WILMS KT 580 Manuel utilisateur

Perfection is our aim
Manual
Dehumidifiers
KT 580

Overview
This manual covers Wilms Dehumidifier type:
Warning It is the responsibility of the operator to read and understand this service manual
and to use the correct operating procedures.
Read the entire manual before the initial start-up of the dehumidifier. It is important to
know the correct operating procedure for the unit and all safety precautions to prevent
the possibility of property damage and/or personal injury.
Contents This service manual covers the following main topics:
Page
Introduction / Overview 1
General information / EU-Conformity Declaration 2
General warnings 3
Product- and functional description 4 - 6
Set up and transport of the unit 7 - 10
Operating manual 11 - 16
Accessories 17
Preventive maintenance 18 - 24
Fault finding and solving 25
Technical data 26
Measurements 27
Disposal 28 - 29
Wiring diagram 30
Spare parts 31
Exloded view KT 580 32
1 of 32
Introduction
Topic
KT 580, Article number 3105800

General Information
Introduction: This section gives the general information about this service manual and about the unit.
Target Group: The target group for this service manual are the technicians who install, maintain, and
exchange parts on the units.
Copyright Copying of this service manual, or part of it, is forbidden without prior written
permission from Hans Wilms GmbH & Co. KG – Erftstrasse 34 – 41238 Mönchengladbach.
Reservations: Hans Wilms GmbH & Co. KG reserves the right to make changes and alterations to the
product and the service manual at any time without prior notice or obligation.
EU-
Conformity
Declaration:
Dehumidifier, Type KT 580
covered by this declaration, is in conformity with the following directives:
2006/42/EG Directive on the Safety of Machines
2014/30/EU EMC Directive
1907/2006/EG Reach Regulation
2011/65/EU RoHs-Guidline (electric- and electronic cold devices)
as well as in accordance with the following harmonized standards:
DS /EN 12100:2010 Safety of machines
EN 60335-1:2012 Safety of electrical appliances for use at home or similar purposes
EN 60335-2-40: 2003 Safety of electrical appliances for use at home or similar purposes
EN 378-1:2016 Refrigerating systems and heat pumps - Part 1
EN 378-2:2016 Refrigerating systems and heat pumps - Part 2
Moenchengladbach, 28.07.2021
Place - Date Signature Managing Director
2 of 32
Hans Wilms GmbH & Co. KG - Erftstr. 34 - 41238 Moenchengladbach- hereby declares that the
unit mentioned below:
Jochen Wilms

General warnings
Warning:
The dehumidifiers contain a flammable refrigerant. Take the following precautions,
to avoid any danger
Attention
•Please note that refrigerants may not have an odour.
Site requirements (installation and storage):
•The device must be installed, operated and stored in a room with a floor
area greater than 4 m². Check if there are any local regulations that you
have to observe when installing or storing the device.
•The device must be installed in a room without a permanently active ignition
source (for example: open fire, a gas device or electric air-heater in operation).
•Keep the ventilation openings free of foreign objects during operation.
Actions to be avoided (operation and handling)
•Be extra careful when handling the device so as not to cause damage
that can lead to a leak in the cooling circuit.
•Use to speed up the defrosting process or to clean
no other means recommended by the manufacturer.
•Do not drill or press with an open flame.
In case of fire:
•A fire can produce toxic fumes. In case of fire
therefore, you need to leave the room as soon as possible.
3 of 32

Product- and functional description
Introduction: This section will give you a description of the machines type KT 580
and the functions:
Important: The length of the 100 mm connection hoses (accessories) for the model
KT 580 may be not more than 7.6 metres per tube.
Principles of The following describes the air flow
operation: through the dehumidifier:
The air flow through the
dehumidifier.
A fan draws in humid air through a
filter to the dehumidifier
The air is cooled down and
humidity/water drops are led down
to the water tank
The air is re-heated by e.g. the
operation of the dehumidifier (approx.
increase in temperature is + 5 °C)
Due to the repeated air circulation through the dehumidifiers, the air humidity is
continuously reduced whereby achieving rapid, but gentle drying.
The dehumidifier can be operated continuously or controlled by a built-in hygrostat.
Illustration: This illustration gives an overview of the dehumidifier:
Handle
Touchscreen
Cover
Power cable
Supply air inlet (PPI
filter behind the grille)
Air outlet Serial plate
Wheel
Water tank
the water tank
Rear view Front view
4 of 32

