Operation Guide 3M-30
The 3M-30 programmable communicating
thermostat operates via a high-quality, easy-
to-use touch screen. To program or adjust
your 3M-30, simply touch your nger rmly to
the screen. The screen will automatically light
up and you will hear a “beep.” The screen will
respond differently to different types of touches,
so you may want to experiment by touching it
different ways, nger, ngernail, etc. Do not use
a sharp or metallic device; it will scratch the
screen.
ENGLISH
Statement of use: 100% Compatible with all popular
residential HVAC systems; 24VAC single, two stage
conventional heating systems (gas/oil/electric), heat pumps,
single stage or with auxilliary heat (electric or fossil),
zoned forced air and zoned hot water (2 or 3 wire), millivolt
systems (with 24VAC adapter), one or two stage cooling,
and hybrid systems.
button
Save
Energy
button
Power Grid
status
indicator
top cover
Touch screen
Wire
terminals
Mode
Fan
MENU
button
PROG
Reset
button
HVAC
selections
switches
bottom
cover
DAY
F
LINK
RADIO
TA RGET TEMP
1
COOL
AUTO
PM
switch
switch
1005-002-001

PG 2
PG 2
Control Screens
Before you operate the 3M-30 please get familiar with these basic control screens. All the 3M-30
functions are accessed through these screens. HOME, MENU, PROGRAM and MANUAL . The
3M-30 touch screen technology allows you to select (by touching) an item and change it using the +/-
arrows or the time arrows.
HOME Screen
The HOME screen is displayed when the
unit is operating. Touching the HOME icon
on the screen will always return you to
this screen.
To set a Mode:
Set the mode switch on the side to the
desired mode COOL or HEAT.
FAN
MODE -
HEAT-OFF-COOL
DAY
PM
TARGET TEMP
HEAT
Thermostat
Mode
Time of day Current Room
Temperature Lock indicator
Target
Temperature
Day

PG 2
PG 2
PG 3
MENU Screen The MENU screen is the gateway to many functions or settings of the
3M-30. It is displayed when you press the MENU button. [See page 9 for details]
DIFF SWING
FILTER
PM
F
C
HVAC
SETUP
CALIBRATE
Set Day
Touch this area to set
the day of the week
Set Time
Touch this area to set
the time of day.
Left arrow goes back,
right arrow goes forward.
Calibration control
Use this to calibrate your
LCD display match to
another thermometer.
S
et
o
C -
o
F
Touch this to set
temperature display.
Lock Program
Touch for 5 sec
to lock or unlock.
Filter Timer
set
Chirp set
Touch this to turn the
audible chirp on or off.
T
emperature Swing set
Differential set
for 2nd Stage
HOME
Touch to
return to
HOME screen.
HVAC SETUP
Touch this to configure the
3M30 to work with your
HVAC system.

PG 4
PG 4
PROGRAM Screen The PROGRAM screen sets the 3M-30 control for your
home HVAC system. It is displayed when you press the PROG button. [See page 7 for details]
PROGRAM
MORN
AM
F
COPY
DAY
HEAT
Set Program Day
Touch this area to set the day of the
week you want to program TargetTemps for.
Set Time Slot
Touch this area to set the
Time Slot you want to program.
Set Program Time
Touch this area to set the
time of day you want each
time period to start.
Left arrow goes back,
right arrow goes forward.
[Touch and hold for fast set]
Copy
Touch this area to copy
current day’s program
to the next day.
Temp Up / Temp Down
Touch these to raise
and lower each Target Temp.
[Touch and hold for fast set]
Return HOME
When programming is complete
touch this to run your program and
return to the HOME screen.

PG 4
PG 4
PG 5
MANUAL Screen The Manual Screen control screen is where you can make
temporary changes to your 3M-30’s operation. Touch the main temperature display to use this
screen. [See page 12 for details]
HOLD
TEMPORARY
F
TEMP
HOLIDAY
HEAT
Target Temperature
Room Temperature
Return HOME
Temp Up / Temp Down arrows
Touch these to raise and lower
the manual override Target Temp.
HOLIDAY
Touch this to invoke a
single program that repeats day
after day until you turn it off.
HOLD Touch this area to operate the thermostat as
a manual thermostat. It will keep the temperature
you set until you change it or cancel HOLD.
Manual Override indicator
Shows TEMPORARY when
you have modified the Target.

