YOKOGAWA TB820D Manuel utilisateur

Technical
Information
FLEXA, FLXA and SENCOM are trademarks or registered trademarks of Yokogawa Electric Corporation.
All other company and product names mentioned in this user’s manual are trademarks or registered trademarks of their respective companies.
We do not use TM or ® mark to indicate those trademarks or registered trademarks in this user’s manual.
TB820D, TB830D
Sampling System Selection
Manual
TI 12E01B30-01EN
TI 12E01B30-01EN
©Copyright Oct. 2022
3rd Edition Mar. 2023
CONTENTS
Introduction .............................................................................................................2
1 Dimensions ...................................................................................................3
1.1 TB820D Dimensions ............................................................................................ 3
1.2 TB830D Dimensions ............................................................................................ 6
2.
Installation .................................................................................................... 16
3. Piping.......................................................................................................... 17
3.1 TB820D (-NN, -A5) Piping .................................................................................. 17
3.1.1 Head tank and Piping Parts ................................................................ 27
3.1.2 System without a Head Tank .............................................................. 31
3.2 TB830D (-NN, -A5) Piping .................................................................................. 32
3.2.1 Piping type .......................................................................................... 33
3.2.2 Head tank............................................................................................ 34
4. Wiring.......................................................................................................... 35
4.1 TB820D wiring .................................................................................................... 35
4.1.1 SENCOM cable for turbidity and chlorine (A) ..................................... 39
4.1.2 Power cable for FLXA402T (B)........................................................... 39
4.1.3 Power supply cable (C)....................................................................... 39
4.1.4 Wiring with PG400 .............................................................................. 40
4.1.5 When Relay box for solenoid valve is included .................................. 40
4.2 TB830D Wiring.................................................................................................... 44
4.2.1 SENCOM cable for Turbidity/Chlorine (A) .......................................... 47
4.2.2 FLXA402T power supply cable (B)..................................................... 47
4.2.3
TB830D power supply cable (C), Relay box power supply cable (D)
........... 47
4.2.4 Power supply cable (E) ....................................................................... 47
4.2.5
Without a sampling system and with a Relay box for solenoid valve
............ 51
5 Zero Turbidity Filter................................................................................... 54
6 Operation.................................................................................................... 55
6.1 TB820D Supplying a Sample and Adjusting the Flow Rate .......................... 55
6.2 TB830D Preparation for Operation .................................................................. 56
7. Automatic cleaning/Automatic zero calibration Sequence.................. 58
7.1 TB820D Sequence ............................................................................................. 58
7.2 TB830D Sequence ............................................................................................. 60
Revision Information ........................................................................................... 62

2
TI 12E01B30-01EN
TB820D and TB830D Sampling System Selection Manual
Introduction
This manual describes how to select a sampling system when the analyzer combined with the
“TB820D Right Angle Scattered Light Turbidity Detector” and “TB830D Surface Scattering Light
Turbidity Detector” does not have an assemble stanchion.
If you specify without a sampling device (Sux code -NN, -A5), you have to select and build
system components such as a head tank, solenoid valve, and manual valve. This document
describes how to select the solenoid valves and head tanks necessary for conguring a sampling
system, as well as piping and wiring diagrams.
Media No. TI 12E01B30-01EN 3rd Edition : Mar. 2023 (YK)
All Rights Reserved Copyright © 2022, Yokogawa Electric Corporation

TB820D and TB830D Sampling System Selection Manual 3
TI 12E01B30-01EN
1 Dimensions
1.1 TB820D Dimensions
Top cover
Detection unit Flow cell
Smart unit
Smart unit cover
Front cover
sample outlet
LED
sample inletDrain
Fuse
Figure 1 TB820D part name
Nov.22,2012-00

TB820D and TB830D Sampling System Selection Manual 4
TI 12E01B30-01EN
sample outlet
Rc1/2 or 1/2NPT
Ultrasonic oscillator
(for oscillator) wiring port
Cleaning controller
sample inlet
Rc1/2 or 1/2NPT
Drain
Rc1/2 or 1/2NPT
For wall mounting
(4-M5 screws)
87
368
45
56
174
200
500
or more
500
or more
Maintenance space
200
or more
250
or more
(368) (261)
(275)
261
Unit: mm
54 100
100
2-R3
2-R3
160
Figure 2 TB820D Dimensions
Nov.22,2012-00

TB820D and TB830D Sampling System Selection Manual 5
TI 12E01B30-01EN
nInstallation Dimensions
Install the TB820D’s detector unit in pipes or walls using their special mounting brackets,
respectively. Note that these mounting brackets are supplied only when specied.
lPipe Mounting (Option Code “/U”)
For information on the converter, read FLXA402T IM.
54 141
128 Unit: mm
Mounting 2-inch pipe
(ø60.5)
Figure 3 Diagram of TB820D Pipe Mounting
lWall Mounting (Install the detector with four M5 screws)
For information on the converter, read FLXA402T IM.
100
2-R3
2-R3
160
Unit: mm
Figure 4 Diagram of TB820D Wall Mounting
nConduit adaptor (/CB3, /CD3, /CF3)
G1/2 (/CB3), 1/2NPT (/CD3), M20x1.5 (/CF3)
Adapter
45
(1.77)
Approx.55
(2.17)
Cable gland
for adapter
Case Unit: mm
(inch)
Figure 5 Diagram of TB820D conduit adopter

