Yolin YLBP Manuel utilisateur

User’s Manual
Note: Please read this manual carefully before using the
product and properly keep. This machine will produce
noise above 75dB while working, please pay attention
to protection. The pump and air tube will produce high
temperature when working continuously for a long
time, please use after cooling. Children are not allowed
to use this product.

Accessories
Product Introduction
Component description
High-pressure Tube
Cooling hole
Light
“ ”Power
“-”Key
“+”Key
Display screen
“M”Start/Stop Key
Air tube connector
Charging Port
Schrader Valve
Charging Line ×1 Storage Bag ×1
French valve Adapter X 1 Gas Pin X 1 Multifunction Valve X 1

Note: The product, accessories and user interface in the manual
are schematic diagrams for reference only. Due to the product
upgrading, there may be some differences between the product and
the schematic diagrams. Please subject to the real product.

Use Guide
1. Air tube installation
Install the high-press tube at tighten the tube
2. Power on
3. Preset inflation pressure
Mode switch
Press and hold the on / off
button to start, The air pump
automatically shut down
without any operation in 3
minutes in power on state.
Press “On/Off” button can be switched
between the following five scenarios.
Please select the correct air press unit
before inflation.
No mode light on: The preset pressure
can be adjusted freely. Press and hold
“-”key can switch between psi/bar
(the value and unit can be memorized)
Adjustable range:3-150psi
Bicycle mode light on:Default 45 psi
Adjustable range:30-65psi
A
Motorcycle mode light on:Default 2.4bar
Adjustable range:1.8-3.0bar
Automobile mode light on:Default 2.5bar
Adjustable range:1.8-3.5bar
Ball mode light on:Default 8 psi
Adjustable range:4-16psi

When the battery displays fully lit,
it is fully charged. E flashing
indicates battery low, It can be
used after recharged. Don't use the
product when charging
preset value adjustment
4. Inflation
Start inflation
Stop inflation
5. Battery and charging
Select a profile, press “+”or “-”
to adjust preset value.
When adjusting the preset pressure
value, the digital flashing indicates
the target pressure adjustment status,
long digital light indicates real-time
pressure.
Press “M”tart inflation. Digital
displays real-time tire pressure
during inflation. 75-80 dB noise will
be generated during inflation, please
pay attention to protect. The pump and
air tube will generate high
temperature when working continuously
for a long time, please avoid
prolonged touching with hands.
The air pressure reaches the preset
value, the pump will stop inflation
automatically. Press any key to stop
inflation during inflation.

6. Screw off the valve
The temperature of tube is relatively high after
inflation. Be careful burns when screwing off the valve.
There will be slight air leakage when disassembly.
Please remove it as quick as possible to reduce the air
leakage.
7. Power off
Press and hold the “On/Off”button to shut down.
The air pump automatically shut down without any
operation in 3 minutes in power on state.
8. Connection of various types of valve
French valve adapter
Valve type
Connector
French valve will be used
for road cycling and
specific mountain cycling
Inflation: Loosen the
screw of French valve
adapter to inflation.
Deflation: Loosen the
screw of French valve and
press the screw to deflate

Air Needle
American valve
Valve
type
Connector
Valve
type
Connector
Basketball, football and
other balls need to use air
needle to inflation.
Inflation: tighten the air
needle and American valve
and insert into the filling
pore to inflation.
Deflation: Insert the air
needle in to the filling
pore to deflation
Mountain cycling, electric
bicycle, motorbike, automobile
will be equipped American
valve.
Inflation: American valve can
be directly connected to
inflate.
Deflation: Press the air needle
inside the valve with a
suitable tool to deflate.

Multifunctional valve
Valve
type
Connector
9. Pressure examination
Connecting with air tube, digital displays real-time
pressure in power on state.
10. Inflation pressure check
To ensure safety, please check the required inflation
pressure of the inflated items by reading the manual
before inflation.
Ball
The multifunctional valve
will be used for inflatable
cushion, inflatable boat
and balloon for inflation.
Inflation: Tighten the
multifunctional valve and
American valve and insert
into the filling pore to
inflate.
Deflation: insert the
multifunctional valve into
the filling pore to
deflate.
The inflation pressure of
football, basketball and
volleyball will be marked
around the valve.

Tire pressure
Special reminder
The inflation pressure of balloon, toy ball, swimming
circle and other products is lower than the range of
inflation pump, so it can't stop inflation
automatically by preset pressure. Please use with
caution.
Safety and protection
■stuck/high current protection: When there is a
foreign body inside sticking the motor gear or the motor
current is too high, the screen will display E21. The
pump will resume normal after clearing the foreign body
and reset or reset directly.
The tolerable range of
tire pressure of
automobile, bicycle and
motorcycle are marked on
the sidewall of the tires.
The guide pressure of the
tire is marked near the
inner wall of the driver's
side door.The inflation
pressure is related to the
load weight. For more
detailed air pressure
suggestions, please refer
to the vehicle manual.

■Battery over discharge protection: When the battery
is over discharged during inflation, the machine will
start the over discharge protection, and the screen will
display E22, restart or restart after charging will
return to normal
■High temperature protection: When the internal
temperature of the body is too high, the high
temperature protection mechanism will be activated, the
screen displays E23. After the temperature drops to the
safe temperature, restart and return to normal.
■Inflation duration protection: After working at 25 ℃
for about 18 minutes, the inflation will stop
automatically and the screen displays E25. restart and
return to normal.
■Charing temperature protection: In the process of
charging, when the lamp is on, it will enter into the
charging temperature protection. When the temperature
of standby is maintained at 0 ℃~ 45 ℃, it can be
charged normally. During the charging process, the lamp
will go out automatically.
Table des matières
Manuels Pompe à eau populaires d'autres marques

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guide de dépannage

DUROMAX
DUROMAX XP WX Series Manuel utilisateur

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuel utilisateur

Franklin Electric
Franklin Electric IPS Manuel utilisateur

Xylem
Xylem e-1532 Series Manuel utilisateur

Milton Roy
Milton Roy PRIMEROYAL Manuel utilisateur











