AAVARA PB9000W Manuel utilisateur

2
Table of Contents
I. PB9000 models: ............................................................................................................................................. 3
II. Ethernet Switch Setting ................................................................................................................................. 3
III. PB9000 Hardware Installation...................................................................................................................... 3
IV. Integrate with 3rd Party Controller ............................................................................................................... 4
V. User Scenario - Use IR Remote/Dip Switch to Switch Video Channel ......................................................... 5
VI. IP Setting, Web Configuration & Control...................................................................................................... 6
VI.A. To Know IP address of Aavara HDMI Over IP Sender and Receiver.................................................. 6
VI.B. Launch AV Master Control Web page ................................................................................................. 6
VI.C. Change IP address of Sender and Receiver ...................................................................................... 7
VII. Aavara AV Master Web Interface ............................................................................................................... 8
VII.A. User Login .......................................................................................................................................... 8
VII.B. Setup within AV Master Web Interface ............................................................................................. 10
VII.C. Setup & Backup by CSV files........................................................................................................... 12
VII.D. Device IR Command Learning ......................................................................................................... 19
VII.E. Multicast ........................................................................................................................................... 20
VII.F. Matrix................................................................................................................................................. 20
VII.G. Multicast Group ................................................................................................................................ 21
VII.H. Click Apply ButtonVideoWall Setup.................................................................................................. 22
VII.I. VideoWall ........................................................................................................................................... 23
VII.J. Control............................................................................................................................................... 24
VII.K. EDID Manager (Only Available on Sender)...................................................................................... 25
VII.L. User Management ............................................................................................................................ 27
Information in this document is subject to change without notice.
© 2021 Aavara Innovation Corp. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Aavara Innovation Corp. is strictly
forbidden.
Trademarks used in this text: Aavara, the Aavara logo and Aavara AV Master are trademarks of Aavara Innovation
Corp.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and
names or their products. Aavara Innovation Corp. disclaims any proprietary interest in trademarks and trade names
other than its own.

3
I.PB9000 models:
Model
PB9000-SE+
PB9000W-SE
PB9000HD-SE
PB9000-R
Sender/Receiver
4K Sender
EU Wall-Plate
Sender
1080p Sender
Receiver
Max. Video Format
4K60Hz 4:2:0 Input
4K60Hz 4:2:0 Input
1080p60Hz 4:4:4
Input
4K30Hz 4:4:4 Output
Max. Audio Format
7.2 ch LPCM/Dolby ATMOS/DTS X
Video Connector
HDMI/VGA Input,
HDMI Loop out
HDMI/VGA Input
HDMI/VGA Input,
VGA Loop out
HDMI/VGA Output
Audio Connector
3.6mm Line In/Line
Out, S/PDIF Optical
Out
3.6mm Line In/Line
Out
3.6mm Line In/Line
Out
3.6mm Line
In/Speaker Out
RS232 Connector
DB15 x 1
DB15 x 1
DB15 x 1
DB15 x 1
IR Connector
IR Emitter Jack x 1
IR Receiver Jack x1
IR Emitter Jack x 1
IR Receiver Jack x1
IR Emitter Jack x 1
IR Receiver Jack x1
IR Emitter Jack x 1
IR Receiver Jack x1
USB Connector
USB Type B x 1
USB Type B x 1
USB Type B x 1
USB Type A x 4
II.Ethernet Switch Setting
1. Please select Layer 2/3 managed/smart switch to work with Aavara 4K Over IP.
2. Enable IGMPSnooping (Version 2) and have all senders/receivers in same VLAN group.
3. Enable JumobFrame (at least 8Kb) on all ethernet switches.
4. Enable IGMP Querier on major switch and disable Fast Leave on all switches, if multiple ethernet
switches installed.
If be sure network bandwidth between switches enough for video network, can use Fiber connection
or set 802.3ad Port Trunking/Link Aggregation to increase bandwidth between switches.
5. If Ethernet switch is also use for other service like PC network or Voice Over IP:
- Set different VLAN groups to divide different network service.
- For RJ45 ports or Fiber ports used for other services, set IGMP Blocked (HP switch) or Multicast
Forward Forbidden (Cisco switch), to avoid video streaming data affect.
6. Be sure to save the above setting before rebooting ethernet switch.
III.PB9000 Hardware Installation
1. Connect all Senders and Receivers to Gigabit Switch by Cat5e/6 cables and connect to video source
and TV/Display with HDMI cables.
2. [Optional] Connect IR emitter cables & IR Receiver cables to Sender/Receiver's IR Emitter/Receiver
Jack. IR emitter cable to IR emitter jack, IR receiver cable to IR receiver jack. And, point IR emitter
head of IR emitter cable to device IR receiver window, IR receiver head of IR receiver cable to IR
remote location and keep clear line of sight in between.
3. [optional] Connect RS232 cables between PC/controller to Senders, TV/Displays to Receivers.
4. [optional] Connect USB cables between PC/server to Senders and plug USB Keyboard/Mouse or other
USB devices to Receiver's USB port.
5. Plug-in DC power adapter to all Senders and Receivers. Units power on.
If PoE switch or PoE injector connected, then it’s not necessary to plug-in DC power adapter.
6. Power on all Video Sources and start to play video.