TB820D and TB830D Sampling System Selection Manual 6
TI 12E01B30-01EN
1.2 TB830D Dimensions
●Without sampling system (-NN, -A5) Unit: mm
246
208
142
296
50
38
14.5
100
56
(22) 150
4-ø4.2 hole
4-ø6.2 hole
Figure 6 TB830D-NN, -A5 Dimensions
lMaintenance space
250 or more
250 or more
Unit: mm
500 or more
250 or more
Maintenance space
Maintenance space
Maintenance space
Maintenance space
Figure 7 TB830D maintenance space

TB820D and TB830D Sampling System Selection Manual 7
TI 12E01B30-01EN
lPipe mounting hardware (/U) for -NN, -A5 Without sampling system Unit: mm
208 (140)
(215)
150
(22)
56
70
100
38 35
157
203
4-ø10
4-M5
Panel mounting
hardware: /U
Pipe 50A
(or 2B)
U-Bolt
Approx. 372
Figure 8 Pipe mounting hardware (/U) for -NN, -A5
lRack or wall mounting hardware (/R) for -NN, -A5 Without sampling system Unit: mm
166 25(22)
56
190
220
38
105
125
3-ø6.2
ø10
4-M5 18
Approx. 295
Rack or wall mounting
hardware: /R
Figure 9 Rack or wall mounting hardware (/R) for -NN, -A5

TB820D and TB830D Sampling System Selection Manual 8
TI 12E01B30-01EN
nOther Dimensions
lTerminal box A Unit: mm
Terminal box A is supplied when “/ARS” option code is specied.
Terminal box A can be connected to the pipe when “/C□” option code is specied.
275
203
9211
(12)
70
75
17
Figure 10 Terminal box A dimensions
lInstallation of pipe mounting hardware (/U) on the terminal box A
275
203
(24)
(52)
92 1070
(22)
70
100
75 35
142
200
60
17
277
2-ø9
4-M5
Panel mounting
hardware: /U Panel mounting
hardware: /U
Pipe 50A
(or 2B)
U-Bolt
Figure 11 Installation of pipe mounting hardware (/U) on the terminal box A
lInstallation of rack or wall mounting hardware (/R) on the terminal box A
4-ø6.5
275
203
30
92
11
70
110
130
75 10
130
160
17
235
4-M5
Panel mounting
hardware: /R
Figure 12 Installation of rack or wall mounting hardware (/R) on the terminal box A

TB820D and TB830D Sampling System Selection Manual 9
TI 12E01B30-01EN
lTerminal box B Unit: mm
Terminal box B is supplied with the product in the following cases.
• When both Sampling system “-NN” and Option “/C□” (Conduit adapter) are specied, but “/
ARS” (with Arrester) is not specied.
• When Sampling system “-A1” is specied but “/ARS” (with Arrester) is not specied.
• When Sampling system “-A2” or “-A3” is specied and Option “/PH□2” or “/PH□7” or “/FC” is
specied, but “/ARS” (with Arrester) is not specied.
Terminal box B can be conduit wired.
132 66
(31)
144
(31)
114.1
23.3
2-M4
Figure 13 Terminal box B Dimensions
lInstallation of pipe mounting hardware (/U) on the terminal box B
96
27
90 15
100
114
140
56
4 66 (59)
132.5
(28)
2-ø9
2-M4
143.5
216.5
60
73
Panel mounting
hardware: /U
Panel mounting
hardware: /U
Pipe 50A
(or 2B)
U-Bolt
Figure 14 Installation of pipe mounting hardware (/U) on the terminal box B

TB820D and TB830D Sampling System Selection Manual 10
TI 12E01B30-01EN
lInstallation of rack or wall mounting hardware (/R) on the terminal box B Unit: mm
132.5
143.5
4 66
20
216.5
70
60
27
90
90
114
140
2-ø10 2-ø5.5
2-M4
20
30
73
Panel mounting
hardware: /R
Figure 15 Installation of rack or wall mounting hardware (/R) on the terminal box B
lRelay box
A relay box is supplied with the product when “-A2”, “-A3”, or “-A5” is specied. A relay box is
used to drive the solenoid valve for automatic cleaning/automatic zero calibration. Select /C□
(conduit adapter) to provide conduit wiring to the relay box.
165
165
168.5
158.5
40
80
80 4-M6
Figure 16 Relay box Dimensions
Autres manuels pour TB820D
2
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels YOKOGAWA Capteur de sécurité