Zener MSC-3 Manuel utilisateur

MSC-3
Instruction Manual
INVENTIVE TECHNOLOGY
DSP-II

IM00120
ZENER TECHNOLOGY AND QUALITY ASSURANCE
Since 1976 Zener Electric has supplied many thousands of drives to industry. These drives have
been installed into numerous applications resulting in a wealth of in house experience. The Zener
MSC-3 AC variable speed controller is the culmination of this experience, modern technology and
industrial application requirements. The Zener Quality Assurance program ensures that every MSC-3
manufactured has proven to operate correctly in the production test bay before dispatch.
SAFETY
Your MSC-3 must be applied, installed and operated in a safe manner. It is the responsibility of the user
to ensure compliance with all regulations and practices covering the installation and wiring of your MSC-
3. The instruction manual should be completely read and understood before attempting to connect or
operate the MSC-3. Only skilled personnel should install this equipment.
This equipment contains a number of components that are designated by their various manufacturers
as “not for use in life support appliances, devices or systems where malfunction of the components can
reasonably be expected to result in personal injury or death”. Customers using or selling Zener products
for use in such applications do so at their own risk and agree to indemnify Zener for any damage
resulting from improper use or sale.
THE CONTENTS OF THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE
Zener is a registered trademark of Zener Electric Pty Limited


A Zener Drive for Every Application
The ZENER MSC-3 series Variable Speed Drive is suitable for all types of loads, producing greater motor
torque over the full speed range with ZENER’s unique ‘Flux Plus’ control algorithm.
Variable Torque Loads
Typically Pumps and Fans
Constant Torque Loads
Typically Conveyors,
Machines
• Quiet Motor Operation (Audible frequency
adjustable from 2 to 16kHz)
• 110% full overload capacity from
0-200Hz
• Controlled ramp from 0.1 sec to 1min
• Able to start into a high inertia load
rotating at full speed without damage
• PID control for automatic process control
• Energy savings with speed reduction
• Soft Stop to reduce water hammer
problems
• Flux plus for torque maximisation
• 150% - 175% full overload capacity from
0-200Hz
• Automatic Boost and slip compensation
for uctuating loads
• Dynamic Braking for rapid deceleration of
high inertia loads (optional)
• Congurable Analog & Digital I/O
A Zener Drive for Different Environments
ZENER also offers a range of enclosure types to suit different environmental conditions, for improved life
expectancy and reliability. Ratings at 40ºC, 45ºC and a 50ºC rating are available.
IP30 ENCLOSED
Painted enclosure with IP30 rating for mounting within an
enclosure or Switch Board.
Up to 170Amps
IP 54 ENCLOSED
Painted enclosure with a dual compartment, self contained,
forced ventilated IP54 enclosure. All electronic components
are housed in a totally enclosed compartment separate from
the heatsink.
220-490Amp
IP66 ENCLOSED
Painted enclosure with a dual compartment, self-contained,
forced ventilated IP66 enclosure providing added protection
against the ingress of dust and water without the use of
air lters. All electronic components are housed in a totally
enclosed compartment separate from the heatsink and
ventilation fan compartment.
Up to 170Amps
IP66 STAINLESS STEEL
Stainless Steel 304 with a dual compartment, self-contained,
forced ventilated IP66 enclosure providing added protection
against the ingress of dust and water without the use of air
lters. All electronic components are housed in a totally en-
closed compartment separate from the heatsink and ventila-
tion fan compartment.
Up to 140Amps
IM00120
ii
IM00120

Zener MSC–3 Options
SUPPLY VOLTAGE
The ZENER MSC–3 is available to operate from the following types of power supplies;
Supply Voltage Supply Phase Tolerance Model
380 to 480Vac 3 Phase -15, , +10% MSC–3R
208 to 240Vac 3 Phase -15, , +10% MSC–3L
440 to 600Vac 3 Phase -15, , +10% MSC–3J
380 to 480Vac 1 Phase* -15, , +10% MSC–3R
208 to 240Vac 1 Phase* -15, , +10% MSC–3L
* Derating required for single phase operation. (See page 11)
DC BUS CHOKE
Provides a reduction of power line harmonics with the added
benet of reducing peak inrush currents, improved power factor
and enhanced protection against AC line transients.
Line Current without
a DC Bus Choke
Line with a DC
Bus Choke
REMOTE DISPLAY PANEL
Remote Display Kit which allows remote access to programming
menu and drive controls. An IP66 rating applies if tted correctly.
Available in 2m, 5m or 10m kits. Cable lengths greater than 10m may
required screened cable and/or additional power supply.
OPTION BOARDS
The ZENER MSC–3 provides 2 expansion slots located on the
control board to accept up to 2 option boards.
AQ08000 24vdc 20mA Power Supply Card
AQ08001 Extended Features; provides additional analogue
output, analogue input, thermistor input, 24VDC
20mA transducer loop power supply, 4 digital inputs
and a low voltage digital output.
Check with your authorised Zener Distributor for other options and
communications protocols.
IM00120
iii
IM00120
MSC-3 Instruction Manual