4
IV.Integrate with 3rd Party Controller
PB9000 supports following major 3rd party controller’s integration:
- Control 4, AMX, Crestron, Extron, RTI, Elan g!, Neets and more.
Aavara provides controller driver that allows 3rd part controller to control Aavara HDMI Over IP sender and
receiver by IP command directly.
Please check Aavara representative or your distributor for 3rd party driver and user instruction.

5
V.User Scenario - Use IR Remote/Dip Switch to Switch Video Channel
Use Aavara 16 channel IR remote (Optional accessory) /Dip Switch control to control PB9000-RE receiver
and switch video channel. User can also use a 3rd party universal IR remote to learn from Aavara IR remote’s
IR code and video source IR remote code for controlling both devices by one remote.
1. To config Sender Video Channel Dip switch, at front bezel, to a Unique video channel configuration
as following table. Recommend that start from video channel 1 then follow the sequence on every
sender. Reboot sender for new video channel setting and apply.
2. [Must] Plug-in IR receiver cable to PB9000-RE receiver IR receiver jack and toward to IR remote
location with clear line of sight.
3. [optional] Plug-in IR emitter cable to PB9000-SE sender IR Emitter jack and toward to video source
device IR receiver window if need IR control from TV/Display side.
4. Use IR remote of PB9000-RE or use 3rd party universal remote control (preconfigured with PB9000-
RE IR remote), toward IR receiver which connected to PB9000-RE IR.
Notice:
Maximum 16 video channels / sender / video sources allow at this scenario, number of TV/Displays is almost
unlimited.
IR remote control way is not compatible with Aavara AV Master Web Interface and 3rd party controller control,
please don’t mix use other control ways.
Once use Web interface Setup then Dip Switch setting will be ignored!

6
VI.IP Setting, Web Configuration & Control
VI.A. To Know IP address of Aavara HDMI Over IP Sender and Receiver
Aavara HDMI Over IP sender and receiver have factory default IP within 169.254.xxx.xxx C class range, and
netmask 255.255.0.0, IP address of each HDMI Over IP unit can be found by following way:
Unit IP Show On Screen OSD:
1. To set up a sender, connect to a receiver by Cat5e cables (can be with or without Ethernet switch in
between).
2. Receiver connected to a TV or Display with a HDMI cable.
3. Power on Sender, Receiver and TV/Display.
4. On right bottom of screen, it will show:
- Local IP Receiver IP address
- Remote IP Sender IP address
5. Then, please connect the sender to a PC/Notebook RJ45 port with a Cat5e cable, then power on.
6. To set PC/Notebook RJ45 port IP configuration as follow:
- IP address: 169.254.0.100 (or any IP within 169.254.xxx.xxx range)
- Netmask: 255.255.0.0
Or
Finding unit and IP in Bonjour Browser
Software Required:
1.Apple Bonjour SDK free download from Appple SDK web site, if you are using MS windows OS
PC/NB. Apple MacPro or MacBook which don't need it, had built-in OS X.
- can download from Apple developer web site
2.Bonjour Browser for easy find out all senders and receivers on network.
- Just google and download from Internet
1. To set PC/Notebook RJ45 port IP configuration as follow:
- IP address: 169.254.0.100 (or any IP within 169.254.xxx.xxx range)
- Netmask: 255.255.0.0
2. Setup all Cat5e cable connection between PC/Notebook, sender, receiver and Ethernet switch, then
power on.
3. [optional] Install Apple Bonjour SDK on your MS Windows PC/Notebook.
4. Launch Bonjour Browser and check HTTP service section. All Aavara HDMI Over IP sender and
receiver can be found at following domain name:
- Sender Aavara-gateway0000.local 0000 represent video channel number
- Receiver Aavara-clientAAAAAAAAAAAA AAAAAAAAAAAA represent MAC address of
receiver
VI.B. Launch AV Master Control Web page
http://[unit ip]/cfg.html Unit configuration web page (needed only when you want to change unit IP)
http://[unit ip]/index.html Aavara AV Master /Control web page

