Wildwood E-1 Series Fiche technique

IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
File # MH60821
ANSI Z21.17/CSA 2.7
Conversion Burner
CONVERSION GAS BURNER
for Refractory Ovens
OPERATION AND INSTALLATION MANUAL
AUTOMATIC SERIES: E-1 / E-2 / E-3
For future reference write the model and serial numbers here :
Model #: E—_____ Serial # :__________________________
They are on the label axed to the burner
Safety and General Instrucons…...…….…….…..…1-4
Technical informaon..……………………….………….……5
Installaon Instrucons………………….…………………6-8
Operang Instrucons
Control panel…………………..……… ….……….9-11
Starng and Operang burner…………….11-14
Cleaning and Maintenance………...……….14-15
Troubleshoong………….……………..……….16-17
Removal and Disposal……………..…..……….....18
Electrical Connecons...…………..…..……….….....19-20
Parts List……… ……..…………..………..……….…......21-22
Parts Diagrams…...…….…….………………………...…23-26
Warranty…………………………………………………….……..27
Burner Dimensions…….…….………………………..…28-31
Contact Informaon.…….………………………………..…32
Symbols Used in the Manual
Warning
This is the safety alert symbol. This symbol alerts you to potenal hazards that can kill or hurt you
and others.
Danger
Indicates the risk situaons for the burner and/or the product while operang.
Note well
Indicates informaon of interest in the manual and for the proper operaon of the burner
Qualied technician
Indicates the procedures for installaon, maintenance or adjustments that are strictly to personnel
of the manufacturer, the Technical Service Center or qualied technicians.
CONTENTS

2
WARNING! If the informaon in these instrucons is not followed exactly, a re
or explosion may result, causing property damage, personal injury or death
Do not store or use gasoline or other am-
mable vapors and liquids in the vicinity of
this or any other appliance.
Installaon and service must be performed
by a qualied installer, service agency or
the gas supplier.
Do not try to light a match, or cigaree, or
turn on any gas appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Clear the room, building or area of all occu-
pants.
Immediately call a gas supplier from a
neighbor's phone. Follow the gas supplier's
instrucons.
If you cannot reach your gas supplier, call
the re department.
WHAT TO DO IF YOU SMELL GAS:
AVERTISSEMENT! Si les renseignements dans ce manuel ne sont pas
exactement observés, un incendie ou une explosion peut survenir, causant des
Ne pas entreposer ni uliser de l’essence ou
d’autres vapeurs ou liquides inammables à
proximité de cet appareil ou de tout autre
appareil électroménager.
L’installaon et l’entreen doivent être
eectués par un installateur qualié, une
agence de service ou le fournisseur de gaz.
Ne pas tenter d’allumer un appareil.
Ne pas toucher à un commutateur élec-
trique.
Ne pas uliser le téléphone se trouvant sur
les lieux.
Appeler immédiatement le fournisseur de
gaz à parr du téléphone d'un voisin. Suivre
ses instrucons.
À défaut de joindre votre fournisseur de gaz,
appeler les pompiers.
QUE FAIRE DANS LE CAS D’UNE ODEUR DE GAZ :