IM00120
iv
IM00120

IM00120
v
IM00120
MSC-3 Instruction Manual
Contents
Installation 3
MSC-3 mounting location 3
CAUTION Installation Information 3
MSC-3 Mechanical Installation Information 4
MSC-3 Power wiring for 3 Phase supply 9
Basic power wiring diagram 9
Supply circuit protection and switchgear 9
Cable sizes 9
Electrical Isolation 9
Fuse Circuit Breaker Ratings for All MSC-3 Models 10
Motor thermal protection 10
MSC-3 Power wiring for Single Phase Supply 11
MSC-3 with a DC Supply 12
Installation practices for Electromagnetic Compatibility (EMC) compliance 13
Installation practices for EMC compliance 13
Wiring materials for EMC compliance 13
Control connections and conguration 19
General 19
Factory default settings 19
Settings for your application 19
Quick Setup 19
Industrial Terminals Typical Connection Diagram – Terminal Cong 1 20
General 20
Quick Setup for Terminal Cong 1. 21
Quick Setup for Terminal Cong 4. 26
HVAC Terminals Typical Connection Diagram – Terminal Cong 3 32
General 32
Application: Supply air or smoke spill fan 36
Application: Return air fan 37
Application: Stair pressurisation fan with internal PID 38
Application: Stair pressurisation fan with external PID 40
Application: Cooling tower fan with reverse acting internal PID 41
EIA/RS-485 Communications Wiring 43
Best practice 43
Terminating resistors 43
General 44
Shortcuts 44
Extended Features Option Wiring 45
MSC-3 Start Up 47
Run Display 48
Meter Display 49

IM00120
vi
IM00120
Contents
Menus 49
Major Features 50
Motor Speed Ramp 50
Dual Ramps 51
Essential Services Override 51
Minimum Speed Idle Function 52
Line Contactor Start Control 53
Reference Selector 55
User References 55
Analogue Inputs and Spanning 56
Extended Feature Option Cards 57
Extended Feature Analogue Output 57
P.I.D. Controller 58
PID Setup Checklist and Tuning 59
PID Application Examples 61
Application: Stair pressurisation fan with internal PID 61
Application: Cooling tower fan with reverse acting internal PID 61
Application: Water pumping with automatic pressure control 61
Communications 62
EIA/RS-485 Communication Indicator 62
BACnet MS/TP 62
BACnet Services Supported 62
Data Link Layer 62
MAC ID / Device Object Instance 62
BACnet Set-up and Operation 63
Local mode 63
Remote mode 63
Reset 63
Network Speed Reference 63
Essential services operation (ESO) 63
Local / remote mode selection 63
BACnet Quick Set-up Guide 63
BACnet Status Indicators 64
MODBUS RTU (EIA/RS-485) 64
MODBUS Memory Model 64
Supported MODBUS Function Codes 64
MODBUS Exceptions 64
MODBUS Setup and Operation 65
Local mode 65
Remote mode 65
Reset 65
Network Speed Reference 65

IM00120
vii
IM00120
MSC-3 Instruction Manual
Essential services operation (ESO) 65
Local / remote mode selection 65
MODBUS Quick Set-up Guide 65
MODBUS Status Indicators 66
A00 DEFAULTS Menu 66
A01 Menu Lock 66
Menu Lock Code Entry 66
A02 Def. Display 67
Meter Display 67
A03 Run Display 67
A030 Run Display Format 68
A031 Run Display Scale 68
A032 Run Display Units 68
Load Factory Defaults? 69
Load Custom Defaults? 69
Save Custom Defaults? 70
Upload/Download Connection 70
B00 MOTOR Menu 70
B01 MOTOR VOLTS 71
B02 MOTOR AMPS 71
B03 MOTOR Hz 71
B04 MOTOR RPM 72
C00 PERFORMANCE Menu 72
C01 MINIMUM Hz 72
C010 MIN Hz 72
C011 IDLE DELAY 73
C012 RESUME Hz 73
C02 MAX Hz 73
C03 RAMP 74
C030 ACCEL TIME 74
C031 DECEL TIME 74
C032 S TIME 74
C033 DUAL RAMP 75
C034 ESO RAMP 75
C04 FLUX PLUS 76
C040 FLUX PLUS 76
C041 HiSpd Flux+ 76
C05 SLIP COMP % 77
C06 AUDIBLE FREQ 77
D00 PROTECTION Menu 77
D01 CURRENT LIM 78
D02 I2t 78

IM00120
viii
IM00120
Contents
D020 I2t 79
D021 I2t zero Hz 79
D022 I2t CNR Hz 79
D03 REVERSE 80
D04 DC INPUT 80
D05 1 Phase Inpt 80
D06 SKIP SPEED 80
D060 SKIP SPEED 81
D061 SKIP RANGE 81
E00 STOP/START Menu 82
E01 COAST STOP 82
E02 DYNAMIC BRK 82
E03 AUTO RESTART 82
E030 ARs ALLOWED 83
E031 AR CLR TIME 83
E04 Reset by PF 83
E05 Motor Resync 84
E06 LC CONTROL 84
F00 REFERENCES Menu 84
F01 REMOTE 85
F02 LOCAL 85
F03 ESO 86
F04 JOGFWD 86
F05 JOG REV 86
F06 USER REF 1 and F07 USER REF 2 86
F08 CONSOLE CFG 87
F080 PERSISTENT 87
F081 STOP RESET 87
F09 COMMS PRESET 88
F10 PRESETS 88
F100 PRESET1 to F107 PRESET8 88
G00 INPUT/OUTPUT Menu 89
G01 Inpt fxn CFG 89
Duplicate Selections 90
I00 FWD & LATCH 91
I01 REV & LATCH 91
I02 ~STOP 91
I03 FWD 91
I04 REV 92
I05 UP 92
I06 DOWN 92
I07 RESET 92
Autres manuels pour MSC-3
3
Table des matières
Autres manuels Zener Contrôleurs