PG 6
PG 6
Initial Settings
Press MENU to prepare the thermostat (from HOME screen).
Set day of the week -
Touch the Day of the week area to cycle through the days of the week to select the current day.
Set time of day -
Touch the Time of Day arrows to move the time selection forward or backward until
it displays the current time. Touch and hold for faster setting.
Set oF-oC display -
Touch the oF and it will toggle to oC.
Set audible chirp -
Touch the musical note icon to select the chirp
or no chirp.
Return HOME by touching the icon.
ForwardBackward

PG 6
PG 6
PG 7
Auto-run Program
The 3M-30 comes pre-programmed with an EPA approved program. This program is recommended
by the EPA for energy efciency. We strongly recommend that you Auto-Run this program for one
week, and see if it works for you. If it does not t your needs you can always input a custom program.
To run the EPA program, set the mode switch to HEAT or COOL.
Press the MENU button and use the arrows by the time display to set the time.
Touch the DAY area and advance it to select the present day.
Touch HOME. The unit is now running the program.t
All Days 70
o
F 62
o
F 70
o
6
2
o
F
MORN
6:00am
HEAT
DAY
8:00am
EVEN
6:00pm
NITE
10:00pm
All Days 78
o
F 85
o
F 78
o
F 82
o
F
MORN
6:00am
COOL
DAY
8:00am
EVEN
6:00pm
NITE
10:00pm
EPA
TO CHANGE THE PROGRAM:
Make sure the 3M-30 mode switch is set to either HEAT or COOL, then press the PROGRAM button.
This puts you at the PROGRAM screen [see page 4]. The programmed start time is diplayed in the
upper left. The TIME SLOT icon indicates the active TIME SLOT in the default program [MORN, DAY,
EVEN, NITE]. The programmed Target Temperature is shown on main display.
The HEAT program and the COOL programs are separate.

PG 8
PG 8
Select the day you want to program.
The day of the week starts at SU - Sunday and can be advanced to the day you want to program.
Touch the day of the week area to cycle through the days of the week to the desired day.
Select the time slot (period) you want to program (MORN,DAY, EVEN, NITE).
Touch the time slot area to cycle through to the desired period.
Select the desired start time of that time slot.
Touch the time arrows to select the desired period’s starting time. Hold arrow down for fast time
scrolling.
Select the desired target temperature for that time slot.
Touch the +/- arrows to select the desired period’s temperature.
To COPY one day’s programming to the next day, touch COPY DAY once. The information for the
current day will be copied to the next day which will appear on the screen. Holding down COPY for
over 3 seconds will copy to all 7 days.
Touch HOME to return to the Home screen.

PG 8
PG 8
PG 9
MENU Screen Functions
Press MENU to bring up MENU screen.
TIME of DAY
Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per
touch). Touch and hold the arrow for fast time set (15 minute jumps).
DAY of Week Touch DAY area to select present day.
SWING (HVAC cycling rate) This feature allows you to set the desired variance in temperature
between the 3M-30 setting and the room temperature required before the heating or cooling system
will turn on—from 0.5° to 2.0° F (.25° to 1° C). For example, if SWING is set to 2.0° F and the 3M-
30 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F.
Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then
runs and will shut off at the Target Temperature.
To set SWING:
Touch SWING.
Touch the left/right arrows to set the SWING from 0.5° to 2.0° F.
The HVAC will run more frequently at .5°F and less at 2°F. Default is 1°F.
Touch HOME to return to the MENU screen.

PG 10
PG 10
Chirp set - Touch this to turn the audible chirp sound on or off.
F
C
Set - Touch this to switch the temperature display scale from oF to oC .
FILTER - AIR FILTER ALERT - The 3M-30 can be programmed to remind you when the air lter
needs changing.
Touch FILTER. The display will show the usage to date.
Touch FILTER for over 3 seconds and the display will change to LIMIT.
Touch arrows to set desired usage limit before lter alert comes on home screen.
When this limit is reached, FILTER will be on home screen.
Limit may be set from 0 to 999 days; default is 90 days.
To reset, the usage back to 0, touch usage number; touching it again restores the displayed usage.
Touch HOME to return to the MENU screen.
LOCK (The 3M-30 has 2 lock modes)
Touch icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily
override the 3M-30 Target Temperature with the +/- buttons only. (1 bar)
For FULL lock : Touch the icon again for 5 seconds to go to full lock. No changes can be made. Full
lock shows (2 bars). Once locked, the 3M-30 will respond just to MODE and MENU.
Autres manuels pour 3M-30
2
Table des matières
Autres manuels 3M Thermostat
Manuels Thermostat populaires d'autres marques

EWELLY
EWELLY EW-181 Manuel utilisateur

Prolon
Prolon T1100 Instructions d'installation

Computherm
Computherm Q20 Manuel utilisateur

Heatmiser
Heatmiser neoStat Manuel utilisateur

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manuel utilisateur

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manuel utilisateur