3
Read this before you begin installaon:
The installaon must conform with local codes or, in the absence of local codes, with the
Standard for the Installaon of Domesc Gas Conversion Burners, ANSI Z21.8, and the Na-
onal Fuel Gas Code, ANSI /223.1, or the CAN/M-13149, Installaon Codes.
The appropriate burner size should be selected according to the burner sizing chart.
Do not allow unauthorized personnel to work on the burner.
The burner must only be incorporated into an oven of a domed structure constructed of
refractory clay or rebrick as a heang appliance for the oven.
The burner must be protected from air movement of more than 3 mph.
In order to avoid variances in pressure, the burner must draw air from the same source as
the oven chamber.
The burner may not be started or operated unless fully and correctly installed.
The appliance must be installed in a well venlated place. For proper combuson a
minimum area of 4 square feet is required in area below burner.
If ammable panels used for lining, use insulang material and strictly respect the
venlaon in the upper surfaces. Parts sealed by the manufacturer or its agent cannot be
adjusted by the installer and the user
Vamparossa reserves the right to update the producon and manuals without having to up-
grade the producon and previous manuals. Customer service is available to provide upon
request, informaon about updates Vamparossa has made on burners.
You'll receive these parts:
Burner
Flange with sleeve
Control box 110v
Transformer 110v to 220v
Regulator Pietro Fiorenno F30051
Adapter
For installaon you'll need these tools:
Heavy duty drill
Core bit for sleeve
Drill bit for xing screws
Fixing screws (self-tapping or anchor bolts)
Screwdriver and adjustable wrench
PFTE tape
Reciprocang saw
Ensure the burner you select is the right size for your oven:
24" 28" 32" 36" 40" 44" 48" 52" 56" 60" 64" 68" 72"
E-1
E-2
E-3

4
CAUTION:
•Always ensure the burner is protected from wind speeds in excess of 3mph.
•The air intake for the burner must always be at the front of the oven assembly.
•The area of the air intake shall be not less than 384 square inches.
INCORRECT INSTALLATION
CORRECT INSTALLATION

5
Technical Informaon and Sengs
Adjust air intake
To adjust air intake loosen screw V and increase or
decrease gap H.
Conversion to alternave gas type
To be carried out by a qualied technician
•Loosen the screw V and slide the bushing
•Slide the brass bushing Z.
•Unscrew and replace the nozzle 7-8 for the new type of
gas.
•Ax an indelible adhesive data plate with the new
conguraon.
•Restore the seals of paint on the set.
•Carry out the appropriate gas leakproof tests.
Natural Gas
Burner
Nozzle
mm
Burner
Air gap
mm
Inlet pressure
WC/Mbar
Manifold pres-
sure WC/Mbar BTU Max Consumpon Max/Min
E-13.4 77/17.45 4/10 53,981 1.668/0.781 m3/h
E-22.6 77/17.45 4/10 64,796 1.896/0.912 m3/h
E-32.6 87/17.45 4/10 93,331 2.76/1.332 m3/h
LPG
Burner
Nozzle
mm
Burner
Air gap
mm
Inlet pressure
WC/Mbar
Manifold pres-
sure WC/Mbar BTU Max Consumpon Max/Min
E-12.2 811/27.40 10/ 24.90 53,318 2.52/1.29 Kg/h
E-21.7 811/27.40 10/ 24.90 67,753 3.19/1.45 Kg/h
E-31.7 811/27.40 10/ 24.90 98,367 4.64/2.29 Kg/h

6
Step 1 Using a core bit, create the hole for the sleeve from oven base to oor of oven,
either at A (“10 o’clock”)or B (“2 o’clock”) locaons. The edge of hole should be
2” from the side wall, and approximately 4” back from the widest diameter .
Tip: If a suitable core bit is not available, a small bore drill can be sued to create a series of
holes around the perimeter of the hole.
Step 2 Align the ange with the hole A or B on the underside of the oven and aach us-
ing self-tapping screws that have been provided.
Step 3 Slide burner into ange and swivel it so the tubes are oriented towards the front
of the oven base.
Step 4 Adjust burner so the sleeve protrudes 1/2” above the oor. Tighten sleeve clamp
Step 5 Mount the control box so that the burner inside the oven is visible when oper-
ang the control. You have dierent choices for mounng the controller. For ex-
ample, either:
•build it into the base so that the face of the control box is ush with the
base, or
•aach brackets to the underside of the oven (in wood storage area) and
aach controller to brackets
Step 6 Mark a point 8” above the deck, diagonally opposite the burner.
Using a masonry bit drill a 1/4” hole through the oven wall. Insert the probe un-
l the p protrudes 1/2” into the oven.
SEE NEXT PAGE FOR DIAGRAM
Step 7 Aach 1/2” gas line and thermocouple wire.
Step 8 Aach main gas line with inline regulator. Read instrucons that accompany the
regulator to ensure proper installaon.
Installaon Instrucons

