hands, the skin may stick to the
extremely cold surfaces and cause harm or skin injury.
Do not allow children to play around the equipment, climb over, stand
on or pull the shelves, to avoid any serious injury.
Do not store or use gasoline or any other flammable liquids / vapors
in the vicinity of this equipment or any other appliances.

UNIT INSTALLATION
Important Installation Note:
It is highly recommend to have a licensed refrigeration
technician (or a licensed electrician) properly install your Commercial
Refrigeration Equipment and use the unit as it is intended for, in a
commercial location and for commercial purpose only.
Prior to installation, all the packing materials (such as cardboards,
protective foams, plastic covers and tapes) should be removed.
Inspect the unit for any concealed damages prior to installation and
contact the manufacturer or the authorized dealer in case of any
interior or exterior damages.
To insure proper operations and performance the unit should be
installed on a flat and level floor. Use a leveling device to make sure
the unit is level front to back and left to right, including interior floor.
Kegerator unit should be placed and installed in a well-ventilated area
with at least 2 inches of space between the surrounding walls and the
unit exterior walls, to insure proper air circulation.
To avoid a decrease in cooling efficiency, the unit should be placed
far from any heating source and away from direct sunlight.
Under extreme heat conditions, over 100°F (38°C), placing an
external blower fan near the unit, for additional air circulation through
compressor compartment, is recommended.
Install the unit indoor and in a dry (low humidity) place to prevent rust
forming on the metal parts and the exterior panels, high humidity also
cause damage to electrical components and wiring.!

BEER DISPENSING INSTALLATION & MAINTENANCE



Electrical Safety and Power Cord Connection:
Important Safety Note:
Do not under any circumstances cut or remove the grounding
prong from the power cord. For safety this appliance must be
properly grounded at all times.
The power cord of the Kegerator unit is equipped with a grounding
wire and plugs to standard grounded wall outlet to minimize the
possibility of electric shock hazard.
If the outlet is a standard 2-prong outlet, it must be replaced with the
properly grounded wall outlet. NEVER USE AN ADAPTER PLUG!
Have the wall outlet and circuit checked by a qualified electrician to
make sure the outlet is properly grounded. Check the outlet voltage
with a voltmeter. If the results are anything less than 100% of the
required voltage for operation, it must be corrected immediately.
WARNING: Compressor warranties are voided if the compressor
fails due to low voltage or power surge.
DO NOT USE AN EXTENSION CORD. Using any kind of extension
cord to connect the unit will void the warranty. The unit must be close
enough to a wall outlet, so use of an extension cord not needed.
The unit should always be plugged into its own dedicated circuit with a
voltage rating that matches the compressor rating. This provides the
best performance and also prevents overheating power cord which
could become a fire hazard from overheated wires.
Never unplug the unit by pulling the power cord. Always grip the plug
firmly and pull it out straight from the outlet.
Repair or replace immediately all power cords that have become fried,
melted or otherwise damaged. Do not use a power cord that has
cracks or abrasion damage along its length or at either of its ends.
When removing the unit away from the wall be careful not to run over
or damage the power cord.
NOTE: Wiring Diagram label is placed on the interior side wall, additional
copies will be provided by the manufacturer upon request.!

OPERATION INSTRUCTIONS
Important Operation Note:
Anytime the unit is unplugged or the power is turned off, allow at least five
(5) minutes before re-plugging or turning the power on.
Before using or placing any products inside the unit, it is
recommenced to let it operate for 1 to 2 days with the unit doors
closed, to insure the temperature reaches and stays within the set
points. This will also insure the unit is operating properly and there
are no shipping damages or issues with the cooling system.
As a reminder, the manufacturer warranty does not cover product
loss.
Be careful NOT to block the interior fans (air ducts) located on the
ceiling or the air-flow through interior back wall.
Blocking the air flow may cause decrease in performance & uneven
temperature through the unit interior.
For the best performance, maintain at least 4 inches of clearance
between the contents and the interior air duct / fans.
Use the shelves that comes with the unit and fit in correctly.
Do not leave the unit door open for a long period of time, close the
door immediately after each use, for optimum operation.
Interior Light Switch:
The light switch is located on the left side of side grill.
Digital Temperature controller:
The controller is programmed by the factory and set to the
recommended settings for the Kegerator unit and no adjustments are
needed.
Default lowest point temperature is set at “34" degrees with“7”
degrees of temperature differentials.
Changing the factory settings could lead to unit malfunction and
performance problems.
Contact the manufacturer or authorized dealer if there is an issue with
the temperature and the unit is not performing properly.!
Ce manuel convient aux modèles suivants
2
Table des matières
Manuels Tireuse à bière populaires d'autres marques

Nostalgia Electrics
Nostalgia Electrics KEG9000DTSS Manuel utilisateur

Nostalgia Electrics
Nostalgia Electrics KRS2100 SERIES Manuel utilisateur

NPC
NPC ReverseTap Manuel utilisateur

AMD DIrect
AMD DIrect SSRFR-24DK Manuel utilisateur

PolyKeg
PolyKeg PRO Manuel utilisateur

PolyKeg
PolyKeg PRO one-way keg Manuel utilisateur

KegLand
KegLand Fermzilla Manuel utilisateur

EdgeStar
EdgeStar KC3000 Manuel utilisateur

Nostalgia Electrics
Nostalgia Electrics Kegorator KRS-2150 Manuel utilisateur

Nostalgia Electrics
Nostalgia Electrics KEGORATOR KRS-2000 SERIES Manuel utilisateur

NPC
NPC ReverseTap RD-B1 Manuel utilisateur

KegLand
KegLand Benchy Carbon KL18210 Manuel utilisateur