Product- and functional description
Hose
connection: With two hoses connected to the outlets (2 x 100 mm Ø):
Dry, warm air can be directed for example under a floor.
Hans Wilms GmbH & Co. KG recommends maximum 7.6 metres
hose per air outlet.
Heating
element: The KT 580 has a built-in heating element with 1 kW. If the dehumidification process
should be speeded up, the heating element can be activated, and this increases the
outlet temperature. See manual, page 9 for Activation of the heating element.
Water tank: Water is collected in the water tank. Alternatively, you can also setup the dehumidifier for
permanent drainage with the adapter for hose connection (accessories, see page 17).
When the water tank is full, the dehumidifiers shut off automatically.
Emptying of the water tank, see manual, page 16.
Operation of the unit is not possible once the water tank is removed.
Product- and functional description
Illustration: This illustrates the operator control:
Display/
Operator Control
Display
Function buttons
Status display
Main switch
Fig. 4
5 of 32

Product- and functional description
Functions: Main functions
• Manual or automatic operation (built-in adjustable hygrostat)
• Socket for external hygrostat
• Display for temperature, relative humidity, hour meter and kW/h-consumption
• Hour meter and display for consumed kW/h without 230V-connection
• Adjustable service interval counter
• Providing additional heat for higher dehumidification efficiency
• Targeted dehumidification, e.g. between floor pads
For correct operation look at the detailed instructions in this manual.
Cooling
Circuit
Diagram:
Pos. Description
1 Compressor
2 Condenser
3Fan
4 Filter
6 Vaporizer
7 Solenoid valve
8 Thermic expansion valve
6 of 32

Set up and transport of the unit
Introduction: This section provides information required for:
unwrapping the unit, making it ready for use and transportation of the unit.
Warning: If the dehumidifier has been laid down during transport, it is imperative to place it in
upright position for at least one hour before put into service!!!
Procedure: Follow these steps to unwrap the unit and make it ready for use:
Step Action Illustration
1 Open the cardboard box
on the top.
2 Place the cardboard box so
that the handle and wheels
are on the floor.
3 Pull the handle and wheel
of the dehumidifier out while
lying down.
4 Loosen the finger screws
and pull the handle up to the
desired height and tighten
the finger screws again.
5 Remove the protective film from the control panel.
Placing: Placement of the dehumidifier
Place the dehumidifier at a spot with good air circulation, where the minimum distance
from the air intake side should be 60 cm to the wall and from the air outlet side 3 m
if there are no flexible hoses.
7 of 32

Set up and transport of the unit
Location Since the appliances contain a flammable refrigerant, the following requirements for
requirements:
the location must be fulfilled.
•The device must be installed, operated
and stored in a room with a area larger
than 4 m².
Check whether there are any local regulations
that you have to obey when installing
or storing of the device.
•The device must be stored in a well-ventilated area, with the
room size must correspond to the room areas of 4 m².
•The device must be installed in a room without permanently
active ignition sources (e.g. open fire, a gas appliance in operation or an
electric air heater in operation).
Optimal Make sure that the room to be dehumidified is closed and the device is not
operation: placed near a heat source, such as e.g. a radiator.
Electrical The dehumidifier is complete with a cable and plug and ready for connection to a
connection: 230 V / 50 Hz socket. Protect the socket with a 10 A fuse or a 16 A circuit breaker.
Warning: If the power cord is damaged, it must be replaced by the manufacturer,
maintenance service or similarly qualified persons in order to avoid danger.
8 of 32

Set up and transport of the unit
Stairs: The wheels are mounted so that the unit can easily be pulled upstairs without damaging
the housing or the stairs.
Transport/- The dehumidifier can be lifted by two persons or with a crane, see instructions below:
Replacing
of the
dehumidifier:
Proceed as follows:
Hoist/Crane
Lift by lifting strap.
Note: Observe local working environment rules regarding heavy lifting!
9 of 32
2 People
Ce manuel convient aux modèles suivants
1
Table des matières
Autres manuels WILMS Déshumidificateur