7
Placement of the probe

8
•If the burner is not installed properly, it may cause a re. To reduce the risk of re, follow the
installaon instrucons.
•The appliance must be installed in a well venlated place. Make sure the ow of air needed for
combuson is ensured by a minimum area of 0.5 m2 (in area below burner zone). In the case
of ammable panels used for lining, use insulang material and strictly respect the venlaon
in the upper surfaces
•All the electrical boards must be earthed with an earth wire of a suitable secon to protect the
operator in case of accidental contact between metal parts of the burner and the wires live or
components. The cables used to supply electrical power must be of a sucient size and the
insulaon must be suitable for the relave voltage and temperature of the equipment. Before
connecng the burner it is necessary to verify correct resistance, that the device is correctly
grounded with an earth wire, and that the earth wire of the connecon side is longer than the
other wires. Never disconnect the yellow/green earth cable device. The control must be in-
stalled near the burner, and must have a capacity suitable to the burner electrical input (See
the technical characteriscs). For these values please read the general specicaons of the gas
burner for the max. power input. To prevent re hazards install only fuses of a suitable size and
Secon of typical installaon:
ELECTRICAL CONNECTION
ALL THE ELECTRICAL CONNECTIONS TO THE MAINS NETWORK SHOULD BE DONE WITH THE POWER TURNED
OFF AND BY QUALIFIED AND AUTHORISED ELECTRICIANS AND IN ANY CASE ALWAYS IN FULL COMPLIANCE
WITH THE CURRENT REGULATIONS.
Before ignion take these precauons
Installaon instrucons connued

9
with the exact voltage rang.
•The user must ensure that the installaon complies with the local regulaons in force. The equipment should be
installed only by qualied personnel who must comply with the safety regulaons in force in the place of installaon.
Every ordinary maintenance operaon (for as the gas supply pipe) and maintenance (any adjustment to another gas)
must only be carried out by qualied persons.
•Before starng the burner make sure that nothing blocks the air ow to the burner and the burner's entry is not in
any way blocked.
•The burner may only be used with the gas specied on the name-plate unless the user follows wrien instrucons
from Vamparossa or its Authorized Agent on how to convert the burner to alternate gas for which the unit has been
tested.
•If necessary check inlet and manifold gas pressure using a pressure gauge . See Technical Informaon table for cor-
rect seng.
•The oven door must not be closed while the burner is in operaon
•The appliance and its individual shut-o valve must be disconnected from the gas supply piping system during
pressure tesng of that system when the test pressure is greater than 0.5 psi .
•Check that all gas taps are open, bleed the gas pipe if necessary.
•Consult the wiring diagram of the electrical board, if there is one, for the specicaons of the supplied power.
Before ignion take these precauons (connued)

10
BURNER IGNITION
Buon for switching the burner on and o
Funcon on/o
BURNER IGNITION IN AUTO MODE WITH THRESHOLD CONTROL t°.
Buon for inpung automac temperature control mode to achieve the set temperature
programmable by means of the + / - buons. In AUTO mode the message "AUTO" shows on the
mulfuncon screen. Press the + / - buons to increase or decrease the value of the temperature of
the burner. Temperature value is always visible on the display in the upper le .
MANUAL FLAME CONTROL FUNCTION.
Pressing the buon will acvate the MANUAL mode funcon. The "hand" symbol appears in the
upper le corner of the display. In this mode, manually adjust temperature using the + / - buons.
The intensity of the ame is indicated on the display by the lit bars.
Operang Instrucons
Control panel
Control funcons
Ce manuel convient aux modèles suivants
5
Table des matières