7
VI.C. Change IP address of Sender and Receiver
Aavara HDMI Over IP sender and receiver got factory default IP within 169.254.xxx.xxx C class range, and
netmask 255.255.0.0. Recommend to set static IP to each box to know which one is which one on network.
IP address of each HDMI Over IP unit can be changed by following way:
1. Launch Web browser with following URL, the Unit Web page will show:
http://[unit ip]/cfg.html
3. Change IP Mode to Static
- IP Address: Please assign a IP with correct format. (Ensure all boxes’ IP are at same C or D class
range).
- Subnet Mask: 255.255.0.0 or base on proper ethernet network planning.
- Default Gateway: Only if need, please refer gateway setting on Router.
4. Click Apply Button to save new setting, but unit need to reboot to get new setting effect.
5. Click System Tab → Utilities → Click Reboot button, reboot.

8
VII. Aavara AV Master Web Interface
Aavara AV Master Web interface, built-in in every Aavara HDMI Over IP unit, is a one web page setup
and control entire HDMI Over IP AV Matrix and Video Wall. It will only need to configure and operate Aavara
AV Master Web Interface on One unit then that unit will become master control unit of entire system, usually
recommend that use first sender, then all rest of units just take order.
To Connect Aavara AV Master Web Interface via PC/Tablet connect to same ethernet Switch/Wifi AP with
following IP setting:
- IP address: any no conflict IP within same C or D class IP range with all senders and receivers.
- Netmask: 255.255.0.0 or value base network configuration that allow all unites can see each other.
Factory default IP range is 169.254.xxx.xxx netmask 255.255.0.0
Or, same static IP range had been set on boxes.
- Web browser: recommend Google Chrome, Firefox, Safari
Launch Web browser with following URL (domain name of sender at channel 0, default sender setting):
http://aavara-gateway0000.local
VII.A. User Login
Every time when launches web browser and Aavara AV Master Web page, it will ask user to login.
System Default Login name and Password (Can be revised or deleted later on at User Management
Tab) with Administrator authorization.
Login name: adm
Password: adm
After Login, on right top corner will show Login User info and Logout button.

9
User with Administrator authorization will see both AV Matrix/VideoWall/Control Operation and All
Setup functions.
User with Operator authorization will see AV Matrix/VideoWall Operation functions only.
Only User with Administrator Authorization allow to access unit configuration cfg.html
Access other units’ web page other than master control unit, will redirect web page/URL to master
control unit’s web page.
Once User Session expired, AV Master Web Interface will ask user to login again.

10
VII.B. Setup within AV Master Web Interface
Click on Setup Tab at first time of installation and then configuration will change accordingly, wait few
seconds, AV Master will scan and list all Senders and Receivers. Please configure all parameters for
Senders and Receivers based on your requirements of installation & operation, details as table below. All
settings will store in this Sender or Receiver only and later on operation will connect to this
Sender/Receiver's web page only.
If any USB or RS232 setting changed, the unit will need to reboot to get new setting take effect.
For Device Control Command code setup, need to be done by CSV file uploading way as next section
show.
Ce manuel convient aux modèles suivants
4
Table des matières
Autres manuels AAVARA Changer